Download Print this page

Advertisement

Quick Links

Installation and Operation Manual
Ortal 60 Series
Ortal 60 Series Fireplaces:
60 Front Facing
60H Front Facing
60 Corner (RS/LS)
60H Corner (RS/LS)
60 Three Sided (TS)
60H Three Sided (TS)
Ortal Installation Manual: 60 Series (V1.0)

Advertisement

loading
Need help?

Need help?

Do you have a question about the 60 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ORTAL 60 Series

  • Page 1 Installation and Operation Manual Ortal 60 Series Ortal 60 Series Fireplaces: 60 Front Facing 60H Front Facing 60 Corner (RS/LS) 60H Corner (RS/LS) 60 Three Sided (TS) 60H Three Sided (TS) Ortal Installation Manual: 60 Series (V1.0)
  • Page 2 WARNING: MATERIAL USAGE All materials and objects used to carry out the installation must be certified/approved or specified by Ortal and are suitable for use. Do NOT install the system with different materials or objects than those approved for installation by Ortal.
  • Page 3 Table of Contents General 2  Safety Information and Warnings   Product Information   Models   Certification   Rating Label   Zero-Clearance Stand-Offs   Installation 8  Prior to Installation   Locate the Fireplace   Fireplace Installation   First Trip to Site: Planning  ...
  • Page 4 Electrical 41  Electrical Requirements     Pairing the Remote and Receiver Wiring Diagrams   Home Automation Wiring Diagram   Interior Design Media 46  Media Placement Guidelines   Glass Media Placement   Stone Media Placement   Log Media Placement   Operation 49 ...
  • Page 5 For more information on Power Venting, please refer to the Power Vent System Installation and Operation Manual. Venting is not supplied by Ortal with the fireplace. The fireplace is certified to be used with, and can be obtained from, the ...
  • Page 6 You must instruct the owner before handing over the fireplace where this label can be found. OWNERS: Make sure the installer leaves your fireplace’s rating label in an area that is easily accessible for you. This information is required for servicing and receiving replacement parts. 60 Series Rating Label...
  • Page 7 Protective Cover: Attached under the bottom front part of the fireplace to protect the double glass fans during shipping and installation. This cover is present on double glass models only. Screen models do not come with a protective cover. 60 Series Front Facing Zero-Clearance Stand-Offs (Isometric View)
  • Page 8 Installation Prior to Installation Locate the Fireplace Keep the following factors in mind when selecting a location for the fireplace: Fireplace clearance requirements (review “General Clearances” section on page 15).  Heat release and air intake requirements (review “Heat Release” section on page 16, and “Air Intake Opening” section on ...
  • Page 9 In addition, the installer must review and explain the following to the owner: Safety warnings  Fireplace operation  Warranty requirements  Maintenance requirements   Glass is hot during and after operation. If any questions or concerns arise, owner must contact the local Ortal dealer/installer for support. ...
  • Page 10 Building Around the Fireplace Building Checklist The following building checklist is a quick reference for a typical 60 series fireplace installation. This list is not exhaustive and does not supplement thorough review of the installation manual.  Fireplace Location: Ensure the location allows for min. 40” clearance from viewing area to furniture and other combustibles.
  • Page 11 Framing Framing Requirements Fireplace chase may be framed with either combustible (typically wood studs) or non-combustible framing (typically metal studs). Any framing within 10 ” from the top of the fireplace glass (viewing area) must be non-combustible. Any framing after that point may be combustible.
  • Page 12 Framing Dimensions The following framing information applies to combustible and non-combustible framing material. The diagrams presented are for illustrative purposes only. There are multiple approved framing scenarios. A flush application is not the only permitted application. The fireplace may be recessed into the wall. Refer to diagrams and values below and in the following pages for details. 60 Front (F) Series Fireplace Glass...
  • Page 13 60 Corner (RS/LS) Series Fireplace Glass Glass Height Length Depth Stand-Off Legs Length Height 60 RS/LS " ” ” ” ” ” " 60H RS/LS ” ” ” ” ” ” ” Framing Fireplace 60 RS/LS 60H RS/LS A: Height "...
