Instructions for use SMARTtorque S609 C - 1.008.1644 SMARTtorque Mini S605 C - 1.008.1645 SMARTtorque S608 C - 3.001.6560 Table of contents Table of contents 1 User instructions ........................ 4 2 Safety..........................6 2.1 Infection hazard ......................6 2.2 Technical condition......................6 2.3 Accessories and combination with other equipment ............
Instructions for use SMARTtorque S609 C - 1.008.1644 SMARTtorque Mini S605 C - 1.008.1645 SMARTtorque S608 C - 3.001.6560 1 User instructions 1 User instructions Dear User, Congratulations on purchasing this KaVo quality product. By following the in- structions below you will be able to work smoothly, economically and safely.
Page 5
Instructions for use SMARTtorque S609 C - 1.008.1644 SMARTtorque Mini S605 C - 1.008.1645 SMARTtorque S608 C - 3.001.6560 1 User instructions Serial number Legal Manufacturer CE mark according to Medical Devices Directive EC 93/42 Please note the electronic instructions for use...
Instructions for use SMARTtorque S609 C - 1.008.1644 SMARTtorque Mini S605 C - 1.008.1645 SMARTtorque S608 C - 3.001.6560 2 Safety | 2.1 Infection hazard 2 Safety The instructions for use are a component of the product and must be read care- fully prior to use and be accessible at all times.
Instructions for use SMARTtorque S609 C - 1.008.1644 SMARTtorque Mini S605 C - 1.008.1645 SMARTtorque S608 C - 3.001.6560 2 Safety | 2.3 Accessories and combination with other equipment 2.3 Accessories and combination with other equipment Use of un-authorized accessories on the device or un-authorized modifications to the device can lead to injury.
Instructions for use SMARTtorque S609 C - 1.008.1644 SMARTtorque Mini S605 C - 1.008.1645 SMARTtorque S608 C - 3.001.6560 3 Product description | 3.1 Intended use 3 Product description SMARTtorque S609 C (Mat. no. 1.008.1644) SMARTtorque Mini S605 C (Mat. no. 1.008.1645) SMARTtorque S608 C (Mat.
Instructions for use SMARTtorque S609 C - 1.008.1644 SMARTtorque Mini S605 C - 1.008.1645 SMARTtorque S608 C - 3.001.6560 3 Product description | 3.2 Technical Specifications Proper Use: According to these regulations, this product may only be used for the described application by a properly trained user.
Page 10
Instructions for use SMARTtorque S609 C - 1.008.1644 SMARTtorque Mini S605 C - 1.008.1645 SMARTtorque S608 C - 3.001.6560 3 Product description | 3.3 Transportation and storage conditions Relative humidity: 5% RH to 95% RH absence of condensation Air pressure: 700 hPa to 1060 hPa (10 psi to 15 psi)
Instructions for use SMARTtorque S609 C - 1.008.1644 SMARTtorque Mini S605 C - 1.008.1645 SMARTtorque S608 C - 3.001.6560 4 Startup and shut-down | 4.1 Checking the water quantity 4 Startup and shut-down WARNING Hazard from non-sterile products. Infection hazard for dentist and patient.
Page 12
Instructions for use SMARTtorque S609 C - 1.008.1644 SMARTtorque Mini S605 C - 1.008.1645 SMARTtorque S608 C - 3.001.6560 4 Startup and shut-down | 4.2 Checking the pressures SMARTtorque S609 C and SMARTtorque Mini S605 C: ▶ Insert the test gauge (Mat. no. 0.411.8731) between hose and medical device and check the following pressures: ð...
Instructions for use SMARTtorque S609 C - 1.008.1644 SMARTtorque Mini S605 C - 1.008.1645 SMARTtorque S608 C - 3.001.6560 5 Operation | 5.1 Attaching the medical device 5 Operation Note At the beginning of each workday, the water-conducting systems should be...
