MC300 Prism Management Card User’s Guide, 6311631-10, Ver. 10, Rel. 0, June 2003, Made in USA. Quantum Corporation provides this publication “as is” without warranty of any kind, either express or implied, including but not limited to the implied warranties of merchantability or fitness for a particular purpose.
Using the Prism Management Console Interface ... 4 Home Page ... 5 First Time User Account Setup ... 6 Accessing Online Help... 6 Accessing the Quantum Web Site ... 7 Chapter 2 PMC Server Management Network Configuration Page... 10 Accessing or Editing Network Configuration ... 10 Date and Time Configuration Page ...
Page 11
This document is intended for use by customers who have Audience purchased a Quantum ATL M-Series library and a PMC. Hereafter, the libraries are referred to as ATL M1500 and ATL M2500. This document assumes that the reader has a moderate level of general computer knowledge and server systems administration experience.
Page 12
The Prism Management Console screens that display on your system may vary from those shown in this document. MC300 Prism Management Card User’s Guide Management, explains how to use the Web pages: User Management...
Page 13
Note: Notational This document uses the following conventions: Conventions Note: Caution: MC300 Prism Management Card User’s Guide ® ® Internet Explorer (IE) 5.5 or 6.0 The PMC cannot be accessed with multiple Web browser sessions. When performing a function, do not open a second PMC Web browser instance.
Page 14
Refer to the appropriate product manuals for information about your tape drive and cartridges. Use Adobe or higher to view the appropriate Portable Document Format (PDF) file. MC300 Prism Management Card User’s Guide Document Title 6423001 ATL M-Series Installation Guide...
Page 15
To order documentation on the PMC or other products contact: Quantum P.O. Box 57100 Irvine, CA 92619-7100 (949) 856-7800 (800) 284-5101 Technical Publications To comment on existing documentation send e-mail to: doc-comments@quantum.com Quantum Home Page http://www.Quantum.com MC300 Prism Management Card User’s Guide Preface...
Page 16
Preface Customer Support The Quantum Customer Support Department provides a 24-hour help desk that can be reached at: North/South America: Asia/Pacific Rim: Europe/Middle East/Africa: Send faxes for the Customer Support Department to: North/South America: Asia/Pacific Rim: Europe/Middle East/Africa: Send e-mail for the Customer Support Department to:...
The MC300 Prism Management Card (PMC) is an intelligent server card that plugs directly into the ATL M-Series libraries and is the enabling element for a variety of Prism options. The PMC consists of a single-board server powered by high-performance, industry- standard technology.
Page 18
Note: If you still have problems accessing the IP address, contact your local system administrator for information on including the PMC in your network. MC300 Prism Management Card User’s Guide DHCP Manager Main 192.168.1.1 If the IP address If 192.168.x.x is already used in the network, the PMC assigns itself the static IP address 10.0.0.x instead.
When the correct IP address for the PMC has been entered, the Internet browser displays the Prism Management Console Home MC300 Prism Management Card User’s Guide Accessing the Prism Management Console Web Pages Internet browser software is not supplied with the Note: PMC.
Using the Prism Management Console Interface The Prism Management Console interface (see into three distinct sections: • The Banner frame displays the Quantum logo and software name. Clicking the Quantum logo links you to the Quantum web site. • The Navigation frame lists the Prism Management Console web pages.
The PMC communicates with the library at the library’s default baud rate of 38400. To check or set the library baud rate, use the GUI on the library front panel. MC300 Prism Management Card User’s Guide Chapter 1 Prism Management Console Using the Prism Management Console Interface button.
• Click the A new Internet browser window opens and displays online help for the current Web page. Note: MC300 Prism Management Card User’s Guide A default user name ( admin assigned when you install the PMC. To protect the integrity of your network and PMC...
To access the Quantum Web site: Accessing the Quantum Web Click the Quantum link in the navigation frame of the Site Home The Web browser displays the Quantum Web site. To return to the Prism Management Console, click MC300 Prism Management Card User’s Guide...
Page 24
Chapter 1 Prism Management Console Using the Prism Management Console Interface MC300 Prism Management Card User’s Guide...