  • Page 14 60 Three Sided (TS) Series Fireplace Glass Glass Height Length Depth Stand-Off Legs Length Height 60 TS " ” ” ” ” ” " 60H TS ” ” ” ” ” ” ” Framing Fireplace 60 TS 60H TS A: Height "...
  • Page 15 General Clearances Viewing Area Clearance Zone The viewing area clearance zone is an area that extends perpendicular from the fireplace viewing area. The depth of the viewing area clearance zone depends on the combustibility of the material in question. Distance is measured from the fireplace heat barrier. Non-Combustible Materials Must be minimum 12 inches from fireplace viewing area.
  • Page 16 This heat is generated convectively as the fireplace heats up. It is separate from exhaust heat produced in the combustion chamber of the fireplace. For safety purposes, a heat release is required in order to keep the wall around the fireplace cool. Heat release requirements are the same for all 60 series models. Heat Release Requirements The heat release must be located at or near the top of the fireplace chase and start within 6 inches (0-6 inches max) of the ...
  • Page 17 Vertical Heat Release: Split Front Vertical Heat Release: Full Side The heat release is oriented vertically and split between the two sides The heat release is oriented vertically. Entire heat release of the chase. is on one side of the fireplace chase. Split Front Vertical Heat Release Full Vertical Heat Release on One Side Sprinkler Clearance to Heat Release...
  • Page 18 Air Intake Opening For fireplaces with a double glass heat barrier only, an air intake opening must be incorporated into the framing and finish around the fireplace. The air intake opening is essential to maintain cool air flow between the double glass panels by allowing the double glass fans to circulate room air through the glass panels and up into the chase.
  • Page 19 Air Intake for a Platform NOTE: Please refer to the “Chase Floor/Platform” section on page 11 for details on platform construction.
  • Page 20 The decision to install a television above an Ortal fireplace is up to the discretion of the owner. TV and art manufacturers may specify that their product should not be installed on, near or above a heat source. Ortal will not be held liable for any adverse effects on a TV, artwork or other equipment located near the Ortal fireplace.
  • Page 21 Recessed TV/Artwork When the TV is mounted on a wall that recesses over fireplace, the TV must be at least 12 inches from the top of the fireplace glass viewing area. At 12 inches above the fireplace viewing area, maximum possible recess is 5 inches. A deeper recess will interfere with required clearances to venting.
  • Page 22 Access Panel An access panel is not required (see note below for exception), but it is highly recommended. It allows for access to the fireplace’s gas and electrical components for servicing. NOTE: An access panel at the fireplace is required for fireplaces with a power vent to allow access to the power vent control box for servicing.
  • Page 23 Recessed Ledge Detail A ledge over the top of a fireplace that is less than 24 inches from the top of the fireplace viewing area must maintain a minimum of 12 inches from the top of the viewing area to the top of the framing. Entire structure must be non-combustible (framing and finish).
  • Page 24 The following drawing shows a recommended approach to this type of installation. Please note that these drawings are not to scale. All fireplace drawings with correct dimensions are available on the Ortal website.
  • Page 25 Step-by-Step Chase Construction The following checklist is a simplified overview of typical chase construction for a 60 series fireplace installation. This list is not exhaustive and does not supplement thorough review of the installation manual. Step 1 BUILD BACK AND SIDE WALLS Frame the back and side walls according to framing requirements.
  • Page 26 Finishing The following diagrams show various finish applications. Diagrams apply to both combustible and non-combustible finish material. IMPORTANT NOTES: All recessed installations must comply with applicable maximum overhang limit and side wall clearances. See “Maximum  Overhang Depth” and “Clearance to a Side Wall” sections on page 15 for details. No material is permitted to extend past the metal lip surrounding the fireplace viewing area.
