Extraflame VIRNA IDRO User Manual

Extraflame VIRNA IDRO User Manual

Hide thumbs Also See for VIRNA IDRO:

Advertisement

THERMO PRODUCTS USER MANUAL
UK
VIRNA IDRO
MADE
IN
ITALY
design & production
004276851 - ReV.002

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VIRNA IDRO and is the answer not in the manual?

Questions and answers

Summary of Contents for Extraflame VIRNA IDRO

  • Page 1 THERMO PRODUCTS USER MANUAL VIRNA IDRO MADE ITALY design & production 004276851 - ReV.002...
  • Page 2 ENGLISH...
  • Page 3: Table Of Contents

    FumEs EXHaust sYstEm............................................9 HydrauLIc SyStEM ...................................... 10 instaLLation anD saFEtY DEVicEs ......................................10 aNtI-coNdENSatIoN dEVIcE (MaNdatory) ............................11 VIrNa Idro dEtaILS ..................................... 12 fEaturES........................................13 cHEckS aNd MEaSurES for coMMISSIoNING ............................13 tHE pELLEt LoaD motor DoEs not Function: ..................................13 buLb tHErmostats - rEarm ..........................................13...
  • Page 4 ATTENZIONE TASSATIVO PrImA dI mOVImENTArE lA STufA TOglIErE Il rIVESTImENTO INdIcATO PEr EVITArE dANNI. WArNINg BEfOrE hANdlINg ThE STOVE, ThE cOVErINg INdIcATEd muST BE rEmOVEd TO AVOId dAmAgE. ATTENTION ImPÉrATIf AVANT dE dÉPlAcEr lE POêlE, rETIrEr lE rEVêTEmENT INdIquÉ POur ÉVITEr TOuT dOmmAgE. AchTuNg PflIchT BEVOr dEr OfEN BEWEgT WIrd, muSS dIE ANgEZEIgTE VErklEIduNg ENTfErNT WErdEN, um SchädEN Zu VErmEIdEN.
  • Page 5: English

    We thank you for having chosen our company; our product is a great heating solution developed from the most advanced technology with top quality machining and modern design, aimed at making you enjoy the fantastic sensation that the heat of a flame gives, in complete safety. Warnings This instructions manual is an integral part of the product: make sure that it always accompanies the appliance, even if transferred to another owner or user, or if transferred to another place.
  • Page 6: Routine Maintenance

    DISABLED PERSONS. Š THE HEARTH DOOR MUST ALWAYS BE CLOSED DURING NORMAL FUNCTIONING OF THE PRODUCT. Š WHEN THE APPLIANCE IS FUNCTIONING AND HOT TO THE TOUCH, ESPECIALLY ALL EXTERNAL SURFACES, ATTENTION MUST BE PAID Š CHECK FOR THE PRESENCE OF ANY OBSTRUCTIONS BEFORE SWITCHING THE APPLIANCE ON FOLLOWING A PROLONGED PERIOD OF INACTIVITY.
  • Page 7: Installation

    InstallatIon general The flue gas exhaust and hydraulic connections must be carried out by qualified personnel who must issue installation conformity documentation compliant with national standards. the installer must provide the owner or person acting for him, according to the legislation in force, with the declaration of conformity, supplied with: 1) the use and maintenance manual of the appliance and of the system components (such as for example, the smoke ducts, chimney, etc.);...
  • Page 8 In the presence of type B gas appliances with intermittent operation not intended for heating, they must have their own aeration and/or ventilation opening. The air inlets must meet the following requirements: Š they must be protected with grids, metal mesh, etc., but without reducing the net useful section; Š...
  • Page 9: Hermetically Sealed Installation

    Hermetically sealed installation Virna Idro is a fully sealed product with respect to the environment in which it is installed. This means that it is ideal for passive houses because it does not take air in from within the house.
  • Page 10: Hydraulic System

    Standards in force, national, regional and municipal, as well as these instructions. For Italy, installation must be carried out by professionally qualified staff (Ministerial Decree dated 22.01.08 n°37). Extraflame S.p.A. declines all responsibility for damage to objects and/or persons caused by the system. TYPE OF SYSTEM Š...
  • Page 11: Anti-Condensation Device (Mandatory)

    DISTANCES OF SAFETY DEVICES ACCORDINg TO THE STANDARD The temperature safety sensors must be in place on the machine at a distance no greater than 30 cm from the flow connection. Whenever the generators lack a device, those missing can be installed on the generator flow pipe, within a distance no greater than 1 m from the machine. COMMISSIONINg CHECkS Before connecting the boiler: a) wash all system piping thoroughly in order to remove any residues which might compromise the correct functioning of certain system...
  • Page 12: Virna Idro Details

