Page 1
Operating instructions i550 motec frequency inverter | 1 Operating instructions i550 motec frequency inverter Home General information Safety instructions Technical data Mechanical installation Electrical installation Commissioning Troubleshooting Disposal 0.37 ... 45 kW www.lenze.com...
Page 2
Operating instructions i550 motec frequency inverter | 2 General information Overview Information Identification Conventions Hardware overview of the inverter Extension box (option) Nameplate PE connec on Operating element 1 and potentiometer, option Wall adapter, op on X100.1...
Page 3
The complete documentation, further − The cables must be installed in accordance with EN IEC 60204-1 or US National Electrical Code information and tools regarding Lenze products can be found on the Internet: ...
Page 4
Operating instructions i550 motec frequency inverter | 4 General information Overview Information Identification Conventions Identification of the products Rated power Mains voltage and connection type Integrated functional safety Application area 0.37 kW 3/PE AC 230/240 V...
Page 5
Operating instructions i550 motec frequency inverter | 5 General information Overview Information Identification Conventions Safety instructions Numeric notation By safety instructions, we mean information for the use of products that serves to warn the As a rule, a period is used as a decimal separator in this documentation.
Page 6
Operating instructions i550 motec frequency inverter | 6 Safety instructions Basic safety instructions Residual hazards Basic safety instructions DANGER! WARNING! Disregarding the following basic safety instructions and safety information may lead to severe Functional safety personal injury and damage to property! Certain variants of the product support safety functions (e.g.
Page 7
Operating instructions i550 motec frequency inverter | 7 Safety instructions Basic safety instructions Residual hazards Residual hazards Product The user must take the residual hazards mentioned into consideration in the risk assessment for Observe the warning signs on the product! ...
Page 8
Operating instructions i550 motec frequency inverter | 8 Technical data Standards and operating conditions Standards and operating conditions CE (European Union) UKCA (Great Britain) Market approvals UL (USA) Further information and certificates of approval: https://www.lenze.com/en-de/products/inverters/frequency-inverters/i550-motec-frequency-inverter CSA (Canada) ...
Page 9
Operating instructions i550 motec frequency inverter | 9 Mechanical installation Design/mounting Wall ... Extension box Design/mounting Motor Dimensions and assembly – Inverter without extension box NOTICE The specified installation clearances are minimum dimensions to ensure a sufficient air circulation for cooling purposes.
Page 10
Operating instructions i550 motec frequency inverter | 10 Mechanical installation Design/mounting Wall ... Extension box Design/mounting Motor Dimensions and assembly – Inverter with extension box NOTICE The specified installation clearances are minimum dimensions to ensure a sufficient air circulation for cooling purposes.
Page 11
Operating instructions i550 motec frequency inverter | 11 Mechanical installation Design/mounting Wall ... Extension box Design/mounting Motor Dimensions and assembly – Inverter without extension box NOTICE The specified installation clearances are minimum dimensions to ensure a sufficient air circulation for cooling purposes.
Page 12
Operating instructions i550 motec frequency inverter | 12 Electrical installation Preparation Connection diagram Motor connection 3-phase | 230/240 V 3-phase | 400 V 3-phase | 480 V Control connections PTC input Networks Functional safety Safe torque off (STO) NOTICE ...
Page 13
Q4/2 connectors. The mains cables are looped through from one inverter to the next via the Han Q4/2 connector. System cables " " Lenze offers ready-made system cables for connecting and interconnecting Lenze products. For more information, refer to the "Accessories for frequency and servo inverters" brochure. " " www.lenze.com...
Page 14
Operating instructions i550 motec frequency inverter | 14 Electrical installation Preparation Connection diagram Motor connection 3-phase | 230/240 V 3-phase | 400 V 3-phase | 480 V Control connections PTC input Networks Functional safety Safe torque off (STO) Motor connection For the motor connection, the inverter is equipped with a Han Q8 connector, an M23/M40 ...
Page 15
Operating instructions i550 motec frequency inverter | 15 Electrical installation Preparation Connection diagram Motor connection 3-phase | 230/240 V 3-phase | 400 V 3-phase | 480 V Control connections PTC input Networks Functional safety Safe torque off (STO) 3-phase mains connection 230/240 V (195 V ... 264 V, 45 Hz ... 65 Hz) Connection data for version with cable gland ...
Page 16
Operating instructions i550 motec frequency inverter | 16 Electrical installation Preparation Connection diagram Motor connection 3-phase | 230/240 V 3-phase | 400 V 3-phase | 480 V Control connections PTC input Networks Functional safety Safe torque off (STO) 3-phase mains connection 400 V (340 V ... 528 V, 45 Hz ... 65 Hz) Connection data for version with cable gland ...
Page 17
Operating instructions i550 motec frequency inverter | 17 Electrical installation Preparation Connection diagram Motor connection 3-phase | 230/240 V 3-phase | 400 V 3-phase | 480 V Control connections PTC input Networks Functional safety Safe torque off (STO) 3-phase mains connection 480 V (340 V ... 528 V, 45 Hz ... 65 Hz) Connection data for version with cable gland ...
Page 18
Operating instructions i550 motec frequency inverter | 18 Electrical installation Preparation Connection diagram Motor connection 3-phase | 230/240 V 3-phase | 400 V 3-phase | 480 V Control connections PTC input Networks Functional safety Safe torque off (STO) Control connections The functional assignment of the X3.x connectors is configurable.