  • Page 27 Recessed Installation Diagram applies to both combustible and non-combustible finish material. The finish must maintain at least a ” clearance to the fireplace to both the top and bottom recesses. Maximum Overhang Depth Overhang depth of a recessed fireplace must not exceed 12 inches. Overhang depth is measured from the edge of the fireplace lip to the out-most part of the wall (including finish material).
  • Page 28 Review “Vent Configurations” section on page 29 to determine if your fireplace needs a power vent. ORTAL POWER VENT NOTE: See the Ortal Power Vent Manual for more details on power venting. ENERVEX POWER VENT NOTE: See Ortal’s Enervex RS Power Vent Manual for more details on power venting with an Enervex power vent.
  • Page 29 The following sections provide information for calculating vent configuration distances and elbows. For vent configurations that cannot conform to these guidelines, consider Ortal’s Power Vent System, or contact Ortal for assistance. Power Vent information can be found in the Power Vent Installation Manual.
  • Page 30 TERMINATION CAP NOTE: Low Profile Termination Cap and Sconce Termination Cap can negatively impact flame appearance and are not recommended for use with the fireplace. Allowable Maximum Horizontal Runs 60 Series (135 Single Burner) V minimum = 3 feet Vertical (V)
  • Page 31 Vent Restrictor Sizing Guidelines The restrictor sizing tables in this section determine the recommended restrictor for your vent configuration. These tables show Ortal’s recommendations only. The Environment, gas type and other factors may affect the best restrictor choice. How to use the “Recommended Restrictor” tables: Find the total vertical rise in your vent configuration along the y-axis.
  • Page 32 Vent Termination Horizontal Termination Clearance Diagram Location Country Minimum Clearance Description Clearance above grade, veranda, porch, deck, or balcony. US & 12 inches NOTE: On private property where termination is less than 7 feet above a sidewalk, driveway, Canada deck, porch, veranda, or balcony, use of a listed cap shield is suggested. ...
  • Page 33 Covered Alcove: spaces open only on one side and with an overhang Horizontal Termination Clearances Continued: Covered Alcove Application Location Country Minimum Clearance Description Clearance under non-vinyl veranda, porch, deck, balcony, or overhang. NOTE: Termination in a covered alcove space is permitted with the dimensions specified. 1.
  • Page 34 Vertical Termination Clearance Diagram NOTE: This chart does not apply to a chimney shroud application. See the “Chimney Shroud” section on the next page for more information. TERMINATION CAP NOTE: A Low Profile Termination Cap can negatively impact flame appearance and is not recommended for use with the fireplace.
  • Page 35 Chimney Shroud Top Open Keep a minimum 6-inch clearance around the diameter of the cap’s side edge and extending above and below the cap. Sides Open Keep a minimum 6-inch clearance around the diameter of the cap’s side edge, and a minimum 10-inch clearance above the top of the cap.
  • Page 36  This appliance must be properly connected to a venting system in accordance with the Ortal’s installation instructions. Operation of this appliance when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possibly death.
  • Page 37 Vent Configuration Minimum Vertical Rise: 10 feet (see diagram below)  Maximum Vertical Rise: 40 feet (see diagram below)  Offsets: Two 45˚ offsets may be used directly on the fireplace with up to a 6-foot section between them. The minimum ...
  • Page 38 Check with your authority having jurisdiction for more information. WARNING: The main gas valve must be installed to allow complete disconnection of the fireplace from the gas supply piping system for servicing purposes. Screen Models 60 Series Fireplaces with Screen: Left, Right, Back, Front...
  • Page 39 Gas conversion (NG to LP or LP to NG) can be done in the field. Gas conversion must only be performed by a technician who has specific authorization by Ortal to change these components. The conversion kit must be supplied by Ortal. Using parts from other manufacturers or having an unauthorized party perform the conversion will void your fireplace’s warranty.
  • Page 40 Pilot Base Connection fitting 4mm One-piece Thermocouple NG Fitting for main line inlet to gas valve GV60 Thermocouple LPG The manufacturer of Ortal’s gas and electrical components is Mertik Maxitrol. For information on these components, please visit the manufacturer’s website: www.mertikmaxitrol.com ...
