pEllET sTOvEs usER MANuAl
UK
TEOREMA 5.0 - TEOREMA plus 5.0
MADE
IN
ITALY
design & production
004282318 - Rev 001

Advertisement

loading
Need help?

Need help?

Do you have a question about the TEOREMA 5.0 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Extraflame TEOREMA 5.0

  • Page 1 MANuAl TEOREMA 5.0 - TEOREMA plus 5.0 MADE ITALY design & production 004282318 - Rev 001...
  • Page 2 APPLY TECHNICAL DATA LABEL ENGLISH...
  • Page 3: Table Of Contents

    WarNINGS ........................................6 SafEty ..........................................6 routINE MaINtENaNcE ....................................8 INStaLLatIoN ........................................9 tEorEMa 5.0 dEtaILS ....................................11 tEorEMa PLuS 5.0 dEtaILS..................................12 Hot aIr ductING ......................................13 AdditionAl thermostAt to control the duct motor ...............................13 coMBuStIoN aIr ......................................13 oPEratIoN IN aIr ductING WItH tHErMoStat or ProBE (oPtIoNaL) ....................
  • Page 4 ENTfErNEN um SchÄdEN Zu VErmEIdEN ATENcIÓN - PErENTOrIO AdVArSEl - OBlIgATOrISk ANTES dE mOVEr lA ESTufA SAcAr lAS før du flYTTEr OVNEN, Bør du TAgE mAYÓlIcAS INdIcAdAS PArA EVITAr dAñOS. kErAmIkflISErNE Af fOr AT uNdgå SkAdEr. TEOREMA 5.0 - TEOREMA PLUS 5.0 ENGLISH...
  • Page 5 TEOREMA 5.0 - TEOREMA PLUS 5.0 ENGLISH...
  • Page 6: English

    We thank you for having chosen our company; our product is a great heating solution developed from the most advanced technology with top quality machining and modern design, aimed at making you enjoy the fantastic sensation that the heat of a flame gives, in complete safety. Warnings This instructions manual is an integral part of the product: make sure that it always accompanies the appliance, even if transferred to another owner...
  • Page 7 RECEIVED INSTRUCTIONS ON SAFE USE OF THE APPLIANCE AND THAT THEY UNDERSTAND THE INHERENT DANGERS. Š THE GENERATOR MUST NOT BE USED BY PERSONS (INCLUDING CHILDREN) WITH REDUCED PHYSICAL, SENSORY AND MENTAL CAPACITIES OR WHO ARE UNSKILLED PERSONS, UNLESS THEY ARE SUPERVISED AND TRAINED REGARDING USE OF THE APPLIANCE BY A PERSON RESPONSIBLE FOR THEIR SAFETY.
  • Page 8: Routine Maintenance

    (STRONG WIND, FREEzING) SAFETY SYSTEMS MAY INTERVENE THAT SWITCH THE GENERATOR OFF. IF THIS OCCURS, CONTACT THE TECHNICAL AFTER-SALES SERVICE AND ALWAYS DISABLE THE SAFETY SYSTEMS. Š IN THE EVENT THE FLUE CATCHES FIRE, USE SUITABLE SYSTEMS FOR SUFFOCATING THE FLAMES OR REQUEST HELP FROM THE FIRE BRIGADE.
  • Page 9: Installation

    InstallatIOn general The flue gas exhaust and hydraulic connections must be carried out by qualified personnel who must issue installation conformity documentation compliant with national standards. The installer must provide the owner or person acting for him, according to the legislation in force, with the declaration of conformity, supplied with: 1) the use and maintenance manual of the appliance and of the system components (such as for example, the smoke ducts, chimney, etc.);...
  • Page 10 In the presence of type B gas appliances with intermittent operation not intended for heating, they must have their own aeration and/or ventilation opening. The air inlets must meet the following requirements: Š they must be protected with grids, metal mesh, etc., but without reducing the net useful section; Š...
  • Page 11: Teorema 5.0 Details

    TEorEmA 5.0 DETAIls Ambient air outlet Pellet hopper Bulb thermostat reactivation On/Off Access to combustion chamber Combustion air inlet fuse and ash drawer 230V power supply Rear fumes exhaust Additional thermostat Upper fumes exhaust input TA Ambient probe ENGLISH...
  • Page 12: Teorema Plus 5.0 Details

    TEorEmA PlUs 5.0 DETAIls Room air outlet Air ducting Z2 outlet Air ducting Z2 additional thermostat input Access to combustion chamber Rear flue gas outlet and ash drawer Air ducting additional thermostat input Upper fumes exhaust Air ducting Z1 outlet Additional thermostat TA input Pellet hopper Combustion air inlet...
  • Page 13: Hot Air Ducting