PMC. These Web pages are location in the navigational menu under Server Management MC300 Prism Management Card User’s Guide Chapter 2 allows you to configure the allows you to set or adjust...
Network Configuration Figure 2 Network Configuration Edit the configuration information as required (see MC300 Prism Management Card User’s Guide page allows you to view and change the page displays Network Configuration If the Web browser displays a dialog box prompting...
Table 3 Network Configuration Fields Click The PMC will not use the new configuration until it is rebooted (see MC300 Prism Management Card User’s Guide Field Description Use DHCP Select Use DHCP DHCP for dynamic IP addressing. In the event a DHCP server is unavailable, the other fields will apply.
Figure 3 Date and Time Configuration Use the pull-down boxes to change the date and time as necessary and click MC300 Prism Management Card User’s Guide to commit the changes to the PMC. Apply Date and Time Configuration page (see...
Viewing User Accounts User Name accounts. MC300 Prism Management Card User’s Guide page allows you to view, add, or delete user This authentication is designed for intranet use; passwords are transmitted as plain text and use over the Internet is discouraged unless a Virtual Private Network (VPN) is being used.
Under • A unique user name in the • The desired password in the Select the appropriate default groups are Administrator and Operator. MC300 Prism Management Card User’s Guide User Management , click Edit Users Edit , add the new user account information:...
Under The management frame displays the figure Under Click Click MC300 Prism Management Card User’s Guide Administrator allows access to all functions of the PMC. allows read-only access to the PMC. page indicates the account has been added. Results to return to the...
To access the Accessing Utilities Server Management displays the MC300 Prism Management Card User’s Guide page allows you to perform maintenance functions on page also allows you to reboot or shutdown the PMC. control allows the user to enter the...
Upload a New Software Image update the PMC operating software. Software Image Note: To upload a new software image: Access the MC300 Prism Management Card User’s Guide option is intended for the FSE to The user does not require access to Image Utilities Page.
To move the uploaded software image from the temporary area, Activating a New replace the current software image, and activate the new software Software Image image: Note: MC300 Prism Management Card User’s Guide Upload New Software Image Use the button to browse the system and Note: Browse locate the new software image.
The PMC reboots itself, including restarting and initializing the library. In a multiple frame environment, all libraries will be restarted and initialized. MC300 Prism Management Card User’s Guide Utilities Page. Activate New Software Image The activation process takes several minutes. Do Caution: not interrupt the process.
Follow the standard procedure to shut down the library. For more information on shutting down the library, refer to the appropriate library User’s Guide. MC300 Prism Management Card User’s Guide from the Shutdown Shutdown Prism Management Card page (see...
To view or edit the SNMP configuration of the PMC: In the navigation frame, under Configuration MC300 Prism Management Card User’s Guide allows you to set up information about page allows you to view and change the SNMP Configuration management settings used by the PMC.
• Warning Traps • Failure Traps • Available Traps • Unavailable Traps If necessary, enter trap destinations. MC300 Prism Management Card User’s Guide figure 8). Edit the configuration information as required table buttons provide a listing of the supported traps for...
Warning Traps Failure Traps Available Traps Unavailable Traps Trap Destination MC300 Prism Management Card User’s Guide Apply page indicates the configuration has been changed. Results to return to the SNMP Configuration Description View or set the library name for the...
Figure 9 Community Management MC300 Prism Management Card User’s Guide page displays a list of all the community settings configured for the PMC. To perform operations, SNMP management software must operation, the SNMP management software must...
Community Access the Under The management frame displays the figure MC300 Prism Management Card User’s Guide section of the page lists the currently Community Name An IP address or subnet mask set to Note: blank, indicates that IP-address-based access control is disabled.
• Enter a unique name in the • Enter an IP address in the • Enter a subnet mask in the MC300 Prism Management Card User’s Guide , enter the new community information: Add Community field holds up to 20 characters (a-z, A-Z). No special...
Access the Under The management frame displays the figure Under wish to delete from the list box. Click Click MC300 Prism Management Card User’s Guide • allows SNMP Read-only • allows both SNMP Read-write page indicates the community has been added.