  • Page 41 Electrical WARNING: Disconnect the power supply before servicing any electrical components. Electrical Requirements A duplex receptacle with two outlets (not included) must be installed in the location where the gas and electrical components will be placed, which must be to the side or back of the fireplace within 36 inches of the pilot (see diagram in “Routing the Gas Line” section on page 38).
  • Page 42 Wiring Diagrams The following diagrams show the electrical wiring required for different feature combinations. For wiring diagrams with Ortal or Enervex power vent, refer to the applicable power vent manual. For wiring diagrams with CO shutoff kit, refer to CO Shutoff Kit spec sheet at www.ortalheat.com.
  • Page 43 Wiring Diagram: Screen Fireplace with Interior Lighting...
  • Page 44 Wiring Diagram: Double Glass Fireplace...
  • Page 45 Wiring Diagram: Double Glass Fireplace with Interior Lighting...
  • Page 46 Interior Design Media Ortal offers interior media options such as stones, glass, logs, and embers that can be provided with the fireplace. This section provides guidelines for safe placement of media. It is crucial that the placement guidelines outlined below are followed as a large portion of flame quality issues are caused by improper media setup.
  • Page 47 Media Placement Guidelines When installing media, adhere to the following general guidelines:  Keep the media back from the pilot hood so at least one burner port is open. Crowding around the pilot hood may hinder lighting and could result in potential damage to the fireplace and surrounding area or personal injury. Do not use the hood to support media.
  • Page 48 Log Media Placement Place the logs carefully to block as few ports as possible. If a log is placed over a port, block the port with a “coin” to keep  the flame from creating soot on the media or to manipulate the look of the flame. COINS Block as few ports as possible, and no more than 30% of total ports.
  • Page 49 Operation WARNING – Read these instructions carefully before lighting the fireplace. Four operation options are available for use with the fireplace: 10-Button Remote Control Handset (default option, always included with the fireplace)  Puck Handset (optional accessory)  Wall Switch (optional accessory) ...
  • Page 50 Turning the Fireplace On 1. Press the button until you hear continuous beeping, and a blinking series of lines confirms the start sequence has begun; release buttons. 2. Main gas flows once pilot ignition is confirmed. 3. The system automatically goes into Manual Mode after main burner ignition. NOTE: When pilot ignition is confirmed, motor turns automatically to maximum flame height.
  • Page 51 Operating Instructions Instructions for operating the Puck Handset are shown below. Turning the Fireplace On/Off Firmly press and hold the button until two short beeps confirms the start  sequence has begun; release button. OFF: Firmly press the button.  Increase/Decrease Flame Height INCREASE: To increase flame height, press and hold...
  • Page 52 Wall Switch Control Option Radio Frequency Power Supply Wall Switch IMPORTANT: For safety/communication purposes, the 10-button handset must be located within 26 feet of the receiver. Operating Instructions Turning the Fireplace On/Off ON: Press and hold the ON-OFF button until two short beeps confirms the start sequence has begun;...
  • Page 53 To download the MyFire app, search “MyFire” at the Apple App Store or Google Play. Operating Instructions For setup and operating instructions of the MyFire app, see the Homeowner’s Fireplace Operation Manual, or visit the Ortal website or www.myfireapp.com. MyFire Wi-Fi Box The MyFire Wi-Fi router box provides the Wi-Fi connection that allows the MyFire App to operate the fireplace.
  • Page 54 Submerged Parts Do not use the fireplace if any part has been under water, or if you suspect that it may have been under water. The Ortal dealer service technician must inspect and, if necessary, replace any parts of the control system and any gas controls which have been under water.
  • Page 55 © Ortal 2022 Version 1.0, May 2022 SKU: KPMAN60NLUSV1.0 Ortal USA 8421 Canoga Ave Canoga Park, CA 91304 T: (818) 238-7000 | F: (818) 678-0541 info@ortalheat.com | www.ortalheat.com  ...