    HoT AIr DUCTING The stove has 2 independent outlets for air ducting. Air ducting 1 - 2 are enabled by factory default. The pipe used for ducting the hot air must have an internal diameter of 80 mm and it must also be insulated or at least be protected against heat dispersion.
  • Page 14: Operation In Air Ducting With Thermostat Or Probe (Optional)

    oPErATIoN IN AIr DUCTING wITH THErmosTAT or ProBE (oPTIoNAl) The stove is fitted with an independent motor for ducting. The connection of an external thermostat or temperature probe (NTC 10K) in the input, located in the rear part of the stove, makes it possible to control the air ducting motor independently of the stove. Suffice it to connect the thermostat/temperature probe and set the desired temperature.
  • Page 15: Stove Positioning

    sTovE PosITIoNING To ensure the stove works correctly, it should always be positioned so that it is perfectly level, using a spirit level. NoTE For CorrECT oPErATIoN DURING IGNITION: Pellet hopper lid be sure to keep the fire door closed during the entire ignition phase. Otherwise, the stove will display "CLOSE HOPPER"...
  • Page 16: Pellets And Loading

    PELLETS AND LOADING Pellets are made by subjecting wood shavings i.e. the rejects of pure unpainted wood from sawmills, carpentry products and products from other activities connected to wood working and transformation, to very high pressures. This type of fuel is fully ecological as no glues are used for its compaction. In fact, pellet compactness is guaranteed over time by a natural substance found in wood: lignin.
  • Page 17: Remote Control

    Remote contRol The remote control can be used to adjust the main stove functions. Transmitter Select air mode Display Lock keyboard On/off stove (hold for 3 seconds) Degrees Celsius / Fahrenheit Set power Press the button once to enable or disable the chrono Set switch-off delay: The button allows to set the switch- off delay.
  • Page 18: Remote Control Icons

    Remote contRol Icons Air mode selected: Enable chrono Flashing QUIET Light on = activated On REGULAR Light off = deactivated Indicates the transmission of the radio signal Set switch-off delay On = during all radio communication Off = radio communication absent Battery low Keys locked Set power level.
  • Page 19: Control Board

    Control Board ViewiNg OF VariOus tO aCCess ON/OFF text messages tHe meNu ON/OFF OPeratiNg POwer temPerature ICon key indicates the presence of an alarm. indicates the status of the weekly programming Off: indicates that there are no alarms Off: deactivated. On: indicates the presence of an alarm On: activated.
  • Page 20: General Menu

    General menu go back - exit scroll parameters: next (3); previous (2) Change settings data: increase (4); decrease (5) Confirm - access menu MODES VENTILATION *AIR DUCTING Z1 **TEMPERATURE *AIR DUCTING Z2 **TEMPERATURE *AIR ZONE CONTROL EASY SETUP CHRONO ENABLING CHRONO MODE PRG1 SETTINGS...
  • Page 21: First Ignition Settings

    FIrst IGnItIon settInGs after connecting the power cord at the back of the generator, turn the switch (if any) to position (i). the switch is used to power the heat generator board. date-tIme this menu allows the date and time to be set. CONtrOLs PrOCeDure Š...
  • Page 22: Operation And Logic

    FLame guarD It Is ForBIdden to use tHe devICe wItHout tHe Flame Guard (see FIGure to tHe sIde). removal wIll ComPromIse tHe saFety oF tHe ProduCt and result In tHe ImmedIate nullIFICatIon oF tHe warranty PerIod. In tHe event oF wear or deterIoratIon, ask tHe aFter-sales servICe to rePlaCe tHe Parts (rePlaCement does not Fall wItHIn tHe ProduCt warranty as tHe Part Is suBjeCt to wear).
  • Page 23: Mode

    mode this menu is used to set the operating logic of the machine for the power used. range: (maNuaL, set temPerature, aux) By selecting maNuaL mode, the user can choose the heat output level delivered and the type of VeNtiLatiON, according to his/her preferences.
  • Page 24: Air Zone Control (Plus)

    aIr Zone Control (Plus) this menu allows you to enable the air ZONe CONtrOL mode range: (ON, OFF) if ON is selected, the stove will optimise the adjustments so that the heat is sent to the ducting when the main room temperature set is reached.
  • Page 25: Enabling

    enaBlInG allows the chrono and the different stove time slots to be enabled/disabled. CONtrOLs PrOCeDure Š Press key 6. Š Press 3 until CHrONO appears and confirm by pressing key 6. Š Confirm eNaBLiNg by pressing 6. Š use keys 4 -5 to enable (ON) or disable (OFF) Š...
  • Page 26: Example

    eXamPle CHrono tIme slot 02:00 08:00 16:30 23:00 MANUAL 02:00 08:00 16:30 23:00 Power start 02:00 time slot 1 Power 5 stop 23:00 start 08:00 02:00 08:00 16:30 23:00 time slot 2 Power 1 02:00 08:00 16:30 23:00 stop 16:30 22°C stove setting 02:00...
  • Page 27: Settings

    settInGs • DATE-TIME • LANGUAGE SEE ChApTER: FIRST IGNITION SETTINGS • DEGREES dIsPlay this menu allows you to adjust the brightness of the display. the values range from OFF, 1 to 20. if set to OFF, the display backlighting is set to maximum brightness and turns off after a 60 second delay.
  • Page 28: Delta-T

    delta-t this function allows the hysteresis thresholds to be set for stove ignition (DeLta-t ON) and switch-off (DeLta-t OFF), used as a room temperature adjustment interval if not managed by an external thermostat. the possible values for DELTA-T go from: 0.5 - 5°C CONtrOLs PrOCeDure Š...
  • Page 29: Additional Functions