Message Configuration Page for e-mail notification of various errors, failures, and activities. • E-mail Configuration Page information. MC300 Prism Management Card User’s Guide Chapter 4 ALERT E-mail allows you to set up information allows you set up the mailing lists...
To view or edit the contact configuration of ALERT E-mail: In the navigation frame, under Configuration The management frame displays the page (see MC300 Prism Management Card User’s Guide page presents two forms for contact figure 11 contact information is below the Note: Secondary primary contact information.
Figure 11 Contact Configuration If desired, insert or change the company information, or the primary or secondary library administrators (see MC300 Prism Management Card User’s Guide Note: Support Contract FSE during installation of the PMC. This field is read- only and may not be changed by the customer. All other fields can be entered by the customer.
Table 5 Contacts and Company Information Table 6 Library Administrator Information MC300 Prism Management Card User’s Guide No quotation marks ( “ ) or spaces are allowed when Note: entering telephone numbers or e-mail addresses. If spaces are entered, a message indicating appears.
Click Message Configuration Page Message Configuration • Control who in the company is notified of various types of library errors, failures, and activity • Select when to notify Quantum Customer Support MC300 Prism Management Card User’s Guide Field Description Pager...
Access the Click the down-arrow if Recipient A list of existing e-mail recipients for that message type is displayed. MC300 Prism Management Card User’s Guide Description Errors or failures not requiring onsite assistance, but may lead to future problems, such as: •...
Click the down arrow next to the desired message type. Click to highlight the e-mail address you wish to delete. Click Click MC300 Prism Management Card User’s Guide Message Configuration column of the page, enter the e-mail Add Recipient Send to Quantum?
Configuration Configuration Figure 13 E-mail Configuration Edit the configuration as required (see MC300 Prism Management Card User’s Guide page allows you to define the e-mail E-mail Configuration page displays (see E-mail Configuration If DHCP is enabled, the DHCP DNS address, if any, Note: will take precedence.
Test E-mail Sending a Test the e-mail configuration has been successfully completed. To E-mail verify the information, click Note: MC300 Prism Management Card User’s Guide Field Description Prism_Management_Console is the From E-mail Account default account. The name entered here must be a valid address on the e-mail...
• Event History Page allows you to view recent SNMP events for the library. MC300 Prism Management Card User’s Guide allows you to view and set the BUS allows you to view specific information allows you to perform various service...
Status Fields Frame / Level Drive Elevator Fixed Slot MC300 Prism Management Card User’s Guide page allows you to view the general status of page, click Home page contains library pictures and related This page remains blank while the PMC queries the library for status.
Field Hand Figure 14 Library Status, Part 1 MC300 Prism Management Card User’s Guide Chapter 5 ALERT Library Management Description Cartridge status in the hand Cartridge status of the bins. Bins appearing with a shaded area are designated as import/export bins from the front panel of the library.
Enter the desired position of the tape cartridge. Use the position as displayed in the fields below the Cartridge Movement section. Click Click MC300 Prism Management Card User’s Guide section of the figure 14 location of the tape cartridge. From...
The management frame displays the read-only Information drive (see Figure 16 Element Information MC300 Prism Management Card User’s Guide page. Library Status section of the graphic. Drive section of the page, click the...
Expired Cleaning Required Hardware Error Load Complete MC300 Prism Management Card User’s Guide Chapter 5 ALERT Library Management Description Displays the hexadecimal address of the element If a cartridge is present in the element and has a barcode, the barcode label displays. If a cartridge is...
The Library Configuration page allows you to view or configure the interface type and the BUS ID of the library and drives. Figure 17 Library Configuration, BUS ID Configuration MC300 Prism Management Card User’s Guide Description Displays status and whether the hand is available for operation Displays...
Location Interface BUS ID New BUS ID Caution: MC300 Prism Management Card User’s Guide Chapter 5 ALERT Library Management Description This field lists the SCSI devices within the library. This list includes the library robotic controller and the drives installed in the library. The library robotic controller is...
