Page 4
Neglecting maintenance or making changes to the setup of the machine can result in major hazards, including fire risk. While every effort has been made to ensure that the information in this manual is correct, Atlas Copco does not assume responsibility for possible errors.
Table of contents Preface 5.5.4 Engine operation ........25 5.5.5 Lights ............. 26 Please read the following instructions carefully before starting to use your light tower. Floodlight lux level ........27 Main parts - HiLight V4 ......6 It is a solid, safe and reliable machine, built Maintenance ..........
Main parts - HiLight V4 "The light tower provides an undercarriage ( frame, axle and towbar ) and 4 floodlights of 1000 W each or 4 LED floodlights of 350 W each. The light tower is very useful for construction sites where neither electricity nor lighting is available." - 6 -...
Contact with overhead from the unit and contact Atlas Copco. electrical power lines will cause serious injury or death. CAUTION - Do not position light - Ensure the trailer is well grounded, per all...
Engine safety CAUTION DANGER Operator safety Risk of severe burn. Asphyxiation hazard. - Before handling lights, - Operate the engine outdoors DANGER allow lights to cool for and keep away from engine 15 minutes. exhaust. Explosion hazard. - If operating in an enclosed - Keep engine, fuel, and other area, vent exhaust fumes to combustibles away from...
Service safety • Keep hands, feet, and loose clothing away from CAUTION moving parts on engine and generator. Risk of severe burn. • Keep the light tower and all its components clean. Before servicing - Do not touch the engine, •...
Labels Labels provide instructions and information. They also warn of hazards. For convenience and safety, keep all labels in legible condition, replacing labels when damaged or missing. Replacement labels are available from the factory. Samples of labels and their descriptions are provided in Table 1.1. Figure 1.1 Label locations - 11 -...
Assembly Tow hitch Assemble loose parts before use Notice There are 3 options for tow hitch. Check and unload loose parts before unloading units - Pintle hook from container. - 2-inch-ball • A - Drawbar with towing hitch ( option ) - Combo hitch for a 2-inch-ball and pintle hook •...
Operation Safety Towing and hoisting Before towing Before operating the light tower, read and be familiar with this instruction manual. Before towing, prepare the light tower as follows. Read and follow all safety instructions (see page 8). 1. Lower the light tower: a Verify the light tower mast is in the down CAUTION position and secured in place with the...
c Verify the rear and side levelling jacks are in the 2. Pull the locking pin and rotate the jack downward. up position, the outriggers are contracted, and When the jack is properly set, the locking pin all are secured with their locking pins. snaps into position with an audible “click.”...
Location Figure 3.2 Hoisting ring and forklift slots • To achieve the best possible light coverage, locate the light tower on the same level as the area to be lighted, or higher. • To reduce the risk of personal injury, ensure the surrounding area is in good order and free of debris.
Deployment the locking pin snaps into position with an audible d Connect the trailer ground stud to earth ground “click.” (see Figure 3.3). 7. Pull the jack locking pin and rotate the jack e Take the weather into account: do not raise or Levelling the trailer downward until the locking pin engages.
Page 23
2. To raise the tower, see Figure 3.5 and follow these instructions: a Remove the horizontal-lock pin from the transport cradle. b Rotate the handle of the drawbar-mounted winch to tighten the cable and raise the light tower mast. Figure 3.5 Raising the tower - 23 -...
Lowering the tower Before moving or storing the light tower, lower the mast and lock it in place. To lower the tower, see Figure 3.6 and use the following instructions. 1. Turn off the tower lights and the engine. For increased lamp life, allow the lights to cool for 15 minutes before proceeding.
Engine operation 3. When the glow-plug indicator light goes out, turn Starting the engine and hold the key at the START position. 1. Before starting the engine: 4. Release the key as soon as the engine starts, or after 10 seconds if the engine does not start. a Observe all engine safety precautions in page b Check engine oil, fuel, and coolant levels.
Stopping the engine • After the metal halide lamps are turned off, they Lamps that will not turn on will not turn on again until they are cool. The To stop the engine: If the lamps do not light when power is applied, lamps can take up to 15 minutes to cool.
