i550 motec frequency inverter
0.37 ... 45 kW
Operating instructions i550 motec frequency inverter | 1
www.lenze.com

Advertisement

loading
Need help?

Need help?

Do you have a question about the i550 and is the answer not in the manual?

Questions and answers

Summary of Contents for Lenze i550

  • Page 1 Operating instructions i550 motec frequency inverter | 1 Operating instructions i550 motec frequency inverter  Home  General information  Safety instructions  Technical data  Mechanical installation  Electrical installation  Commissioning  Troubleshooting  Disposal 0.37 ... 45 kW www.lenze.com...
  • Page 2 Operating instructions i550 motec frequency inverter | 2 General information Overview Information Identification Conventions  Hardware overview of the inverter Extension box (option) Nameplate  PE connec on Operating element 1 and potentiometer, option  Wall adapter, op on X100.1...
  • Page 3 The complete documentation, further − The cables must be installed in accordance with EN IEC 60204-1 or US National Electrical Code information and tools regarding Lenze products can be found on the Internet: ...
  • Page 4 Operating instructions i550 motec frequency inverter | 4 General information Overview Information Identification Conventions  Identification of the products    Rated power Mains voltage and connection type Integrated functional safety Application area 0.37 kW 3/PE AC 230/240 V...
  • Page 5 Operating instructions i550 motec frequency inverter | 5 General information Overview Information Identification Conventions  Safety instructions Numeric notation By safety instructions, we mean information for the use of products that serves to warn the As a rule, a period is used as a decimal separator in this documentation.
  • Page 6 Operating instructions i550 motec frequency inverter | 6 Safety instructions Basic safety instructions Residual hazards  Basic safety instructions DANGER! WARNING!      Disregarding the following basic safety instructions and safety information may lead to severe Functional safety personal injury and damage to property! Certain variants of the product support safety functions (e.g.
  • Page 7 Operating instructions i550 motec frequency inverter | 7 Safety instructions Basic safety instructions Residual hazards  Residual hazards Product The user must take the residual hazards mentioned into consideration in the risk assessment for Observe the warning signs on the product! ...
  • Page 8 Operating instructions i550 motec frequency inverter | 8 Technical data Standards and operating conditions  Standards and operating conditions CE (European Union)  UKCA (Great Britain) Market approvals UL (USA) Further information and certificates of approval: https://www.lenze.com/en-de/products/inverters/frequency-inverters/i550-motec-frequency-inverter CSA (Canada) ...
  • Page 9 Operating instructions i550 motec frequency inverter | 9 Mechanical installation Design/mounting Wall ... Extension box Design/mounting Motor  Dimensions and assembly – Inverter without extension box NOTICE  The specified installation clearances are minimum dimensions to ensure a sufficient air circulation for cooling purposes.
  • Page 10 Operating instructions i550 motec frequency inverter | 10 Mechanical installation Design/mounting Wall ... Extension box Design/mounting Motor  Dimensions and assembly – Inverter with extension box NOTICE  The specified installation clearances are minimum dimensions to ensure a sufficient air circulation for cooling purposes.
  • Page 11 Operating instructions i550 motec frequency inverter | 11 Mechanical installation Design/mounting Wall ... Extension box Design/mounting Motor  Dimensions and assembly – Inverter without extension box NOTICE  The specified installation clearances are minimum dimensions to ensure a sufficient air circulation for cooling purposes.
  • Page 12 Operating instructions i550 motec frequency inverter | 12 Electrical installation Preparation Connection diagram Motor connection 3-phase | 230/240 V 3-phase | 400 V 3-phase | 480 V Control connections PTC input Networks Functional safety Safe torque off (STO)  NOTICE ...
  • Page 13 Q4/2 connectors. The mains cables are looped through from one inverter to the next via the Han Q4/2 connector. System cables " " Lenze offers ready-made system cables for connecting and interconnecting Lenze products. For more information, refer to the "Accessories for frequency and servo inverters" brochure. " " www.lenze.com...
