Summary of Contents for Moxa Technologies NPort S9650I Series
Page 1
NPort S9000 Series Quick Installation Guide Version 3.1, January 2021 Technical Support Contact Information www.moxa.com/support 2021 Moxa Inc. All rights reserved. P/N: 1802096500012 *1802096500012*...
Page 2
Overview The NPort S9000 Series combines a substation-grade 4/8/16-port RS-232/422/485 serial ports device server with a full-function managed Ethernet switch by integrating a combination of fiber and copper Ethernet ports, allowing you to easily install, manage, and maintain the products and serial devices.
Page 3
Steady On: 10 Mbp Ethernet connection. TX1-TX4 Green The serial port is transmitting data. RX1-RX4 Amber The serial port is receiving data. NPort S9650I Series E1-E4 Green Steady On: When the Ethernet port is transmitting/receiving data S1-S16 Green Steady On: When the serial port is...
Page 4
DIN-Rail Mounting The aluminum DIN-rail attachment plate should already be fixed to the back panel of the NPort S9450I when you take it out of the box. If you need to reattach the DIN-rail attachment plate to the NPort S9450I, make sure the stiff metal spring is situated towards the top as shown in the figures below.
Page 5
Wall-Mounting (optional) For added convenience, the NPort S9450I can be wall-mounted as illustrated below. STEP 1: Remove the aluminum DIN-rail attachment plate from the NPort S9450I’s rear panel, and then attach the wall-mount plates with six M3 screws, as shown on the right.
Page 6
Rack-Mounting Use four screws to attach the NPort S9650I Series to a standard rack. Software Installation Information For the NPort’s configuration, the default IP address of the NPort is 192.168.127.254. You may log in with the account name admin and password moxa to change any settings to meet your network topology (e.g., IP address) or serial device (e.g., serial parameters).
Page 7
Wiring the Redundant Power Inputs for the NPort S9450I Series The NPort S9450I unit has two sets of power inputs: power input 1 and power input 2. Take the following steps to wire the redundant power inputs: 1. Insert the negative/positive DC wires into the N- and L+ terminals.
Page 8
ATTENTION When wiring the relay contact (R), digital input (DI) and power inputs (P1/P2), we suggest using the cable type - AWG (American Wire Gauge) 18-24(1.31-0.205 mm²) and the corresponding pin type cable terminals. The rated temperature of wiring should be at least 105°C.
Page 9
CLASS 1 LED PRODUCT Connecting the Power for the NPort S9650I Series The NPort S9650I Series has two sets of power inputs: power input 1 and power input 2. STEP 1: Insert the dual set positive/negative DC wires into PWR1 and PWR2 terminals (+ →...
Page 10
Indoor use and Pollution degree 2 (The equipment must be dried with a dry cloth.) Overvoltage NPort S9450I Series: Category 2 NPort S9650I Series: Not connected to mains directly Hazardous Location NPort S9450I Series: Temperature code (T-Code)—T4 UL/cUL Class I, Division 2, Groups A, B,...
Page 11
ATTENTION This equipment is intended to be used in a Restricted Access Location. If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. The product ambient temperature should not exceed 85°C. Cet équipement est destiné...