Maintenance Daily inspection Lamp replacement c Remove the screws securing the flange rings and remove the flange rings. When the light tower is in regular use, the following To replace a light bulb (lamp), refer to Figure 4.1 and d Remove the protective lamp cover with the items should be checked daily: follow the instructions below.
Wiring diagrams Lamp Positioning DANGER Transport mode High voltage. • Horizontal position Contact with live electrical circuits will cause severe injury or death. Tilting • Turn off power before • Release the safety screw servicing any component • Rotate the lamps as per your desired position on the light tower.
Page 33
9829 3552 00-02 Applicable for HiLight V4, engine control circuit Preheat Start B(30) BR(AC) R1(19) C(17) R2(50) Notes, 1, When emergency stop switch is applied, this wire shall be replaced by switch wire 2. For standard and CE cubicles, wires should comply with CE. - 33 -...
Page 49
9829 3581 00-02 Applicable for HiLight V5+, engine circuit Notes, 1. For standard and CE cubicles, wires should be comply with CE 2. Other circuit refer to 9829355250 except 9829355250-02 - 49 -...
Page 50
9829 3552 60-01 Applicable for control circuit HiLight V4, Preheat Start B(30) BR(AC) R1(19) C(17) R2(50) Notes, 1, When emergency stop switch is applied, this wire shall be replaced by switch wire 2. Engine control circuit refer to 9829355200-01. 3. All wires comply with CSA. - 50 -...
Page 51
9829 3552 60-02 Applicable for HiLight V4, AC power circuit 120/240V 60Hz Notes, 1. Only for controller cubicle LC1003 MKII 2. All wires comply with CSA. - 51 -...
Page 52
9829 3552 60-03 Applicable for HiLight V4, lamp circuit 120/240V 60Hz With Longxin coil cord, wire color 51 and 53 are black; 56 and 58 are red; 52,54,57 and 59 are white; 55 is green/yellow; or with Philatron coil cord, wire color 51 is red; 53 is black; 56 is brown; 58 is orange; 52 is blue; 54 is yellow; 57 is purple; 59 is white; 55 is green. Line Line White...
Page 53
9829 3552 65-01 Applicable for ECU control circuit HiLight V5+, Preheat Start B(30) BR(AC) R1(19) C(17) R2(50) Notes, 1. When emergency stop switch is applied, this wire shall be replaced by switch wire 2. Control circuit see page 9829355250-01,9829355250-03 3. All wires comply with CSA - 53 -...
Page 54
9829 3552 65-02 Applicable for V5+, AC power circuit 120/240V 60Hz Notes, 1, Only for controller cubicle LC1003 MKII 2, All wires comply with CSA. - 54 -...
Page 55
9829 3552 65-03 Applicable for HiLight V5+, LED circuit 120V 60Hz only With Longxin coil cord, wire color 51 and 53 are black; 56 and 58 are red; 52,54,57 and 59 are white; 55 is green/yellow; or with Philatron coil cord, wire color 51 is red; 53 is black; 56 is brown; 58 is orange; 52 is blue; 54 is yellow; 57 is purple; 59 is white; 55 is green. Line White Load...
Safety Precautions • Check the wheel functioning - is free to rotate, and the wheel can not be detected with axial clearance. • Welding or drilling on shaft tube is not allowed. • Plug cotter pin. • Select the matching wheel hub: wheel offset, PCD Note: Adjust the bearing correctly.
Setting the Lc1003™ controller DOWN: Is used for navigating the Controller settings should only be instrumentation, event log and performed by a qualified technician. STOP: Is used to activate Stop/Reset configuration screens and to go to the mode. When pressing the STOP next parameter level.
Module display Icon overview Display Description Instrumentation icons Appears when the event log is Home page being displayed Display Description The home page is the page displayed when no other The default home page which Current time held in the unit page has been selected: displays Generator voltage and the Auto Run icon...
Front panel editor (FPE) / Auto Run icons Navigation menu Display Description To enter the navigation menu, press both the UP and Appears when the unit is in the Display Description DOWN buttons simultaneously. front panel editor. To navigate to the desired page, select the Appears when a remote start input corresponding icon by pressing the UP and DOWN is active...
