Download Print this page
Rigol PIA1000 Series User Manual
Rigol PIA1000 Series User Manual

Rigol PIA1000 Series User Manual

Optical-fiber isolated probe

Advertisement

Quick Links

Advertisement

loading
Need help?

Need help?

Do you have a question about the PIA1000 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Rigol PIA1000 Series

  • Page 2 • RIGOL products are covered by P.R.C. and foreign patents, issued and pending. • RIGOL reserves the right to modify or change parts of or all the specifications and pricing policies at the company's sole decision. • Information in this publication replaces all previously released materials.
  • Page 3 7 Maintenance ........................23 7.1 Troubleshooting ..........................23 7.2 Care and Cleaning ..........................24 8 Appendix ...........................25 8.1 Appendix A: Order Information ....................8.2 Appendix B: Warranty ........................26 Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved. PIA1000 Series Optical-fiber Isolated Probe User Guide...
  • Page 4 List of Figures Figure 4.1 PIA1000 Series Optical-fiber Isolated Probe ..........8 Figure 4.2 Probe Size ........................ Figure 4.3 Electrical-Optical Converter ................Figure 4.4 Optical-Electrical Converter ................Figure 4.5 Probe Controller ....................11 Figure 4.6 Attenuating Tip ....................12 PIA1000 Series Optical-fiber Isolated Copyright ©RIGOL TECHNOLOGIES CO., LTD.
  • Page 5 Do not operate the product with covers or panels removed. Do Not Operate with Suspected Failures. If you suspect that there is damage to the product, have it inspected by RIGOL authorized personnel before further operations. Any maintenance, adjustment, or replacement to accessories must be performed by RIGOL authorized personnel.
  • Page 6 Safety Notices on the Product: • DANGER It calls attention to an operation, if not correctly performed, could result in injury or hazard immediately. PIA1000 Series Optical-fiber Isolated Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved. Probe User Guide...
  • Page 7 To avoid short circuit inside the instrument or electric shock, never operate the instrument in a humid environment. Altitude • Operating: below 3 km • Non-operating: below 12 km Equipment Type Test and measurement equipment. Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved. PIA1000 Series Optical-fiber Isolated Probe User Guide...
  • Page 8 Category IV is the three-phase at utility connection, any outdoor conductors. Environmental Considerations The following symbol indicates that this product complies with the WEEE Directive 2012/19/EU. PIA1000 Series Optical-fiber Isolated Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved. Probe User Guide...
  • Page 9 You can click on the following link to download the latest version of the RoHS&WEEE certification file. Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved. PIA1000 Series Optical-fiber Isolated Probe User Guide...
  • Page 10 This manual gives you a quick overview of the technical specifications and basic operation methods of the PIA1000 Series Optical-fiber Isolated Probe. http:// For the latest version of this manual, download it from RIGOL official website ( www.rigol.com Publication Number...
  • Page 11 The consigner or carrier shall be liable for the damage to the instrument resulting from shipment. RIGOL would not be responsible for free maintenance/rework or replacement of the instrument. 2. Check the probe In case of any mechanical damage, missing parts, or failure in passing the electrical and mechanical tests, contact your RIGOL sales representative.
  • Page 12 Product Overview Product Overview Introduction The PIA1000 Series Optical-fiber Isolated Probe offers exceptional performance and safety tests with its excellent common mode rejection capability and high isolated voltage. It achieves full-scale output in the differential mode voltage range from ±0.01 V to ±2500 V with various attenuating tips. The PIA1000 is powered over laser, offering a perfect solution for isolated power supply.
  • Page 13 Safety isolation test for high voltage, high bandwidth test applications • Wide voltage, wide band test applications • Floating measurements Probe Size The figure below shows the main body of the PIA1000 Series Optical-fiber Isolated Probe. 118 mm 40.6 mm 45 mm 28.7 mm 111.5 mm...
  • Page 14 The Electrical-Optical converter converts the electrical signal under test into an optical signal and transmits it via optical fiber to the Optical-Electrical converter. The Electrical-Optical converter of the PIA1000 series is powered over fiber, no additional power supply required. Figure 4.3 Electrical-Optical Converter...
  • Page 15 5. Type-C interface, used to connect the power source (PD, 12 V, 3 A) to power the probe. Using the Type-C interface to power the probe will disconnect the power supply from the oscilloscope. Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved. PIA1000 Series Optical-fiber Isolated Probe User Guide...
