Blood Glucose Monitoring System
GM550
User's Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RIGHTEST GM550 and is the answer not in the manual?

Questions and answers

Chetouane
April 30, 2025

Après insertion de la bandelettes un message s'affiche "code error"

Summary of Contents for BIONIME RIGHTEST GM550

  • Page 1 Blood Glucose Monitoring System BIONIME CORPORATION No. 100, Sec. 2, Daqing St., South Dist., Taichung City 40242, Taiwan Tel: +886 4 2369 2388 GM550 Emergo Europe Fax: +886 4 2261 7586 Prinsessegracht 20 User’s Manual Email: info@bionime.com 2514 AP The Hague http://www.bionime.com...
  • Page 3: Intended Use

    Please forward your warranty card to customer support to activate your warranty coverage. The Blood Glucose Monitoring System GM550 is manufactured and supported by Bionime Corporation. If you have any questions or concerns, please contact your local Bionime Customer Service Representative or send an email to info@bionime.com for further assistance.
  • Page 4 Caution Caution - Before using RIGHTEST Blood Glucose Monitoring System GM550 to test your blood glucose, - The minimum blood sample size required for testing using the RIGHTEST System GM550 is please read all of this information and conduct all of the tests including the Quality Control Test 0.75 μL: ( (p36).
  • Page 5 Limitations Limitations - The RIGHTEST Blood Glucose Monitoring System GM550 is not intended for serum or plasma - DO NOT test on alternative sites (palm, forearm) if you are testing for insulin dose calculations, testing. for Continuous Glucose Monitor (CGM) calibration or hypoglycemia (low blood glucose). - Do not use at altitudes greater than 10,000 feet (3,048 meters).
  • Page 6: Table Of Contents

    Table of Contents Table of Contents About the RIGHTEST System GM550 Quality Control RIGHTEST Blood Glucose Monitoring System GM550 "Lo" and "Hi" Readings RIGHTEST Blood Glucose Meter GM550 About Quality Control Testing RIGHTEST Blood Glucose Test Strip GS550 Other Information Before Testing Performing a Quality Control Test Meter Activation and Battery Change...
  • Page 7: Rightest Blood Glucose Monitoring System Gm550

    RIGHTEST Blood Glucose Monitoring System GM550 RIGHTEST Blood Glucose Monitoring System GM550 Your RIGHTEST Blood Glucose Monitoring System GM550 consists of several items. Please identify each item and make sure you understand how to use them. The items in RIGHTEST Blood Glucose Monitoring System GM550: 1.
  • Page 8: Rightest Blood Glucose Meter Gm550

    RIGHTEST Blood Glucose Meter GM550 RIGHTEST Blood Glucose Meter GM550 Test Strip Port Insert a test strip here until you hear a click. Display Window Battery Cover Shows your test result, messages Slide cover to and related information. change batteries. Meter Battery Main Button ( Meter Label...
  • Page 9 RIGHTEST Blood Glucose Meter GM550 RIGHTEST Blood Glucose Meter GM550 Indicates when to apply the blood Indicates a test result stored in memory sample Indicates a test result will not be Appears after you insert a test strip included in the Average into the meter Indicates the average result Appears when errors occur...
  • Page 10: Rightest Blood Glucose Test Strip Gs550

    RIGHTEST Blood Glucose Test Strip GS550 RIGHTEST Blood Glucose Test Strip GS550 The RIGHTEST Meter GM550 must only be used with RIGHTEST Test Strip GS550 and RIGHTEST Control Solution GC550. The use of other test strips or control solutions may lead to incorrect results. Electrode Contacts Sensing signal output terminals.
  • Page 11: Meter Activation And Battery Change

    Meter Activation and Battery Change Meter Activation and Battery Change Your meter comes with 2 CR2032 3V batteries installed. 2 new batteries provide sufficient power for approximately 1000 tests under normal usage. Press the main button or insert a strip to activate your meter.
  • Page 12: Setting Up Your Meter- Setting The Date, Time, Volume And Test Unit

    Setting Up Your Meter- Setting the Date, Time, Volume and Test Unit Setting Up Your Meter- Setting the Date, Time, Volume and Test Unit You can enter the Settings Mode in two ways: 1. Year Setting When the year blinks, press the Left or Right button to select the 1.
  • Page 13 Setting Up Your Meter- Setting the Date, Time, Volume and Test Unit Setting Up Your Meter- Setting the Date, Time, Volume and Test Unit 4. 12 or 24-hour Format Setting 8. Test Unit Setting When the time format blinks, press the Left or Right When the milligrams per decilitre (mg/dL) or millimoles buttons to select the preferred time format and press per litre (mmol/L) blinks, press the Left or Right button to...
  • Page 14: Turning On / Off The Meter

    Turning On / Off the Meter Handling the RIGHTEST Blood Glucose Test Strip GS550 1. How to turn on the RIGHTEST Meter GM550 Inserting the RIGHTEST Blood Glucose Test Strip GS550: Press the main button or insert a test strip. 1.
  • Page 15: Performing A Blood Glucose Test