    Virna idro details Heat exchanger scrapers Display External door handle Pellet hopper pressurised closure Upper fumes exhaust Lower fumes exhaust Lateral fumes exhaust Combustive air rear inlet On/Off Power supply 220v fuse Combustive air side inlet Hydraulic installation 3 bar safety drain...
  • Page 13: Features

    features Water content of the thermo-product heat exchanger (l) volume of expansion vessel integrated into thermo-product (l) 3 bar safety valve integrated into the thermo-product Minimum and maximum pressure switch integrated into the thermo-product Pump integrated into the thermo-product Pump max. head (m) Envision any inTEgraTivE Expansion vEssEl on ThE Basis of ThE sysTEm WaTEr conTEnT.
  • Page 14: Stove Positioning

    stoVe positioning To ensure the stove works correctly, it should always be positioned so that it is perfectly level, using a spirit level. note for correct operation Pellet hopper lid The following indications must be respected for correct pellet stove operation: During stove operation, the pellet hopper lid and the door must always be closed.
  • Page 15: Pellets And Feeding

    Pellets and feeding Pellets are made by subjecting wood shavings i.e. the rejects of pure wood (without paint) sawmill, carpenter products and products from other activities connected to working and transforming wood, to very high pressures. This type of fuel is fully ecological as no glues are used to hold it together. In fact, the compactness of the pellets is guaranteed over time by a natural substance that is found in wood: wood coal.
  • Page 16: Control Board

    Control Board ON/OFF BUTTON ViewiNg OF VariOUs TO aCCess TexT messages THe meNU aDJUsTmeNT seTTiNgs wOrKiNg TemPeraTUre TemPeraTUre display iCons key indicates radio signal reception indicates modulation of the stove Led off: radio communication not available. Led on: the stove is working at the set power Led on: radio communication available.
  • Page 17: General Menu

    General menu go back - exit scroll parameters: next (2); previous (3) modify data settings: increase (4); decrease (5) Confirm - access menu EASY SETUP CHRONO ENABLING PRG1 PRG2 SETTINGS dATE-TImE PRG3 LANGUAGE PRG4 dISPLAY STANd-BY FIRST LOAd OUTLET AIR dEGREES RESET *STOVE STATUS...
  • Page 18: Remote Control

    remote Control The remote control allows you to adjust all the functions that are normally possible with the LCD display. The various functions are outlined in detail in the table below: on/off Prolonged pressure turns the stove on or off. power inCrease increases operating power power deCrease...
  • Page 19: Commissioning Settings

    CommissioninG settinGs Once the power cable at the back of the stove has been connected, move the switch, also located on the back, to (I). The switch at the back of the stove powers the stove board. The stove remains off and a first screen appears on the panel reading OFF . line frequenCy 50/ 60hz if the generator is installed in a country with a frequency of 60Hz, the display will show "POwer FreQ.
  • Page 20: Operation And Logic

    operation and loGiC iGnition Once the points listed previously have been checked, press key 1 for three seconds to ignite the stove. 15 minutes are available for the ignition phase. after ignition and having reached the control temperature, the stove interrupts the ignition phase and passes to sTarTiNg. preparation During the start-up phase, the stove stabilises combustion, increasing it progressively, to then start ventilation and pass on to wOrK.
  • Page 21: Additional Thermostat

    additional thermostat n.B. : installation must Be performed By an authorised teChniCian There is a possibility to control the temperature of a room adjacent to the room where the stove has been placed; simply connect a thermostat following the procedure described in the following section (it is advisable to place the optional mechanical thermostat at a height from the ground equal to 1.50m).
  • Page 22: Easy Setup

    easy setup The volumetric weight of the pellet is the ratio between the weight and the volume of the pellet. This ratio may change while keeping the quality of the pellet unchanged. By using the easY seTUP function, it is possible to change the calibration of the volumetric weight by increasing or decreasing the pre-set values.
  • Page 23: Enabling/Disabling The Chrono

    enaBlinG/disaBlinG the Chrono CONTrOLs PrOCeDUre Š Press key 6. Š Press key 3 until CHRONO appears and confirm by pressing key 6. Š Confirm ENABLING with key 6. Š Use keys 4 and 5 for enabling (ON) or disabling OFF) Š...
  • Page 24 EXAmPLE OF CHRONO OVERLAPPING TImE/SLOTS Time slot 02:00 02:00 08:00 08:00 16:30 16:30 23:00 23:00 set power 02:00 02:00 08:00 08:00 16:30 16:30 23:00 23:00 set temperature 72° 72° 68° 68° 02:00 02:00 08:00 08:00 16:30 16:30 23:00 23:00 start 02:00 Time slot 1 power 3 - set temp 72°C stop 23:00...
  • Page 25: Settings

    settinGs • date-time • lanGuaGe See chapter: commiSSioning SettingS. • set deGrees dISPLAY This menu allows you to adjust the brightness of the display. The values range from OFF, 1 to 20. if set to OFF, the display backlighting is set to maximum brightness and then, turns off after a 60 second delay.
  • Page 26: Outlet Air