  • Page 16 50× attenuating tip with 1 GHz bandwidth TIP-MCX-1000X-1 1000× attenuating tip with 1 GHz bandwidth TIP-MCX-2000X-1 2000× attenuating tip with 1 GHz bandwidth TIP-MCX-5000X-1 5000× attenuating tip with 1 GHz bandwidth PIA1000 Series Optical-fiber Isolated Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved. Probe User Guide...
  • Page 17 • Do not block the heat dissipation port on the optical-electrical converter, otherwise the probe may be overheated and damaged. Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved. PIA1000 Series Optical-fiber Isolated Probe User Guide...
  • Page 18 1. Line up the notch of the attenuating tip with the hook of the E-O converter connector and insert the attenuating tip to the connector of the E-O converter. 2. Tighten the lock nut of the attenuating tip clockwise. PIA1000 Series Optical-fiber Isolated Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved. Probe User Guide...
  • Page 19 ( Before the connection, make sure that the locking lever of the probe controller is in the unlock position ( Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved. PIA1000 Series Optical-fiber Isolated Probe User Guide...
  • Page 20 8. Adjust the oscilloscope settings and proceed normal test. To Calibrate the Probe Before using the PIA1000 Series Optical-fiber Isolated Probe, you need to calibrate the probe. You can calibrate the probe either on the oscilloscope or on the probe controller.
  • Page 21 NOTE The specification of the PIA1000 series depends on the calibration of the probe. After the calibration is completed, the DC gain, offset voltage zero point, and offset gain are calibrated. After the probe is connected, you can check the probe information including the vendor, model, serial number, and the last calibration time on the probe setting menu.
  • Page 22 IEC60825-1 NOTE [1]: When the signal is much greater than the oscilloscope's system noise, it is recommended to use the oscilloscope's ±3 div DC signal. PIA1000 Series Optical-fiber Isolated Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved. Probe User Guide...
  • Page 23 500:1 ±250 V Adapters and Coaxial Cable Accessory Type Withstand Voltage Range MCX Adapter <3000 Vpp MMCX Adapter <300 Vpp MCX Coaxial Cable <3000 Vpp Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved. PIA1000 Series Optical-fiber Isolated Probe User Guide...
  • Page 24 +40℃ to +70℃, without condensation Non-operating Electrical-Optical converter: 5% to 85% RH (relative humidity) below +40℃; 5% to 45% RH at +40℃ to +70℃, without condensation PIA1000 Series Optical-fiber Isolated Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved. Probe User Guide...
  • Page 25 3000 meters Altitude Non-operating 12,000 meters Amplitude Frequency Characteristic Curve The figure above shows the amplitude-frequency characteristics of different probe models. Attenuating Tip CMRR Curve Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved. PIA1000 Series Optical-fiber Isolated Probe User Guide...
  • Page 26 Specifications The figure above shows the common mode rejection capabilities of different attenuating tips (0dB) at various frequencies. PIA1000 Series Optical-fiber Isolated Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved. Probe User Guide...
  • Page 27 Use an applicable attenuating tip. match the probe To Calibrate the Probe The probe needs Refer to to be calibrated calibrate the probe. Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved. PIA1000 Series Optical-fiber Isolated Probe User Guide...
  • Page 28 The probe is not waterproof and to avoid damage to the probe, do not expose it to sprays, liquids, or solvents. Avoid wetting the inside when performing exterior cleaning of the probe. PIA1000 Series Optical-fiber Isolated Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved. Probe User Guide...
  • Page 29 Probe Mount *1 Tripod mount to support the probe A list of all accessories for the optical-fiber Packing list *1 isolated probe Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved. PIA1000 Series Optical-fiber Isolated Probe User Guide...
  • Page 30 TIP-MCX-5000X-1 Appendix B: Warranty RIGOL TECHNOLOGIES CO., LTD. (hereinafter referred to as RIGOL) warrants that the product mainframe and product accessories will be free from defects in materials and workmanship within the warranty period. If a product proves defective within the warranty period, RIGOL guarantees free replacement or repair for the defective product.
  • Page 31 Appendix To get repair service, please contact your nearest RIGOL sales or service office. There is no other warranty, expressed or implied, except such as is expressly set forth herein or other applicable warranty card. There is no implied warranty of merchantability or fitness for a particular purpose.

This manual is also suitable for:

Pia1020Pia1050Pia1100