China as well as the I SO9001:2008 standard and the I SO14001:2004 standard. Other I nternational standard conformance certif ication is in progress. Contact Us I f you have any problem or requirement when using our products or this manual, please contact RIGOL. E-mail: service@rigol.com Websites: www.rigol.com DSA1000&DSA1000A Options&Accessories www.valuetronics.com...
RIGOL DSA1000&DSA1000A Options&Accessories Options and accessories provided by DSA1000&DSA1000A series spectrum analyzer are as shown in the table below. I f needed, please contact RIGOL or the local distributors. This manual only introduces the functions of some options. For the option with remark in the table below, refer to the dedicated manual.
Page 6
[ 2] For more details, refer to the corresponding manual (included in the option package in CD or hard copy form, or download the manual from www.rigol.com). DSA1000&DSA1000A Options&Accessories www.valuetronics.com...
RIGOL Preamplifier Turning on the preamplifier reduces the displayed average noise level in order to distinguish small signals from the noise when working with small signals. For the AMPT instruments supported option PA-DSA1030, pressing the front panel key RF Preamp corresponding menu will appear on the right of the screen.
RIGOL Advanced Measurement Functions Option AMK-DSA1000 provides plenty of advanced measurement functions including T-Power (Time domain Power), ACP (Adjacent Channel Power), Chan Pwr (Channel Power), OBW (Occupied Bandwidth), EBW (Emission Bandwidth), C/ N Ratio, Harmo Dist (Harmonic Distortion), TOI (Third Order I ntermodulation) and Pass/ Fail. The...
Page 9
RIGOL ACP ( Adjacent Channel Pow er) Measures the power of the main channel and the adjacent channels and calculates the power difference between the main and each of the adjacent channels. When enabled, both the span and resolution bandwidth of the analyzer are adjusted to be smaller automatically.
Page 10
RIGOL OBW ( Occupied Bandwidth) Calculates the power within whole bandwidth by integral operation and works out the occupied bandwidth by this value based on the specif ied power ratio. The center frequency difference between the measured channel and the analyzer will also be given in the measurement results.
Page 11
RIGOL C/ N Ratio Measures the power of both the carrier and the noise within specif ied bandwidth and calculates their ratio. Offset Freq Noise BW Carrier BW Harmo Dist ( Harmonic Distortion) Measures each order harmonic power and THD (Total Harmonic Distortion) of carrier.
Page 12
RIGOL TOI ( Third Order I ntermodulation) Measures the parameters of the TOI production generated by two signals which have the same amplitude and similar frequency. The measured results include the frequency and amplitude of the Base Lower, Base Upper, 3rd Order Lower and 3rd Order Upper signals, as well as the I ntercept of both the 3rd Order Lower and 3rd Order Upper signals.
RIGOL USB- GPI B I nterface Converter By using RIGOL USB-GPI B interface converter, the spectrum analyzer could be connected to a GPI B Bus Controller on PC. That is, the analyzer has been expanded GPI B interface and could f inish all sorts of work more easily through GPI B instructions.
RIGOL Lithium Battery ( China Only) The spectrum analyzer provides optional rechargeable battery. Please install the battery according to the method as shown in the f igure below. Use the Battery The battery status indicator at the front panel indicates the installation status and the current amount of electricity of the battery.
Page 15
RIGOL Battery Specifications Main Specifications Ratings Comments Conventional Capacity 15400 mAh 0.1 C Charging, 0.2 C ℃ Discharging (at 25± 2 Minimum Capacity 14100 mAh temperature) Conventional Voltage 11100 mV Power 147 Wh Material Lithium Battery Pack L× W× H 207mm×...
RIGOL Front Panel Cover The cover is provided to avoid damage to the front panel of the analyzer during transportation. Before putting your analyzer into action, remove the front panel cover by releasing latches at both sides, and sliding in the direction of the arrows as shown in the f igure below.
RIGOL Desk Mount I nstrument Arm Using an arm, the analyzer could be mounted on the workdesk to save your operation space. The height and angle of the instrument could be adjusted freely to acquire a supreme comfort and eff iciency making measurement and observation conveniently.
RIGOL Rack Mount Kit The analyzer could be installed in 19-inch standard machine cabinet, shown below. Kit Parts List Name Qty. Part Number Description Front Panel RM-DSA-1-01 Support Board RM-DSA-1-02 Left Plate RM-DSA-1-03 Right Plate RM-DSA-1-04 Fixed Figure RM-DSA-1-05 Rear Support Bar...
Page 20
RIGOL Space Requirements for I nstallation The following requirements must be fulf illed by the machine cabinet in which the instrument is mounted. Dimension of the machine cabinet must be standard 19-inch. At least 6U (266.7mm) space should be provided by the machine cabinet.
Page 21
RIGOL I nstallation Procedures A PH2 Phillips Screwdriver is recommended. Note that the instrument will be damaged or installed in rack incorrectly if the installation is not proper. Thus, only authorized operators can execute the installation operation. I nstall the right and left palate: aim the detents of right and left plate at the openings on support board and insert respectively, then f ix them using six M4 screws.
Page 22
RIGOL Fix the instrument: Fix a “Rear Support Bar” and two “Fixed Figure” on the instrument using four M4* 8 Screws. Locate the instrument on proper location and then f ixed the “Rear Support Bar” and “Fixed Figure” on the left/ right board and the Support Board using eight M4* 6 Screw.
Page 23
RIGOL Load into machine cabinet: mount the rack with instrument-f ixed into a standard 19-inch machine cabinet respectively using four M6 screws and square nuts. Notice: The rack holds a height of 6U, and the holes those in compliance with the arrow direction are the mounting holes for rack.
RIGOL Soft Carrying Bag The bag is designed by RIGOL for utility model measurement instruments. I t has reasonable structure as adopting some improvements according to the instrument and practical application. I t is in conformity with human engineering and could help you to carry instrument and its accessories easily with comforts and conveniences.
Page 25
RIGOL Held by shoulders Held by Neck&Waist Carried by Hand DSA1000&DSA1000A Options&Accessories www.valuetronics.com...
RIGOL Other Accessories Accessories along with the instrument are shown below. Note that the pictures here are for your reference only. Some differences may exist. Power Cord USB Cable [ 1] Quick Guide CDROM Front Panel Cover Note: [ 1] The CD contains User’s Guide...
Need help?
Do you have a question about the DSA1000 Series and is the answer not in the manual?
Questions and answers