INSTALLATION
The diagram below represents the termination of a DS6400-XXX-010 working as master by
means of the BTK-6000 terminator.
The diagram below represents the termination of a DS6400-XXX-010 working as slave by
means of the BTK-6000 terminator.
The diagram below represents the connection between a DS6400 Fieldbus model, which
always works as master, and a DS6400-XXX-010 working as a slave reader.
Figure 37 – DS6400-XXX-010 Master/Slave Lonworks Connection
Master
VS
9
VS_I/O
6
LON A
7
LON B
8
GND
2
REF_I/O
3
= male connector
= female connector
Figure 35 – DS6400-XXX-010 Master Termination
Slave
LON A
7
LON B
8
= male connector
= female connector
Figure 36 – DS6400-XXX-010 Slave Termination
Fieldbus Master
VS_I/O
4
5
REF_I/O
3
LON A
7
T
LON B
8
CHASSIS
1
VS
9
GND
2
= male connector
= female connector