  • Page 14 Operating instructions i550 motec frequency inverter | 14 Electrical installation Preparation Connection diagram Motor connection 3-phase | 230/240 V 3-phase | 400 V 3-phase | 480 V Control connections PTC input Networks Functional safety Safe torque off (STO)  Motor connection For the motor connection, the inverter is equipped with a Han Q8 connector, an M23/M40 ...
  • Page 15 Operating instructions i550 motec frequency inverter | 15 Electrical installation Preparation Connection diagram Motor connection 3-phase | 230/240 V 3-phase | 400 V 3-phase | 480 V Control connections PTC input Networks Functional safety Safe torque off (STO)  3-phase mains connection 230/240 V (195 V ... 264 V, 45 Hz ... 65 Hz) Connection data for version with cable gland ...
  • Page 16 Operating instructions i550 motec frequency inverter | 16 Electrical installation Preparation Connection diagram Motor connection 3-phase | 230/240 V 3-phase | 400 V 3-phase | 480 V Control connections PTC input Networks Functional safety Safe torque off (STO)  3-phase mains connection 400 V (340 V ... 528 V, 45 Hz ... 65 Hz) Connection data for version with cable gland ...
  • Page 17 Operating instructions i550 motec frequency inverter | 17 Electrical installation Preparation Connection diagram Motor connection 3-phase | 230/240 V 3-phase | 400 V 3-phase | 480 V Control connections PTC input Networks Functional safety Safe torque off (STO)  3-phase mains connection 480 V (340 V ... 528 V, 45 Hz ... 65 Hz) Connection data for version with cable gland ...
  • Page 18 Operating instructions i550 motec frequency inverter | 18 Electrical installation Preparation Connection diagram Motor connection 3-phase | 230/240 V 3-phase | 400 V 3-phase | 480 V Control connections PTC input Networks Functional safety Safe torque off (STO)  Control connections The functional assignment of the X3.x connectors is configurable.
  • Page 19 Operating instructions i550 motec frequency inverter | 19 Electrical installation Preparation Connection diagram Motor connection 3-phase | 230/240 V 3-phase | 400 V 3-phase | 480 V Control connections PTC input Networks Functional safety Safe torque off (STO)  PTC input In the default setting, the motor temperature monitoring is active! ...
  • Page 20 Control connections PTC input Networks Functional safety Safe torque off (STO)  Networks The Ethernet interface of the i550 motec inverter supports the typical topologies and protocols  of the following networks: − EtherCAT  − EtherNet/IP − Modbus TCP ...
  • Page 21 Operating instructions i550 motec frequency inverter | 21 Electrical installation Preparation Connection diagram Motor connection 3-phase | 230/240 V 3-phase | 400 V 3-phase | 480 V Control connections PTC input Networks Functional safety Safe torque off (STO)  Functional safety...
  • Page 22 Operating instructions i550 motec frequency inverter | 22 Electrical installation Preparation Connection diagram Motor connection 3-phase | 230/240 V 3-phase | 400 V 3-phase | 480 V Control connections PTC input Networks Functional safety Safe torque off (STO)  Safe torque off (STO) Connection of active and passive sensors The connection diagrams shown are only example circuits.
  • Page 23 Operating instructions i550 motec frequency inverter | 23 Commissioning Initial switch-on Important notices EASY Starter Quick commissioning Parameter overview Favorites Basic setting Motor control Additional functions  Initial switch-on Carry out functional test Objective: The motor connected to the inverter should rotate within the shortest possible time.
  • Page 24 Operating instructions i550 motec frequency inverter | 24 Commissioning Initial switch-on Important notices EASY Starter Quick commissioning Parameter overview Favorites Basic setting Motor control Additional functions  Important notices DANGER!    Unexpected and dangerous motor movements and system movements Incorrect settings during commissioning may cause unexpected and dangerous motor and ...
  • Page 25 Operating instructions i550 motec frequency inverter | 25 Commissioning Initial switch-on Important notices EASY Starter Quick commissioning Parameter overview Favorites Basic setting Motor control Additional functions  Engineering Tool »EASY Starter« Commissioning and diagnostics are performed via the "EASY Starter" Engineering Tool.
