TROUBLESHOOTING
6 TROUBLESHOOTING
Before contacting your local Datalogic office or Datalogic Partner or ARC,
it is suggested to save the device configuration to a *.ddc file by means of
the Genius™ software configuration program and check the device exact
model and serial number.
NOTE
Problem
Power On:
the "Power On" LED is not lit.
On Line Mode:
the Master's "Phase On" LED is not lit
(when external trigger activates).
On Line Mode:
the
Master's
"Phase
correctly lit but nothing happens (no
reading results).
Serial On Line Mode:
the reader is not triggered (no reading
results).
TROUBLESHOOTING GUIDE
Suggestion
•
Is power connected?
•
If using a power adapter (like PG6000), is it
connected to AC source?
•
If using rail power, does rail have power?
•
If using C-BOX 100, does it have power
(check switch and LED)?
Check
25/26-pin connector or to the C-BOX 100
spring clamp connectors.
•
Measure voltage either at pin 13 and
pin 25 (for 25/26-pin connector) or at spring
clamp 1 and (for C-BOX 100).
•
Check carefully if you are referring to the
25/26-pin connector or to the C-BOX 100
spring clamp connectors.
•
Is sensor connected to EXT TRIG/PS input?
•
Is power supplied to photo sensor?
•
Is power supplied to one out of the two EXT
TRIG/PS (NPN output)?
•
Is one out of the two EXT TRIG/PS grounded
(PNP output)?
•
Are the photo sensor LEDs (if any) working
correctly?
•
Is the sensor/reflector system aligned (if
present)?
•
Is the software configuration consistent with
the application condition (operating mode,
On"
LED
is
etc..)?
In
program select the OPERATING MODES
folder and check for related parameters.
•
In
OPERATING MODE folder and check if
serial on line is enabled as "On Line options"
parameter value.
•
Are the Start-Stop string correctly assigned?
•
Is
connected and configured)
if
you
are
the
Genius™
software
the
Genius™
program
the
serial
trigger
6
referring
to
the
configuration
select
the
source
correctly
95