    Š using the figure as a reference, connect the two thermostat cables (clean contact - no 230 V!). Š Connect the power to the stove again. Š set the set mODe to aux. TEOREMA 5.0 TEOREMA PLUS 5.0 pLEASE NOTE: ThE TERMINAL CAN bE FOUND IN ThE bAG INSIDE ThE STOvE.
  • Page 30: Cleaning And Maintenance

    TO FIND OUT WHERE YOUR NEAREST SERVICE CENTRE IS, CONTACT YOUR DEALER OR VISIT THE WEBSITE: WWW.LANORDICA-EXTRAFLAME.COM Cleaning and maintenanCe always follow the instruCtions in Complete safety! Š Make sure that the power cord is unplugged because the generator may have been programmed to switch on.
  • Page 31 burn pot and Combustion Chamber: Š Vacuum the residue in the burn pot Š Remove the burn pot completely from the relevant compartment; Š Vacuum the ash from the burn pot slot, ignition plug pipe holder and combustion chamber. Š Clear/clean all the holes in the burn pot. Š...
  • Page 32: Routine Maintenance Performed By Qualified Technicians

    BURN POT HOLES TO FIND OUT WHERE YOUR NEAREST SERVICE CENTRE IS, CONTACT YOUR DEALER OR VISIT THE WEBSITE: WWW.LANORDICA-EXTRAFLAME.COM routine maintenanCe performed by Qualified teChniCians routine maintenance must be performed at least once a year. Since the generator uses pellets as solid fuel, it requires annual routine maintenance, which must be performed by a Qualified technician, using only original spare parts.
  • Page 33 Cleaning the heat exChanger and inspeCtion Compartment * NOT SUPPLIED ENGLISH...
  • Page 34 TO FIND OUT WHERE YOUR NEAREST SERVICE CENTRE IS, CONTACT YOUR DEALER OR VISIT THE WEBSITE: WWW.LANORDICA-EXTRAFLAME.COM TEOREMA 5.0 THE IMAGES ARE FOR ILLUSTRATIVE PURPOSES. Fumes motor (dismantle and clean the smoke duct and "T"), new seal where required Gaskets, pellet hopper, inspections, ash drawer and door (replace and apply silicone where indicated)
  • Page 35 TO FIND OUT WHERE YOUR NEAREST SERVICE CENTRE IS, CONTACT YOUR DEALER OR VISIT THE WEBSITE: WWW.LANORDICA-EXTRAFLAME.COM TEOREMA PLUS 5.0 THE IMAGES ARE FOR ILLUSTRATIVE PURPOSES. Fumes motor (dismantle and clean the smoke duct and "T"), new seal where required...
  • Page 36: Displays

    Displays Display Reason Generator off sTaRT The start-up phase is in progress pelleT loaDinG Continuous pellet loading is in progress during the ignition phase iGniTion The ignition phase is in progress pRepaRaTion The preparation phase is in progress WoRk The normal work phase is in progress MoDulaTion The generator is working at minimum final cleaninG...
  • Page 37 Turn the stove off using key 6 and repeat the procedure No power during the ignition described in the "iGniTion" chapter. iGniTion - black ouT phase. Other reset operations should be performed by an authorised technician. coMManD auGeR Abnormal pellet loading. Contact after-sales centre alaRM Differential pressure transducer faulty or...
  • Page 38: Disposal

    Disposal InformatIon for management of electrIc and electronIc applIance waste contaInIng batterIes or accumulators This symbol, which is used on the product, batteries, accumulators or on the packaging or documents, means that at the end of its useful life, this product, the batteries and the accumulators included must not be collected, recycled or disposed of together with domestic waste. Improper management of electric or electronic waste or batteries or accumulators can lead to the leakage of hazardous substances contained in the product.
  • Page 39 ENGLISH...
  • Page 40 ExtraflamE S.p.a. Via Dell’Artigianato, 12 36030 - MONTECCHIO PRECALCINO (VI) - ITALY   +39.0445.865911 -  +39.0445.865912 -  info@extraflame.it - www.lanordica-extraflame.com MADE ITALY design & production TO FIND THE SERVICE CENTRE NEAREST TO YOU CONTACT YOUR DEALER OR CONSULT THE SITE WWW.LANORDICA-EXTRAFLAME.COM...

This manual is also suitable for:

Teorema plus 5.0