To view the event log: Display Description 1. Press the UP and DOWN buttons simultaneously Event Log to display the navigation menu. 2. Once entered, cycle to the event log section (1) and enter. Event log 3. To view the event log, repeatedly press the UP or The Lc1003™...
Page 64
Menu flow Configuration Parameters – Scheduler Enable Scheduler On (1), Off (0) Schedule Run On or Off On (1), Load Off (0) Schedule Period Weekly (0), Monthly (1) Scheduler (1) 0:00:00 Start Time Scheduler (1) Start Day (1=Monday) Scheduler (1) 1,2,3,4 Start Week Scheduler (1) Duration...
Page 65
Setting the Lc1003™ clock Setting the Lc1003™ timer 907 Scheduler duration Set the desired time period. When this value is set, 1. Enter the weekly timer menu by pressing the 1. Enter the weekly timer menu as described above. Event 1 is closed. STOP and AUTO button simultaneously.
Page 66
Setting the sensitivity regulator There are 2 blinking levels: ASM (Auto Rise and Lower Safety Mast) The photocell sensitivity regulator is used for - Level 1: Slow blinking The ASM option provides the possibility to not only regulating the luminosity sensitivity level of the The photocell detects enough light, according to its switch on/off the floodlights automatically, but also photocell.
3002 6078 60 for the most important sub-assemblies, Atlas Copco has developed service kits that combine all wear parts. These service kits offer you the benefits of genuine parts, save on administration costs and are offered at reduces price, compared to the loose components. Refer to the parts list for more information on the contents of the service kit.
Page 68
Check rubber flexibles Check emergency stop Clean radiator Replace air filter element Check/Replace safety cartridge Inspection by Atlas Copco service technician Inspect starter motor Inspect waterpump Inspect alternator Check engine protective devices Check valve in the fuel return line (for mechanical injection system)
Page 69
Maintenance schedule for undercarriage Maintenance schedule (km) Notes Daily Every 500 Km Every 1000 km Every 2000 km Check tyre pressure Check tyres for uneven wear Check torque of wheel nuts Notes : (1) More frequently when operating in a dusty environment. (2) HiLight V4 add 2L oil, HiLight V5+ add 2.5L oil.
Page 70
Hilight V4 Hilight V5+ PAK & KIT AC PN PAK & KIT AC PN SERVICE PAK 200H 3002607610 SERVICE PAK 200H 3002607840 SERVICE PAK 400H 3002607620 SERVICE PAK 400H 3002607850 SERVICE PAK 800H 3002607630 SERVICE PAK 800H 3002607860 KIT: STEEL CABLE 3002608400 KIT: STEEL CABLE 3002608400...
Reference conditions 1) 4) Unit HiLight V4 50Hz HiLight V4 60Hz HiLight V5+ 50Hz HiLight V5+ 60Hz Power circuit Circuit-breaker 1.Number of poles 2.Thermal release 36.25 36.25 14.5 29 (b) (c) 3.Magnetic release 5..10xIn 5..10xIn 5..10xIn 5..10xIn Fault current protection 1.Residual current release 0.03 0.03...
Page 75
DERATING FACTOR LIGHT TOWER (%) 50 Hz 60 Hz LED 50/60 Hz For use of light tower outside these conditions, please contact Atlas Copco - 75 -...
Page 76
Options Spark arresters Tow hitch Towing hitch Combo IMPORTANT! There are 3 options for tow hitch. State and local safety codes specify that, in certain - Pintle hook locations, internal combustion engines that use - 2-inch-ball hydrocarbon fuels must be used with spark arrestors. - Combo hitch for a 2-inch-ball and pintle hook A spark arresters is a device constructed of For cambo hitch option only:...
Page 77
Towing hitch Ring 2.5 inch Road light system Cubicle ELCB with Universal socket 230V 50Hz Cubicle ELCB without socket 230V 50Hz E-Stop Control panels The light tower control panel comprises: • Circuit breakers for engaging power • An electrical receptacle for powering external equipment (Option) Cubicle with Universal socket •...
Need help?
Do you have a question about the HiLight V4 WUX and is the answer not in the manual?
Questions and answers