    OUTLET AIR This function allows any air in the stove to be discharged. By activating the pump function, it will be powered alternatively with 30 second work phases and 30" stop for 15 minutes. with the stove cold and in "OFF", activate the OUTLET AIR function, pressing key 6 to confirm. To interrupt, press and hold key 1 for 3 seconds.
  • Page 27: Cleaning And Maintenance

    TO FIND OUT WHERE YOUR NEAREST SERVICE CENTRE IS, CONTACT YOUR DEALER OR GO TO THE WEBSITE: WWW.LANORDICA-EXTRAFLAME.COM Cleaning and maintenanCe Follow the instruCtions always in Complete saFety! Š Make sure that the power supply cable plug is disconnected, since the generator could be programmed to switch-on.
  • Page 28 every day burn pot and Combustion Chamber: Š Remove the pellet chute assembly completely, emptying any ash reside from the burn pot below. Š Remove the burn pot, emptying any ash residue from the ash drawer below. Š Suck the ash of the combustion chamber and spark-plug pipe holder.
  • Page 29 every 30 days Cleaning the Combustion Chamber deFleCtor Remove the deflector and eliminate the ash deposited in the upper part of the deflector. ENGLISH...
  • Page 30: Burn Pot Detail

    the gaskets For the pellet hopper, burn pot and Fire door ensure that the stove works properly. it is neCessary to periodiCally CheCk them; iF they seem to be worn or damaged, they must be replaCed immediately. these operations must be Carried out by a QualiFied teChniCian. a Clean burn pot guarantees CorreCt operation! by making sure the burn pot and its holes are always Clean From any Combustion residue, exCellent Combustion by the generator is...
  • Page 31: Routine Maintenance Performed By Qualified Technicians

    IT IS ADVISABLE NOT TO DISCONNECT THE GENERATOR FROM THE POWER SUPPLY TO ALLOW THE PUMP TO CARRY OUT THE NORMAL ANTI-BLOCK CYCLES. Routine maintenance must be performed at least once a year. TO FIND OUT WHERE YOUR NEAREST SERVICE CENTRE IS, CONTACT YOUR DEALER OR GO TO THE WEBSITE: WWW.LANORDICA-EXTRAFLAME.COM ENGLISH...
  • Page 32 routine maintenanCe THE iMAGES ARE foR illUSTRATiVE PURPoSES onlY. Fumes motor (disassembly and cleaning and fumes and "T" pipes), new silicone in the points envisioned Inspections of gaskets, pellet hopper, ash drawer and door (replace them and apply silicone where envisioned) Combustion chamber and heat exchanger (full cleaning) including ignition-plug pipe Hopper (complete emptying and cleaning) and check gasket.
  • Page 33 routine maintenanCe THE iMAGES ARE foR illUSTRATiVE PURPoSES onlY. Fumes motor (disassembly and cleaning and fumes and "T" pipes), new silicone in the points envisioned Inspections of gaskets, pellet hopper, ash drawer and door (replace them and apply silicone where envisioned) Combustion chamber and heat exchanger (full cleaning) including ignition-plug pipe Hopper (complete emptying and cleaning) and check gasket.
  • Page 34: Displays

    Check pellet feed (see “EASY SETUP”), if the problem cannot be solved, HoT fuMes High fumes temperature contact an authorised technician. TO FIND OUT WHERE YOUR NEAREST SERVICE CENTRE IS, CONTACT YOUR DEALER OR GO TO THE WEBSITE WWW.LANORDICA-EXTRAFLAME.COM ENGLISH...
  • Page 35 IPWM output interface damaged, in short Contact after-sales centre alaRM circuit or not connected * if there is an additional system data-sheet. TO FIND OUT WHERE YOUR NEAREST SERVICE CENTRE IS, CONTACT YOUR DEALER OR GO TO THE WEBSITE WWW.LANORDICA-EXTRAFLAME.COM ENGLISH...
  • Page 36: Guarantee Terms

    Extraflame S.p.A. cannot be held liable for injury or damage which may - either directly or indirectly - be caused to persons, animals and property ensuing from failure to observe all the instructions provided in the relevant instruction manual and the warnings regarding installation, use and maintenance of the product, that can also be downloaded on the website.
  • Page 37 AddITIONAL wARNINGs Š Only use the fuel recommended by the manufacturer. The product must not be used as an incinerator. Š Do not use the product as a ladder or supporting structure. Š Do not place laundry on the product to dry it. Any clothes-horse or similar objects must be kept at due distance from the product. Danger of fire or damage to the coating.
  • Page 38 ENGLISH...
  • Page 39 ENGLISH...
  • Page 40 Extraflame S.p.A. Via Dell’Artigianato, 12 36030 - MONTECCHIO PRECALCINO (VI) - ITALY   +39.0445.865911 -  +39.0445.865912 -  info@extraflame.it - www.lanordica-extraflame.com MADE ITALY design & production TO FIND THE SERVICE CENTRE NEAREST TO YOU CONTACT YOUR DEALER OR CONSULT THE SITE WWW.LANORDICA-EXTRAFLAME.COM...

This manual is also suitable for:

001282600001282601

Table of Contents