Page 19
Operating instructions i550 motec frequency inverter | 19 Electrical installation Preparation Connection diagram Motor connection 3-phase | 230/240 V 3-phase | 400 V 3-phase | 480 V Control connections PTC input Networks Functional safety Safe torque off (STO) PTC input In the default setting, the motor temperature monitoring is active! ...
Page 20
Control connections PTC input Networks Functional safety Safe torque off (STO) Networks The Ethernet interface of the i550 motec inverter supports the typical topologies and protocols of the following networks: − EtherCAT − EtherNet/IP − Modbus TCP ...
Page 21
Operating instructions i550 motec frequency inverter | 21 Electrical installation Preparation Connection diagram Motor connection 3-phase | 230/240 V 3-phase | 400 V 3-phase | 480 V Control connections PTC input Networks Functional safety Safe torque off (STO) Functional safety...
Page 22
Operating instructions i550 motec frequency inverter | 22 Electrical installation Preparation Connection diagram Motor connection 3-phase | 230/240 V 3-phase | 400 V 3-phase | 480 V Control connections PTC input Networks Functional safety Safe torque off (STO) Safe torque off (STO) Connection of active and passive sensors The connection diagrams shown are only example circuits.
Page 23
Operating instructions i550 motec frequency inverter | 23 Commissioning Initial switch-on Important notices EASY Starter Quick commissioning Parameter overview Favorites Basic setting Motor control Additional functions Initial switch-on Carry out functional test Objective: The motor connected to the inverter should rotate within the shortest possible time.
Page 24
Operating instructions i550 motec frequency inverter | 24 Commissioning Initial switch-on Important notices EASY Starter Quick commissioning Parameter overview Favorites Basic setting Motor control Additional functions Important notices DANGER! Unexpected and dangerous motor movements and system movements Incorrect settings during commissioning may cause unexpected and dangerous motor and ...
Page 25
Operating instructions i550 motec frequency inverter | 25 Commissioning Initial switch-on Important notices EASY Starter Quick commissioning Parameter overview Favorites Basic setting Motor control Additional functions Engineering Tool »EASY Starter« Commissioning and diagnostics are performed via the "EASY Starter" Engineering Tool.
Page 27
Operating instructions i550 motec frequency inverter | 27 Commissioning Initial switch-on Important notices EASY Starter Quick commissioning Parameter overview Favorites Basic setting Motor control Additional functions The most important parameters at a glance This chapter contains the most important parameters and selections.
Page 28
Operating instructions i550 motec frequency inverter | 28 Commissioning Initial switch-on Important notices EASY Starter Quick commissioning Parameter overview Favorites Basic setting Motor control Additional functions Group 0 - favorites Index Name Possible settings/value ranges Selection no. Information ...
Page 29
Operating instructions i550 motec frequency inverter | 29 Commissioning Initial switch-on Important notices EASY Starter Quick commissioning Parameter overview Favorites Basic setting Motor control Additional functions Group 0 - favorites Index Name Possible settings/value ranges Selection no. Information ...
Page 30
Operating instructions i550 motec frequency inverter | 30 Commissioning Initial switch-on Important notices EASY Starter Quick commissioning Parameter overview Favorites Basic setting Motor control Additional functions Group 0 - favorites Index Name Possible settings/value ranges Selection no. Information ...
Page 31
Operating instructions i550 motec frequency inverter | 31 Commissioning Initial switch-on Important notices EASY Starter Quick commissioning Parameter overview Favorites Basic setting Motor control Additional functions Group 2 - basic setting Index Name Possible settings Selection no. Information ...
Page 32
Operating instructions i550 motec frequency inverter | 32 Commissioning Initial switch-on Important notices EASY Starter Quick commissioning Parameter overview Favorites Basic setting Motor control Additional functions Group 3 - motor control Index Name Possible settings Selection no. Information ...
Page 33
Operating instructions i550 motec frequency inverter | 33 Commissioning Initial switch-on Important notices EASY Starter Quick commissioning Parameter overview Favorites Basic setting Motor control Additional functions Group 7 - additional functions Index Name Possible settings Selection no. Information ...
Page 34
Operating instructions i550 motec frequency inverter | 34 Troubleshooting Diagnostics Error codes Status LEDs Support Diagnostics The inverter provides many diagnostic parameters which are helpful for operation, maintenance, error diagnosis, error correction, etc. In the "EASY Starter" you have access to the diagnostic parameters of the inverter via the ...
Page 35
Operating instructions i550 motec frequency inverter | 35 Troubleshooting Diagnostics Error codes Status LEDs Support Error codes Error code Description Classification Remedy Blocking time [s] − Check motor and wiring for short circuits. − Check brake resistor and wiring.
Page 36
Operating instructions i550 motec frequency inverter | 36 Troubleshooting Diagnostics Error codes Status LEDs Support Error codes Error code Description Classification Remedy Blocking time [s] − Check and correct the assignment of the triggers to the functions. 6280...
Page 37
Operating instructions i550 motec frequency inverter | 37 Troubleshooting Diagnostics Error codes Status LEDs Support Status LEDs You can quickly obtain information on some operating states via the large "DRIVE" LED status display on the inverter. This status display is composed of a blue LED "RDY" and a red LED "ERR", which emit specific blinking patterns depending on the operating status: ...
Page 38
Operating instructions i550 motec frequency inverter | 38 Troubleshooting Diagnostics Error codes Status LEDs Support Support Further information can be found on the online page www.lenze.com/product-information The material number of the product can be found on the nameplate.
Page 39
Operating instructions i550 motec frequency inverter | 39 Disposal Disposal If pollutants are disposed off improperly, they may cause a lasting damage to human health and the environment. Thus, electrical and electronic equipment must be collected separately from ...