Heat pump presets and feature ranges cont.
Function
Compressor Lockout Temperature
Only Available for Single Fuel Heat Pump Systems
Dual Fuel Breakpoint*
Switchover temp
Dual Fuel Changeover Timer*
Safety Temps
Eco Temps
*Can be set manually during Pro Setup.
Installation Overview - Standard Presets and Feature Ranges
Notes
Compressor Lockout Default Temp: -25°F
Range: -25°F to 32°F OR Always
Dual Fuel Breakpoint Default Temp: 30°F
Range: 10°F to 50°F, Always or Never
Options: Never, 1 hr, 2 hr, 4 hr (default), 8 hr, 12 hr
Heat Default Temp: 40°F
Heat Range: 35-45
Cool Default Setting: Off
Cool Range: 95-105
Heat Default Temp: 56°F
Heat Range: 40°F to 70°F
Cool Default Temps: 82°F
Cool Range: 76°F to 95°F
47