    Handling the RIGHTEST Blood Glucose Test Strip GS550 Performing a Blood Glucose Test Removing the RIGHTEST Blood Glucose Test Strip GS550: Depth Adjustable Cap Release Button 1. Hold the test strip as shown. Plunger Lancet Carrier Safety Switch 2. Rotate the test strip counterclockwise and pull up at the same time. Prepare the Lancing Device: Rotate 1.
  • Page 16 Performing a Blood Glucose Test Performing a Blood Glucose Test 7. Rotate the clear top part of the cap to adjust the depth. 11. A blood drop symbol will appear on the screen. Apply a Check the number of lines visible in the View Window. blood sample within 2 minutes.
  • Page 17 Performing a Blood Glucose Test Performing a Blood Glucose Test Lancet and Test Strip Disposal: PRECAUTION 15. Separate the cap from the hub. Press the lancet needle into - Do not apply the blood sample to the strip's sample port until you see " "...
  • Page 18: Alternative Site Testing (Ast)

    Alternative Site Testing (AST) Alternative Site Testing (AST) Alternative site testing-palm or forearm blood sampling CAUTION - Before performing alternative site testing, please replace - Consult your healthcare professional before sampling from your palm or forearm. Palm the depth adjustable cap of your Lancing Device with the - Alternate site testing should be done only during steady-state times (when glucose is clear cap.
  • Page 19: View Window Appearance

    View Window Appearance "Lo" and "Hi" Readings Make sure your blood sample covers the The meter displays results between 10 - 600 mg/dL (0.6 and 33.3 mmol/L). whole area of the View Window to get an If your test result is below 10 mg/dL (0.6 mmol/L), " "...
  • Page 20: About Quality Control Testing

    - RIGHTEST Blood Glucose Meter GM550 - RIGHTEST Blood Glucose Test Strip GS550 NOTE - RIGHTEST Control Solution GC550 RIGHTEST Control Solution GC550 is for the RIGHTEST Blood Glucose Monitoring System GM550. If you want to purchase additional supplies please contact Bionime Customer Service.
  • Page 21: Performing A Quality Control Test

    About Quality Control Testing Performing a Quality Control Test 1. Take a test strip from the vial and close the cap immediately. CAUTION - Each time you open a new bottle of control solution, write the opening date on the label. 2.
  • Page 22: Understanding Control Test Results

    RIGHTEST Blood Glucose Meter to test your blood - Keep the test strip port clean and dry. Clean immediately if the test strip port glucose. Please contact Bionime customer service. is stained or is overly exposed to moisture.
  • Page 23: Maintaining The Products

    Maintaining the Products Maintaining the Products Indirect transmission of Human Immunodeficiency Virus (HIV), Hepatitis B Virus (HBV) and Cleaning and Disinfecting frequency: at least once a week. Hepatitis C Virus (HCV) during the delivery of healthcare services has been increasingly reported. To clean the meter: Persons using blood glucose monitoring systems have been identified as one risk group due to 1.
  • Page 24: Recalling Test Results And Average

    If you have any questions or concerns, please contact your RIGHTEST Blood Glucose 3. View Reading Immediately After Test: If you just finished a test, press the main button to enter Monitoring System GM550 authorized distributor or contact Bionime Customer Service. the memory and review the latest test result.
  • Page 25 Recalling Test Results and Average Recalling Test Results and Average To cancel the exclusion, press and hold the right button until "NO AVG" changes to "AVG", press the main button to confirm. This result is now included in the calculation of the average again. 4.
  • Page 26: Error Messages And Troubleshooting

    Error Messages and Troubleshooting Error Messages and Troubleshooting Temperature Error Battery Error In order to get accurate test results, perform testing between 10 - 40°C (50 - 104°F). 1. The " " symbol blinks when the battery power is low. Please change the meter battery (upper battery) as soon as you can.
  • Page 27 Code Error persists, please contact Bionime Customer Service. Er4 - The blood sample volume is insufficient. Please repeat the test with a new test strip. If error messages persist, please contact Bionime Customer Service.
  • Page 28: Specification

    Memory Capacity 500 blood glucose test results with date and time The RIGHTEST Meter should be working normally after finishing above steps. If not, please contact Bionime Customer Service. Turn off automatically 2 minutes after last user action / Power Saving Press the "...
  • Page 29: Customer Service

    We aim to provide great service to our customers. Please review these instructions to make sure Meter Weight 53.0g ± 5g with batteries you know how to use your product correctly. If you have any questions or encounter any issues with your product, please contact Bionime Customer Service. Monitor LCD display Display Area 46.6 mm x 33 mm...
  • Page 30: Warranty

    Warranty Expected Glucose Values Bionime Corporation warrants that this product will be free from defects in materials and Expected glucose values without diabetes workmanship for five years from the date of purchase. Fasting Blood Glucose This warranty does not apply to the performance of a RIGHTEST Blood Glucose Meter GM550...