Instructions for use SMARTtorque S609 C - 1.008.1644 SMARTtorque Mini S605 C - 1.008.1645 SMARTtorque S608 C - 3.001.6560 5 Operation | 5.4 Removing the bur or diamond CAUTION Use of burs with worn or damaged shafts. Risk of injury, tool may fall out during treatment.
Page 15
Instructions for use SMARTtorque S609 C - 1.008.1644 SMARTtorque Mini S605 C - 1.008.1645 SMARTtorque S608 C - 3.001.6560 5 Operation | 5.4 Removing the bur or diamond ▶ After the bur has stopped rotating, firmly press the push-button with your thumb and simultaneously pull out the bur.
Instructions for use SMARTtorque S609 C - 1.008.1644 SMARTtorque Mini S605 C - 1.008.1645 SMARTtorque S608 C - 3.001.6560 6 Troubleshooting | 6.1 Cleaning the spray nozzle 6 Troubleshooting 6.1 Cleaning the spray nozzle WARNING Hazard from non-sterile products. Infection hazard for dentist and patient.
Instructions for use SMARTtorque S609 C - 1.008.1644 SMARTtorque Mini S605 C - 1.008.1645 SMARTtorque S608 C - 3.001.6560 7 Processing steps in accordance with ISO 17664 | 7.1 Preparations at the site of use 7 Processing steps in accordance with ISO 17664 7.1 Preparations at the site of use...
Instructions for use SMARTtorque S609 C - 1.008.1644 SMARTtorque Mini S605 C - 1.008.1645 SMARTtorque S608 C - 3.001.6560 7 Processing steps in accordance with ISO 17664 | 7.3 Automated processing 7.2.2 Manual external disinfection WARNING Incomplete disinfection. Infection hazard.
Instructions for use SMARTtorque S609 C - 1.008.1644 SMARTtorque Mini S605 C - 1.008.1645 SMARTtorque S608 C - 3.001.6560 7 Processing steps in accordance with ISO 17664 | 7.4 Care products and systems - Servicing WARNING Sharp tool in the medical device.
Instructions for use SMARTtorque S609 C - 1.008.1644 SMARTtorque Mini S605 C - 1.008.1645 SMARTtorque S608 C - 3.001.6560 7 Processing steps in accordance with ISO 17664 | 7.4 Care products and systems - Servicing Note KaVo only guarantees that its products will function properly if the care prod- ucts listed as accessories are used, since these products have been tested for proper use on our products.
Instructions for use SMARTtorque S609 C - 1.008.1644 SMARTtorque Mini S605 C - 1.008.1645 SMARTtorque S608 C - 3.001.6560 7 Processing steps in accordance with ISO 17664 | 7.5 Packaging ▶ Remove the service coupling chuck from the side hatch of the QUATTRO- care PLUS and attach it to coupling service station four, on the far right.
Instructions for use SMARTtorque S609 C - 1.008.1644 SMARTtorque Mini S605 C - 1.008.1645 SMARTtorque S608 C - 3.001.6560 7 Processing steps in accordance with ISO 17664 | 7.7 Storage Sterilization parameters: Select a suitable procedure (depending on the available autoclave) from the fol- lowing sterilization processes: ▪...
Instructions for use SMARTtorque S609 C - 1.008.1644 SMARTtorque Mini S605 C - 1.008.1645 SMARTtorque S608 C - 3.001.6560 8 Optional aids 8 Optional aids Available from dental suppliers. Material summary Mat. No. Spare turbine Standard 1.008.4163 Spare turbine Mini 1.008.4164...
Instructions for use SMARTtorque S609 C - 1.008.1644 SMARTtorque Mini S605 C - 1.008.1645 SMARTtorque S608 C - 3.001.6560 9 Terms and conditions of warranty | 7.7 Storage 9 Terms and conditions of warranty The following Terms and conditions of warranty apply to this KaVo medical de-...
Need help?
Do you have a question about the SMARTtorque S609 C and is the answer not in the manual?
Questions and answers