Error with UniBox connected and analogue heater
Fault code
Faults
Fed
Supply voltage too high
F5d
Temperature sensor error
F12
Communication error on the W-bus
Fe7/Fe8
Flash
Fe9
Signal from switch output SAU1 not plausible
Fea
Faulty feedback signal from heater (ST)
Fec
External control knob sticking
F01 to F0F
Heater error
T5d
UniBox temperature sensor error
T84
Operating voltage too low
Errors relating to a connected heater
Fault code
Faults
F01 to F99
Heater error (analogue)
F01 to FFE
Heater error (W-bus)
H01 to Hxx
MultiControl | SmartControl
Fault description
Supply voltage exceeds 36V.
The temperature from the external sensor
connected to the UniBox cannot be read correctly.
Read/write from/to the internal memory failed.
The UniBox is receiving an implausible signal.
External control knob pressed for longer than
10 seconds.
Please look through the heater documentation.
The temperature from the external sensor
connected to the UniBox cannot be read correctly.
Supply voltage is less than 8V.
Fault description
See workshop manual for heater
Troubleshooting
Check car electrical installation.
Check installation. Contact Webasto service
workshop.
Check installation.
Contact Webasto service workshop.
Check installation. Contact Webasto service
workshop.
Check installation.
Check installation. Contact Webasto service
workshop.
Contact Webasto service workshop.
Check installation. Replace sensor if necessary.
Charge the battery and check car electrical instal-
lation.
Troubleshooting
Contact Webasto service workshop
13