In the navigation frame, under click The management frame displays the (see Figure 20 Service Operations MC300 Prism Management Card User’s Guide Chapter 5 ALERT Library Management page allows you to perform various service page: Service Operations ALERT Library Management Service Operations.
To initialize the statistics functions of the library: Initializing Statistics In the Click Click MC300 Prism Management Card User’s Guide section of the page, select an area of the library: Selftest Check X-Axis Friction Check Y-Axis Friction Check Z-Axis Friction...
Wait for the library reset to complete before starting or resuming normal library operations. MC300 Prism Management Card User’s Guide to select the appropriate image file on the host Browse Before performing an upload, make sure there...
Configuration To set the monitoring interval time in minutes: Setting the Monitoring Interval In the number of minutes between monitors. MC300 Prism Management Card User’s Guide page allows you to set the Monitoring Configuration ALERT Library Management Monitoring Configuration figure 21).
If the status report is to be automatically sent, click the Report? Click has been saved. Click MC300 Prism Management Card User’s Guide Quantum recommends setting this to a non-zero Note: value to allow the library to monitor and detect system events and send ALERT E-mail notifications automatically as the events occur.
Time Stamp event occurred This information can be used as a log of the general service and usage of the library. MC300 Prism Management Card User’s Guide page (see Event History page includes information by: – the specific trap code –...
Page 73
Chapter 5 ALERT Library Management Event History Page Figure 22 Event History MC300 Prism Management Card User’s Guide...
Bridge Administration and software settings for the Fibre Channel bridges, and reboot or upload new firmware to one or all FC420 bridges. MC300 Prism Management Card User’s Guide Cabling the FC420s to the - allows you to configure the hardware...
Ethernet port on the PMC (ETH 1) to the Ethernet port on the FC420 bridge (see MC300 Prism Management Card User’s Guide These instructions call out specific Ethernet cables to be used with a 100 Mbit per second Ethernet hub/switch.
Figure 24 Cabling for a Single FC420 in an ATL M2500 MC300 Prism Management Card User’s Guide Chapter 6 Fibre Channel Management Cabling the FC420s to the PMC Ethernet cross-over cable MC300 PMC...
Ethernet hub/switch using a CAT-5 Ethernet cable (see The cabling procedure is complete. Figure 25 Cabling for Three FC420s in an ATL M2500 MC300 Prism Management Card User’s Guide If your Ethernet hub/switch includes an Uplink port, Note: do not use it. figure figure...
Two or More FC420s in an ATL M1500 Stack (Ethernet cables and hub/switch are not supplied, other standard cabling not shown for clarity) MC300 Prism Management Card User’s Guide Chapter 6 Fibre Channel Management MC300 PMC FC420 (one 100Mbit/second per library)
MC300 Prism Management Card User’s Guide Ethernet cables and hub/switches are not supplied, other standard cabling not shown for clarity For close up of the MC300 PMC and the FC420 bridge, see the “Cabling for a Single FC420 in an ATL M2500” illustration You will need one hub/switch port for the PMC and one hub/switch port for each FC420 bridge.
Do you want to continue? Click refreshing the route status. Caution: MC300 Prism Management Card User’s Guide page allows you to view and refresh the route , click Route Status page (see Route Status...
Table 12 Route Field Status Descriptions Device Bus:Target:LUN Vendor Product Status MC300 Prism Management Card User’s Guide table 12). Description The LUN assigned to the Fibre Channel port The SCSI device type using the LUN (available types are , and...
Loop ID, IP address, and bridge temperature; and software information such as firmware revision, connection mode, and NVRAM settings. MC300 Prism Management Card User’s Guide Chapter 6 Fibre Channel Management page allows you to view the hardware and...
Chapter 6 Fibre Channel Management Bridge Status Figure 29 Bridge Status The hardware and software status information within the table is defined below (see MC300 Prism Management Card User’s Guide table 13).
Fibre Connection Mode Data Rate Fibre Port transferring xxx MB/sec, xxx IOs/sec Extended Copy MC300 Prism Management Card User’s Guide Chapter 6 Fibre Channel Management Description Displays the status of the Fibre Channel port Displays the Loop ID entry for the Fibre...
