Page 1
WE-EF LEUCHTEN Installation and Maintenance Instructions Bollard KTX234 LED KTY234 LED Do not open during installation Surge Protection This product is factory-sealed. This product features built-in surge protection circuitry in compliance Refer to the instructions contained in this with applicable standards.
Page 2
Bollard KTX234 KTY234 KTY234 H = 270 mm H = 600 mm H = 1000 mm IP66, IK10, Class I, ta = 40°C Weight for KTX234 for KTY234 for KTY234 1000 Accessories: Planted root – Galvanised steel. ESV4 for KTX234/KTY234 300-0461 ESV4...
Light Source Maintenance Apart from cleaning the product’s exterior surfaces, no special maintenance work is required. Do not use high-pressure cleaners. To remove the head of the luminaire during maintenance, loosen screw J with Torx T-20 tool and rotate it anti-clockwise until it can be lifted up.
Installation The product must be installed and maintained by a building/construction and/or electrical regulations and relevant legislation. Warning: Notice: no longer be valid and shall become the full responsibility of the modifying person/organisation. Claims based on defects attributable to improper installation and/or application, and the consequences thereof, are excluded.
I. The direction of light for KTX [R65] is opposite the set screw J. 6) Connect luminaire cable E to mains supply cable F in watertight terminal connector G (not supplied by WE-EF): a) ON/OFF and Motion Stand-Alone (L = Phase, N = Neutral, = Earthing)
Page 7
5) Set cast base C in position and secure by inserting and tightening bolts I. 6) Connect luminaire cable E to mains supply cable F in watertight terminal connector G (not supplied by WE-EF): a) ON/OFF and Motion Stand-Alone (L = Phase, N = Neutral, = Earthing)
Page 9
Torque: Screw Torque max. 2.0 Nm max. 4.0 Nm max. 6.0 Nm set screw max. 15.0 Nm max. 100.0 Nm Direction of Light for [R65] One-sided Align the motion sensor to the desired detection area. TRANSVERSE AREA DETECTION Walking direction Detection area Bollard position...
Page 10
Principle wiring diagram – Wiring Scheme Eco Step Dim Motion Primary Secondary to the next 'Linked' luminaire Attention: L' is a switching phase. No external voltage must be applied here. All luminaires connected to L' must be connected to the same phase (e.g. L1). Failure to do so can result in damage to the luminaire and the motion detector.
Installation Instruction 1) Note: It is the responsibility to installer to 2) Please note, ESV4 and ESV6 must be ensure the suitability of the ESV/ESZ planted root for any local or national structural require- In both instances conduit entry can be rotated ments for installation, and that planted root is to match cable routing.
Page 16
5) For ESZ4 please orientate planted root as shown (base plate is parallel to the pathway). cal connections/conduit. For this installation, use 30 mm long M12 bolts for PSY planted root and 35 mm long M10 bolts for MRY planted root. M12 x 30 M10 x 35 7) Place the ESV/ESZ in the form work for con-...
Page 17
9) Pour concrete to desired level depending on requirement of concrete, paver or soil. Ensure (as per luminaire instructions) onto mounting level. Concrete Paver Soil...
Need help?
Do you have a question about the KTX234 LED and is the answer not in the manual?
Questions and answers