INSTRUCTION MANUAL
ROOM PRESSURE
RL1 MM Pa
SQUARE DP INDICATOR
www.utplindia.in
www
Model No. : UT-1401
HI
LO COM
UP
ENTER
MODE
ROUND DP INDICATOR
DP INDICATOR
RL1 MM Pa
HI
LO COM
UP
ENTER
MODE
RL1 MM
Pa
HI
LO COM
UP
ENTER
MODE
+91 7046223333 , 9427301436
WITH
SENSOR
005 5
Low
.
High
Com.
Mm WC
Pascal
M
MODEL NO:UT-1401
www.unitechinstrument.com
EXTERNAL FLP ENCLOSURE
@
sales@utplindia.in

Advertisement

loading
Need help?

Need help?

Do you have a question about the UT-1401 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Unitech UT-1401

  • Page 1 INSTRUCTION MANUAL Model No. : UT-1401 ROOM PRESSURE DP INDICATOR WITH SENSOR RL1 MM Pa LO COM ENTER MODE 005 5 High Com. Mm WC Pascal RL1 MM Pa LO COM RL1 MM LO COM ENTER MODE MODEL NO:UT-1401 ENTER MODE www.unitechinstrument.com...
  • Page 2 12 / 24 VDC – a switch, fuse (1A, 125A) or a circuit breaker. The above items should be installed together with UT-1401 for the products electrical protection. The switch, Fuse or circuit-breaker should be located close to the controller, within easy reach operator.
  • Page 3: Table Of Contents

    DP INDICATOR AND SENSOR UT-1401 CONTENTS OVERVIEW ....................INTRODUCTION ..................NSTALLATION ........................................MOUNTING ....................EXTERNAL DIMENSION ....................TECHNICAL SPECIFICATIONS ....................WIRING DIAGRAM PROGRAMMING ..................................OPERATION INTERFACE ..............MODE ACCESS FLOW CHART OPERATIONAL MODES ................................CONFIGURATION MODE ....................
  • Page 4: Overview

    Parameters can also be hidden to user to prevent improper configuration of the unit Mount Anywhere The UT-1401 product group is Process control instruments that must be panel mounted. The wiring terminals must be provided. the UT-1401 is environmentally hardened and, if suitably handled, can be mounted virtua -lly anywhere in plant or factory;...
  • Page 5: Technical Specifications

    DP INDICATOR AND SENSOR UT-1401 Technical Specifications TECHNICAL SPECIFICATIONS Nos Of Input 1 Nos (DP) Integral Or Remote (external) Temperatures Input Input DP Input Integral Or Remote (external) 24V/5V DC @ 30mA max, Isolated from Input & Output Transmitter Power Supply...
  • Page 6: Wiring Diagram

    DP INDICATOR AND SENSOR UT-1401 Wiring Diagram CAUTION WIRING CONSIDERATION SQUARE DESIGN ROUND DESIGN Shielded twisted pair wire is used for all analog I/P, Process sensors RTD, Thermo-couple, mV-mA DC, Volt DC, Linear input and Communication. AILURE TO COMPLY WITH THESE INSTRUCTION MAY RESULT COMM.
  • Page 7: Programming

    DP INDICATOR AND SENSOR UT-1401 PROGRAMMING Operation Interface DP Display High Alarm Pascal Unit Selected LED Low Alarm mmWC Unit Selected LED COM LED Relay Status LED MODE Key PASS Key ENTER Key UP Key NORMAL VIEWS 1. 7 segment Display 4 Digit 7 segment dedicated to display the present value.
  • Page 8: Mode Access Flow Chart

    DP INDICATOR AND SENSOR UT-1401 Mode Access Flow Chart. Configuration Change Normal Mode [PV] Setup Calibration Mode Mode Password Mode Mode Mode Selection Press key to enter into the Programming mode from Normal mode Any New Password NOTE : Default Password will be Protected Parameter Password will be These are the whole parameter list.
  • Page 9: Operational Modes

    DP INDICATOR AND SENSOR UT-1401 OPERATIONAL MODES Configuration Mode ‘Configuration Mode’ will shown by pressing key, will be display and then by pressing Range / Values Display Parameter CONFIGURATION MODE Range : Values between Password for Config. Mode Parameters Scroll the digit by key, Increase by key.
  • Page 10 DP INDICATOR AND SENSOR UT-1401 Continue Configuration Mode Range / Values Display Parameter BAUD RATE [COMMUNICATION] Values : : Baud Rate 4800 Baud Rate for Communication : Baud Rate 9600 : Baud Rate 19200 Change value by key, or by key.
  • Page 11: Setup Mode

    DP INDICATOR AND SENSOR UT-1401 Setup Mode ‘Setup Mode’ Mode will shown by pressing key, after Mode display. Range / Values Display Parameter SETUP MODE Range : Values between Password for Setup Mode Parameters Scroll the digit by key, Increase by key.
  • Page 12: Calibration Mode

    DP INDICATOR AND SENSOR UT-1401 Calibration Mode ‘Calibration Mode’ Mode will shown by pressing key, after Mode display. Range / Values Display Parameter CALIBRATION MODE Range : Values between Password for Calibration Mode Parameters Scroll the digit by key, Increase by key.
  • Page 13: Change Password Mode

    DP INDICATOR AND SENSOR UT-1401 Change Password Mode ‘Change Password Mode’ Mode will shown by pressing key, after Mode display. Range / Values Display Parameter CHANGE PASSWORD MODE Range : Values between Password for Change Password Mode. Scroll the digit by key, Increase by key.
  • Page 14: Communication [Modbus Rtu] Protocol

    DATA+ RS-485 BUS Ethernet DATA- CONVERTER www.utplindia.in UNITECH TECHNOCRATS PVT LTD All content are subject to change without notice FACTORY:- 78/1/Z/3-Makarpura G I D C .., due to continuous improvements. +91 7046223333 , 9427301436 N/R Vadasar Bridge. /p-Gayatri emple Doc.