RIGOL products are covered by P.R.C. and foreign patents, issued and pending. RIGOL reserves the right to modify or change parts of or all the specifications and pricing policies at the company’s sole decision. Information in this publication replaces all previously released materials.
RIGOL General Safety Summary English Only the exclusive power cord Use the proper fuse. designed for the instrument Avoid circuit or wire exposure. and authorized for use within Do not operate the instrument with the local country could be suspected failures.
RIGOL Safety Symbols on the Product: English Hazardous Safety Protective Earth Chassis Ground Test Ground Voltage Warning Terminal Care and Cleaning Care Do not store or leave the instrument where it may be exposed to direct sunlight for long periods of time.
AC power, turn-on checkout, and remote control overview. For the latest version of this manual, download it from the official website of RIGOL (www.rigol.com). Format Conventions in this Manual Keys: The keys on the front panel are usually denoted by the format of "Key Name (Bold) + Text Box".
Page 7
RIGOL Content Conventions in this Manual English The RSA3000 series spectrum analyzer includes the following models. Unless otherwise specified, this manual takes RSA3045-TG as an example to illustrate the functions and operation methods of RSA3000 series spectrum analyzer. Model Frequency Range...
The consigner or carrier shall be liable for the damage to the instrument resulting from shipment. RIGOL would not be responsible for free maintenance/rework or replacement of the instrument. 2. Inspect the instrument...
Page 9
RIGOL English 14 13 12 11 10 Figure 1 Front Panel Table 1 Front Panel Description Description Description Numeric keyboard Menu softkeys TG output Back to previous menu page Utility function key area Function key area Page up/down key Help key...
Page 10
RIGOL English Figure 2 Rear Panel Table 2 Rear Panel Description Description Description AC power cord connector TRIGGER IN Fuse holder OCXO (option) USB DEVICE Handle USB HOST 10MHz IN HDMI 10MHz OUT IF OUT TRIGGER IN/OUT —— —— RSA3000 Quick Guide...
Page 11
RIGOL English 6 7 8 10 11 12 24 23 22 17 16 Figure 3 User Interface Table 3 User Interface Icons Name Description Reference level Displays the reference level value. Measurement Displays the current measurement results for result the marker (when no marker exists, the measurement results display frequency/span value).
Page 12
RIGOL detector. English Information : indicates messages, such as the prompt setting messages, alarm messages, and error messages. : indicates the speaker. You can tune it up and down to increase and decrease the speaker volume, or set it to mute : indicates the network settings.
Page 13
RIGOL Spectrum line Indicates the display area for the spectrum English display area line. Indicates the resolution bandwidth. The frequency range of the current sweep channel can be expressed by the combination Center or start of center frequency and span or the...
RIGOL To Prepare for Use English To Adjust the Supporting Legs You can unfold the supporting legs to use them as stands to tilt the instrument upwards for easier operation and observation. You can also fold the supporting legs for easier storage or shipment when the instrument is not in use.
RIGOL English CAUTION To avoid electric shock, ensure that the instrument is correctly grounded. Turn-on Checkout After connecting the instrument to the power source properly, press the Power on the front panel to start the spectrum analyzer. Then, you will see an initial splash screen.
RIGOL Basic Operations English Mouse/Keyboard/Touch Screen Operation Rule Mouse Operation Rule Connect the mouse (note that only the left-click operation is supported; the scroll and right-click operations with the mouse are not supported) to the spectrum analyzer via the USB HOST interface to perform the following operations: Click to select the menu and window.
Page 17
RIGOL Input Output Shift + i English Shift + g Cont Marker Shift + m Marker -> Shift + k Single Peak Shift + p Marker Function Shift + u Trigger Shift + r System Shift + y File Ctrl + f...
Page 18
RIGOL Touch Screen Operation Rule English RSA3000 has a 10.1-inch capacitive multi-touch screen that supports touch gestures. When operating on the menus other than the Marker menu: Tap the trace window, then slide left and right to modify the center ...
Page 19
RIGOL Enter Lower-level Menu (with parameter) English Press the corresponding menu key to enter the lower-level menu and change the currently selected option. The parameter type in the upper-level menu will be changed when you return to the upper-level menu again.
RIGOL Parameter Setting English You can enter the desired parameter values by using the numeric keys, the knob, or arrow keys on the front panel. Also, you can set the parameters by using the touch screen, the keyboard or the mouse. This section takes an example (set the center frequency to 800 MHz) to describe six methods of parameter setting.
Page 21
RIGOL English Figure 6 Arrow Keys Use the touch screen Touch the screen to select the function keypad icon at the upper-right corner. Then, the function keypad is displayed. Touch "FREQ"; Click Center Freq; Then the numeric keypad is displayed. Input 800, and select the desired unit "MHz".
RIGOL To Use the Built-in Help System English The built-in help system provides information about every function key on the front panel and every menu softkey. Get the built-in help information Press Help and a prompt message about how to obtain help information will be shown on the screen.
RIGOL Fuse Replacement English If you need to replace the fuse, use only the specified fuse (AC 250 V, T3.15 A) and perform the following operations: 1. Turn off the instrument, cut off the power, and remove the power cord.
RIGOL Working Mode Setting English RSA3000 provides three working modes: GPSA, RTSA, and EMI (option). Press Mode to select the working mode. Note: In different working modes, the functions of the keys on the front panel may be different. Press Help to display the help information of the current working mode.
Page 25
English RSA3000 provides various options to expand the function of the spectrum analyzer. If you need to purchase the option, please contact RIGOL sales representative. After you have purchased the option successfully, you will get the corresponding key. Then perform the following operations to install the option.
Instruments) commands. The RSA3000 series spectrum analyzer supports two ways of remote control: user-defined programming and PC software (e.g. RIGOL Ultra Sigma). When the instrument is in remote control, the keys (except the Power key and Esc) on the front panel are locked. At this time, you can press Esc to exit the remote mode.
For more information about this instrument, refer to the relevant manuals by logging in to the official website of RIGOL (www.rigol.com) to download them. RSA3000 User's Guide : introduces the functions of the instrument and the operation methods in GPSA and RTSA modes, remote control methods, possible failures and solutions in using the instrument, and order information.
Page 37
RIGOL 中文 图 2 后面板 表 2 后面板说明 编号 说明 编号 说明 AC 电源连接器 TRIGGER IN LAN 接口 保险丝座 OCXO(选件) USB DEVICE 接口 USB HOST 接口 手柄 HDMI 接口 10MHz IN 10MHz OUT IF OUT TRIGGER IN/OUT —— —— RSA3000 快速指南...
Page 42
RIGOL 基本操作 鼠标/键盘/触摸屏操作规则 鼠标操作规则 中文 您可通过 USB HOST 接口将鼠标连接至频谱分析仪 (注意, 仅支持鼠标左键操作; 不支持滚轮及鼠标右键) ,执行以下操作: 单击选择菜单及窗口。 长按左键可拖动网格上的显示数据或滑动条。 双击网格上的显示数据,数据回到右上角。 在Marker功能下,鼠标只支持移动光标,不支持增加光标。 键盘操作规则 您可通过 USB HOST 接口将键盘连接至频谱分析仪, 然后通过键盘快捷键代替仪 器前面板按键执行相应操作。 表 4 前面板按键与键盘快捷键关系 前面板按键 键盘快捷键 Mode Alt + o Mode Setup Shift + o Meas Alt + e...
Page 43
RIGOL Peak Shift + p Marker Func Shift + u Trigger Shift + r System Shift +y File Ctrl + f User Ctrl + u 中文 Recall Ctrl + r Save Ctrl + s Quick save Ctrl + Alt + q...