LUN (view in the Auto Map takes approximately 60 seconds to refresh the map. Options (XCopy) feature. MC300 Prism Management Card User’s Guide page allows you to configure the page). Access the Bridge Status , click Bridge Administration Bridge Administration 30).
The new firmware becomes active after the reboot. Figure 30 Bridge Administration, Part 1 MC300 Prism Management Card User’s Guide Chapter 6 Fibre Channel Management - allows you to reboot one or all bridges. A bridge - installs new bridge firmware to one...
In the Navigation frame, under click Under Bridge Select a data rate from the The data rate types include: • • • MC300 Prism Management Card User’s Guide Bridge Administration Bridge Administration Set Fibre Channel Connection Mode pull-down list. Bridge Mode Loop Point-to-Point...
Enter the desired Click To configure a Route Map: Route Maps Note: Access the MC300 Prism Management Card User’s Guide Apply page displays indicating the data rate was Results Reboot the FC420 bridge to utilize the new Note: connection mode (see...
Click To configure a map from the bridge to its SCSI device: Auto Map Select a bridge from the Click MC300 Prism Management Card User’s Guide Bridge Administration Bridge FC LUN SCSI Bus page displays indicating the Route Map was...
In the Navigation frame, under click Select a specific bridge or Click Note: MC300 Prism Management Card User’s Guide Refreshing the map resets all SCSI devices on the Caution: bus. Therefore, do not use this feature when active backup and restore jobs are running.
Enter the name of the firmware image file or click the Browse button to select the firmware image file. Click successfully. MC300 Prism Management Card User’s Guide Bridge Administration Bridge Administration from the page displays indicating the file was uploaded...
Web page to open a Help new window and display online help for that Web page. The Internet browser opens a new window and displays the page (see figure 32). MC300 Prism Management Card User’s Guide Chapter 7 Getting Help Help...
Enable the trap types to be reported: Informational Warning , or . The button on the ALERT Failure Available Unavailable Details SNMP Configuration page also provides the supported traps for , and trap types. Informational Warning Failure MC300 Prism Management Card User’s Guide...
4004 Soft Error 4005 Soft Error 4006 Soft Error MC300 Prism Management Card User’s Guide Description Source is empty Destination is full Element address supplied is invalid Destination slot not present. Magazine or drive removed. Source slot not present. Magazine or drive removed.
Page 99
4019 Configuration Change 401A Operator Access MC300 Prism Management Card User’s Guide Description Unit attention – due to medium changed SCSI command had invalid field in CDB SCSI command had parameter list length error SCSI command had invalid field in parameter list...
Page 100
4400 Operator Access 4401 Operator Access 4402 Operator Access MC300 Prism Management Card User’s Guide Description Command failed due to reservation conflict SCSI bus reset received SCSI bus device reset message received SCSI abort message received SCSI parity error received...
Page 101
No mail generated 4411 No mail generated 4412 No mail generated MC300 Prism Management Card User’s Guide Description Door 3 open Door 4 open Door 1 closed (left door) Door 2 closed (right door) Door 3 closed Door 4 closed...
Page 102
No mail generated 4420 No mail generated MC300 Prism Management Card User’s Guide Description Magazine 1 has been inserted (left magazine) Magazine 2 has been inserted (right magazine) Magazine 3 has been inserted (left magazine) Magazine 4 has been inserted (right magazine)
Page 103
No mail generated 442E No mail generated MC300 Prism Management Card User’s Guide Description Magazine 5 absent at power-up (left magazine) Magazine 6 absent at power-up (right magazine) Magazine 7 absent at power-up (left magazine) Magazine 8 absent at power-up (right magazine)
Page 104
4448 No mail generated 4449 No mail generated MC300 Prism Management Card User’s Guide Description Drive 1 in this frame inserted Drive 2 in this frame inserted Drive 3 in this frame inserted Drive 4 in this frame inserted Drive 5 in this frame inserted...
Page 105
Soft Error 4460 Soft Error 4461 Soft Error MC300 Prism Management Card User’s Guide Description Drive 3 in this frame has powered-up Drive 4 in this frame has powered-up Drive 5 in this frame has powered-up Drive 6 in this frame has powered-up...
