Download Print this page
Moxa Technologies NPort S8000 Series Quick Installation Manual
Moxa Technologies NPort S8000 Series Quick Installation Manual

Moxa Technologies NPort S8000 Series Quick Installation Manual

Hide thumbs Also See for NPort S8000 Series:

Advertisement

Quick Links

Quick Installation Guide
Moxa Americas:
Toll-free: 1-888-669-2872
Tel:
1-714-528-6777
Fax:
1-714-528-6778
Moxa Europe:
Tel:
+49-89-3 70 03 99-0
Fax:
+49-89-3 70 03 99-99
Moxa India:
Tel:
+91-80-4172-9088
Fax:
+91-80-4132-1045
NPort S8000 Series
Edition 6.1, November 2018
Technical Support Contact Information
www.moxa.com/support
 2018 Moxa Inc. All rights reserved.
Moxa China (Shanghai office):
Toll-free: 800-820-5036
Tel:
+86-21-5258-9955
Fax:
+86-21-5258-5505
Moxa Asia-Pacific:
Tel:
+886-2-8919-1230
Fax:
+886-2-8919-1231
P/N: 1802080000015
*1802080000015*

Advertisement

loading

Summary of Contents for Moxa Technologies NPort S8000 Series

  • Page 1 NPort S8000 Series Quick Installation Guide Edition 6.1, November 2018 Technical Support Contact Information www.moxa.com/support Moxa Americas: Moxa China (Shanghai office): Toll-free: 1-888-669-2872 Toll-free: 800-820-5036 Tel: 1-714-528-6777 Tel: +86-21-5258-9955 Fax: 1-714-528-6778 Fax: +86-21-5258-5505 Moxa Europe: Moxa Asia-Pacific: Tel: +49-89-3 70 03 99-0...
  • Page 2: Package Checklist

    Overview The Moxa NPort S8000 series fully integrates an industrial serial device server and redundant managed Ethernet switch into a single device, making it easy to enable your serial devices to operate over a network and connect Ethernet-enabled devices in industrial field applications.
  • Page 3: Hardware Installation Procedure

    LED Indicators—The NPort S8000’s front panel contains some LED indicators as described in the following table. Type Color Meaning PW 1 Green Power 1 input PW 2 Green Power 2 input Ready Steady On: Power is on, and the NPort is booting up.
  • Page 4 Wall Mounting (optional) In high-vibration environments, we suggest using the NPort S8000’s wall-mount kit to fix. The installation procedure is described below: STEP 1: Remove the aluminum DIN-rail attachment plate from the NPort S8000’s rear panel and then attach the wall-mount plates with M3 screws.
  • Page 5: Turbo Ring Dip Switch Settings

    Turbo Ring DIP Switch Settings The default setting for each DIP switch is OFF. The following table explains the effect of setting the DIP switch to the ON position. Turbo Ring Settings DIP 1 DIP 2 DIP 3 DIP 4 –...
  • Page 6 Wiring the Relay Contact The NPort S8000 has two sets of relay outputs: relay 1 and relay 2. Each relay contact consists of two contacts of the terminal block on the NPort S8000’s top panel. Refer to the next section for detailed instructions on how to connect the wires to the terminal block connector and how to attach the terminal block connector to the terminal block receptor.