Download Print this page
SolaX Power X1 Series Quick Installation Manual
SolaX Power X1 Series Quick Installation Manual

SolaX Power X1 Series Quick Installation Manual

3.0kw-6.0kw
Hide thumbs Also See for X1 Series:

Advertisement

Quick Links

Quick Installation Guide
X1 Series 3.0KW-6.0KW
Packing Lists
I
Female DC connector * 2
Male DC connector * 2
Inverter
AC connector * 1
(with bracket)* 1
Positive DC pin contact * 2
Documents
Negative DC pin contact * 2
Wi-Fi dongle (optional),
LAN/GRPS dongle (optional)*1
* For the optional accessories, please be subject to the actual delivery.
II
- Unscrew the bracket from the back of the inverter.
- And mark the position(223 mm*30 mm) of three holes.
- Tighten the expansion
III
Cable size: 4 mm²
strip length:
Expansion bolt*3
Flat gasket*3
Self-tapping screw*3
Earth terminal*1
×
Inverter Installation
PH1 cross screwdriver; Torque: 0.8±0.1 N.m
bolt
s.
- Screw the expansion screws.
PV Connection
-Align the four halves connectors.
7.0 mm
positive DC
pin contact
negative DC
pin contact
cable
clamp contact
+
-
+
-
PV array
- Drill holes with φ10 drill.
- Depth: at least 60 mm.
- Match the inverter with the bracket.
- Screw the cross recessed screw on the right side.
- make sure available space
Torque: 0.8±0.1 N.m
300 mm
300 mm
300 mm
300 mm
300 mm
male plug
female plug
nut
tight nut
+
Note!
+
PV1
-
The PV connection
mode as the diagram
+
PV2
shown is not
-
-
allowed!
Inverter

Advertisement

loading
Need help?

Need help?

Do you have a question about the X1 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for SolaX Power X1 Series

  • Page 1 - And mark the position(223 mm*30 mm) of three holes. - Depth: at least 60 mm. PH1 cross screwdriver; Torque: 0.8±0.1 N.m Quick Installation Guide X1 Series 3.0KW-6.0KW - Match the inverter with the bracket. - Tighten the expansion bolt - Screw the expansion screws.
  • Page 2 AC Connection Firmware Upgrading 1) Make sure the DC switch is off and the AC is disconnected with grid. User can update the inverter system through the U-disk. outer jacket 52.5mm 2.Insert the stripped end of each three 1.Slide the cable nut and wires into holes in the female insert, strip length back shell onto the cable.

This manual is also suitable for:

X1-3.0kX1-3.3kX1-3.6kX1-4.2kX1-4.6kX1-5.0k ... Show all