Page 106
447F Soft Error 4480 Soft Error MC300 Prism Management Card User’s Guide Description Cleaning cycle started on Drive 1 in this frame Cleaning cycle started on Drive 2 in this frame Cleaning cycle started on Drive 3 in this frame...
Page 107
4491 No mail generated 4492 No mail generated MC300 Prism Management Card User’s Guide Description Drive 6 in this frame is still requesting cleaning after being cleaned Module at level 1 in stack has been powered-down/ disconnected Module at level 2 in stack has been powered-down/...
Page 108
449F No mail generated 44A0 No mail generated MC300 Prism Management Card User’s Guide Description Level 1 fitted in stack Level 2 fitted in stack Level 3 fitted in stack Level 4 fitted in stack Level 5 fitted in stack...
Page 109
4680 Soft Error 4681 Soft Error 4682 Soft Error MC300 Prism Management Card User’s Guide Description Level 3 not fitted in stack Level 4 not fitted in stack Level 5 not fitted in stack Level 6 not fitted in stack...
Soft Error Soft Error Soft Error Soft Error MC300 Prism Management Card User’s Guide Description Drive 4 in this frame has rejected the cartridge. A reload is underway. Drive 5 in this frame has rejected the cartridge. A reload is underway.
Hardware Failure 202E Hardware Failure 202F Hardware Failure MC300 Prism Management Card User’s Guide Description Hand CV check found hand disconnected Servo CV check found servo board disconnected X axis CV check found X axis disconnected Y axis CV check found Y axis disconnected...
Page 112
240C Soft Error 240D Soft Error 240E Hardware Failure MC300 Prism Management Card User’s Guide Description Response packet received from drive 5 in this frame indicates command failed Response packet received from drive 6 in this frame indicates command failed...
Page 113
Soft Error 2613 Soft Error 261A Hardware Failure MC300 Prism Management Card User’s Guide Description The requested move cannot be performed The requested move cannot be performed Autoclean cannot be performed as there are no cleaning tapes Autoclean cannot be performed as all the cleaning tapes are in Demo unable to select random start slot.
Page 114
Soft Error 26BD Soft Error 26D8 Hardware Failure MC300 Prism Management Card User’s Guide Description The (nvr spec’d) xy build does not provide access to the cleaner slot The elevator vertical position is still unknown The inserted magazine has not been pushed fully home The elevator X axis offset is too great;...
Soft Error Soft Error Soft Error Soft Error MC300 Prism Management Card User’s Guide Description Attempt to initialize Drive 2 in this frame before it has become available Attempt to initialize Drive 3 in this frame before it has become...
Page 116
Soft Error Hardware Failure Soft Error Soft Error Soft Error MC300 Prism Management Card User’s Guide Description Directory data stored on tape has been corrupted The drive is ready for a periodic cleaning Invalid cleaning tape type used The drive requires preventive maintenance other than cleaning...
Page 117
0018 Hardware Failure 0019 Hardware Failure 001A Hardware Failure MC300 Prism Management Card User’s Guide Description A divide by zero exception has occurred A parity error has been detected on the address/data bus Out of memory _flsbuf was called _getbuf was called...
Page 118
Hardware Failure 2012 Hardware Failure 2013 Hardware Failure MC300 Prism Management Card User’s Guide Description Code attempted to write to address 0 Code attempted to execute at address 0 Code attempted to write to address 0 Code attempted to execute at address 0...
Page 119
2029 Hardware Failure 2100 Hardware Failure MC300 Prism Management Card User’s Guide Description Invalid byte received from drive 3 in this frame Invalid byte received from drive 4 in this frame Invalid byte received from drive 5 in this frame...
Page 120
Hardware Failure 2416 Hardware Failure 2500 Hardware Failure MC300 Prism Management Card User’s Guide Description Timed out waiting for I2C bus to go not busy No acknowledge received from slave Exceeded retry limit while trying to send message Message received from I2C bus but destination is unknown...
