Configuration for DEC UNIX Environment
Table 12 DIP Switch
Settings
Digital UNIX
Version 4.0 and
5
Later
Configuration 1
If you are using the original Novell NWTAPE driver or any version
created before 11/3/99, you must change the Operating System
Configuration DIP switches so that switches 5 and 8 are OFF. This is
different from their default settings (switches 5 through 8 ON).
Configuration 2
If you use the latest Novell NWTAPE driver (available on the Novell web
site), the Operating System Configuration DIP switches can be left in their
default positions (switches 5 through 8 ON).
Before using the DAT 72 or DDS-4 autoloader in a DEC UNIX
environment, set the operating-system DIP switches as shown below:
S5
OFF
Setting
With Version 4.0 of the Digital UNIX operating system, DEC introduced a
new method of configuring the CAM SCSI driver. Modify the file
as follows:
ddr.dbase
1 Look through the file and locate the database entry for the DEC
TLZ07 DAT drive
2 Copy this entry and paste it later in the file, taking care to maintain
the file syntax.
DAT 72/DDS-4 6-Slot Autoloader User's Guide
Chapter 5 Configuration for Novell and UNIX
Configuration for DEC UNIX Environment
S6
S7
ON
ON
S8
S10
On
ON
/etc./
49
5
5
5