Invacare® LiNX
Flash
Fault Description
Code
1
Remote fault
2
Network or configuration fault
1
Motor 1
fault
3
1
Motor 2
fault
4
1
Motor 1
magnetic brake fault
5
1
Motor 2
magnetic brake fault
6
Module fault (other than remote
7
module)
1 Configuration of the motors depending on the power wheelchair model
22
Possible Action
Check cables and connectors.
l
Check other remotes, if installed.
l
Restart power wheelchair.
l
Check cables and connectors.
l
Recharge the batteries.
l
Check cables and connectors.
l
Check cables and connectors.
l
Check cables and connectors.
l
Check left magnetic brake is engaged.
l
Refer to the chapter "Pushing the Power Wheelchair in Freewheel Mode" in the
l
user manual of your power wheelchair.
Check cables and connectors.
l
Check right magnetic brake is engaged.
l
Refer to the chapter "Pushing the Power Wheelchair in Freewheel Mode" in the
l
user manual of your power wheelchair.
Check cables and connectors.
l
Check modules.
l
If the power wheelchair was stalled, reverse away or remove obstacle.
l
Contact your provider.
l
Check charger.
l
Contact your provider.
l
Contact your provider.
l
Contact your provider.
l
Contact your provider.
l
Contact your provider.
l
Recharge batteries.
l
Contact your provider.
l