  • Page 26 Operating instructions i550 motec frequency inverter | 26 Commissioning Initial switch-on Important notices EASY Starter Quick commissioning Parameter overview Favorites Basic setting Motor control Additional functions  Quick commissioning 1. Load default setting: 0x2022:001 = "on / start [1]" ...
  • Page 27 Operating instructions i550 motec frequency inverter | 27 Commissioning Initial switch-on Important notices EASY Starter Quick commissioning Parameter overview Favorites Basic setting Motor control Additional functions  The most important parameters at a glance This chapter contains the most important parameters and selections.
  • Page 28 Operating instructions i550 motec frequency inverter | 28 Commissioning Initial switch-on Important notices EASY Starter Quick commissioning Parameter overview Favorites Basic setting Motor control Additional functions  Group 0 - favorites Index Name Possible settings/value ranges Selection no. Information ...
  • Page 29 Operating instructions i550 motec frequency inverter | 29 Commissioning Initial switch-on Important notices EASY Starter Quick commissioning Parameter overview Favorites Basic setting Motor control Additional functions  Group 0 - favorites Index Name Possible settings/value ranges Selection no. Information ...
  • Page 30 Operating instructions i550 motec frequency inverter | 30 Commissioning Initial switch-on Important notices EASY Starter Quick commissioning Parameter overview Favorites Basic setting Motor control Additional functions  Group 0 - favorites Index Name Possible settings/value ranges Selection no. Information ...
  • Page 31 Operating instructions i550 motec frequency inverter | 31 Commissioning Initial switch-on Important notices EASY Starter Quick commissioning Parameter overview Favorites Basic setting Motor control Additional functions  Group 2 - basic setting Index Name Possible settings Selection no. Information ...
  • Page 32 Operating instructions i550 motec frequency inverter | 32 Commissioning Initial switch-on Important notices EASY Starter Quick commissioning Parameter overview Favorites Basic setting Motor control Additional functions  Group 3 - motor control Index Name Possible settings Selection no. Information ...
  • Page 33 Operating instructions i550 motec frequency inverter | 33 Commissioning Initial switch-on Important notices EASY Starter Quick commissioning Parameter overview Favorites Basic setting Motor control Additional functions  Group 7 - additional functions Index Name Possible settings Selection no. Information ...
  • Page 34 Operating instructions i550 motec frequency inverter | 34 Troubleshooting Diagnostics Error codes Status LEDs Support  Diagnostics The inverter provides many diagnostic parameters which are helpful for operation, maintenance,  error diagnosis, error correction, etc. In the "EASY Starter" you have access to the diagnostic parameters of the inverter via the ...
  • Page 35 Operating instructions i550 motec frequency inverter | 35 Troubleshooting Diagnostics Error codes Status LEDs Support  Error codes Error code Description Classification Remedy Blocking time [s]  − Check motor and wiring for short circuits. − Check brake resistor and wiring.
  • Page 36 Operating instructions i550 motec frequency inverter | 36 Troubleshooting Diagnostics Error codes Status LEDs Support  Error codes Error code Description Classification Remedy Blocking time [s]  − Check and correct the assignment of the triggers to the functions. 6280...
  • Page 37 Operating instructions i550 motec frequency inverter | 37 Troubleshooting Diagnostics Error codes Status LEDs Support  Status LEDs You can quickly obtain information on some operating states via the large "DRIVE" LED status  display on the inverter. This status display is composed of a blue LED "RDY" and a red LED "ERR", which emit specific blinking patterns depending on the operating status: ...
  • Page 38 Operating instructions i550 motec frequency inverter | 38 Troubleshooting Diagnostics Error codes Status LEDs Support  Support Further information can be found on the online page  www.lenze.com/product-information   The material number of the product can be found on the nameplate.
  • Page 39 Operating instructions i550 motec frequency inverter | 39 Disposal Disposal  If pollutants are disposed off improperly, they may cause a lasting damage to human health and the environment. Thus, electrical and electronic equipment must be collected separately from ...