Page 121
Hardware Failure 260E Hardware Failure 260F Hardware Failure 2610 Hardware Failure MC300 Prism Management Card User’s Guide Description SCSI task received a bad message SCSI queue full FAS366 not detected Servo task init failed Servo queue full The X axis failed to get to its target position...
Page 122
2627 Hardware Failure 2628 Hardware Failure MC300 Prism Management Card User’s Guide Description The put action ‘completed’ with the cartridge still in the hand Command cannot be executed without first initializing the axis Theta nvr data has been corrupted, or not yet initialized...
Page 123
2683 Hardware Failure 2684 Hardware Failure MC300 Prism Management Card User’s Guide Description The Theta sensor closest to the right magazine failed to switch The Theta sensor closest to the left magazine failed to switch The X axis sensor could not be detected changing state...
Page 124
Hardware Failure 269B Hardware Failure 269C Hardware Failure MC300 Prism Management Card User’s Guide Description Drive 6 in this frame has reported a hardware error Drive 1 in this frame will not allow the hand to be operated as required...
Page 125
Hardware Failure 26AD Hardware Failure 26B0 Hardware Failure MC300 Prism Management Card User’s Guide Description Drive 6 in this frame hand failed to open Drive 1 in this frame is indicating ‘in flux,’ not ready for commands Drive 2 in this frame is indicating ‘in flux,’ not ready for commands Drive 3 in this frame is indicating ‘in flux,’...
Page 126
26CB Hardware Failure 26CC Hardware Failure MC300 Prism Management Card User’s Guide Description Drive 2 in this frame is indicating its hand is open and should have been closed Drive 3 in this frame is indicating its hand is open and should...
Page 127
2901 Hardware Failure 2902 Hardware Failure MC300 Prism Management Card User’s Guide Description Drive 6 in this frame has rejected the cartridge; cannot be loaded Drive 1 in this frame has failed to load the tape successfully Drive 2 in this frame has failed to load the tape successfully...
Page 128
Hardware Failure Soft Error Operator Access Hardware Failure Hardware Failure MC300 Prism Management Card User’s Guide Description Media can no longer be written or read, or performance is severely degraded The drive can no longer read data from the tape...
Caution qualified service personnel. If replacement is required, return the PMC to Quantum or an authorized Quantum service center. There is a danger of explosion if the battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the manufacturer.
Page 130
DS12B887 auf der Hauptplatine enthält eine Lithium-Batterie. Lithium gilt als speziell zu entsorgender Sondermüll. Bei der Entsorgung dieser Batterie müssen die entsprechenden lokalen, länder- und bundesweiten Gesetze und Regelungen betreffend Sammel- und Rückgabestellen beachtet werden. MC300 Prism Management Card User’s Guide...
Page 131
Denna produkt innehåller ett litiumbatteri. Dallas Semiconductor Varning! DS12B887 på moderkortet innehåller ett litiumbatteri. Litium kan betraktas som ett miljöfarligt ämne. När batteriet förbrukats, ska de lagar som gäller för miljöfarligt avfall respekteras. MC300 Prism Management Card User’s Guide Appendix B Battery Statements...
Page 133
DHCP assigning dynamic IP addresses on a network. With dynamic MC300 Prism Management Card User’s Guide This button causes the last updated PMC The browser frame that extends across the top of the...
Page 134
A distinct and separate section of a Web page, commonly Separate library modules connected through a common Field Service Engineer. A representative of Quantum who is The name of the server computer to which the library is The IP (Internet Protocol) address for the system. This A field used to sort data in database management systems.
Page 135
(PDUs), to different parts of a network. SNMP-compliant devices, called agents, store data about themselves in Management MC300 Prism Management Card User’s Guide The browser frame on the left of the screen A condition of the library in which the library is ready for...
Page 136
GUI and uses HTTP and other Internet protocols to communicate with Web servers. For example, Netscape Navigator and Internet Explorer are Web browsers. MC300 Prism Management Card User’s Guide The subnet mask determines the subnet to which the A program interrupt, usually caused by some exceptional Uniform resource locator.
Need help?
Do you have a question about the MC300 Prism and is the answer not in the manual?
Questions and answers