BIONIME RIGHTEST GM260 User Manual
Hide thumbs Also See for RIGHTEST GM260:

Advertisement

Quick Links

BIONIME CORPORATION
No. 100, Sec. 2, Daqing St., South Dist.,
Taichung City 40242, Taiwan
Emergo Europe
Tel: +886 4 2369 2388
Prinsessegracht 20
Fax: +886 4 2261 7586
2514 AP The Hague
Email: info@bionime.com
The Netherlands
http://www.bionime.com
Email: EmergoVigilance@ul.com
Made in Taiwan
GM260
0197
Blood Glucose Monitoring System
USER'S MANUAL
GM260

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RIGHTEST GM260 and is the answer not in the manual?

Questions and answers

Summary of Contents for BIONIME RIGHTEST GM260

  • Page 1 Blood Glucose Monitoring System GM260 BIONIME CORPORATION No. 100, Sec. 2, Daqing St., South Dist., Taichung City 40242, Taiwan Emergo Europe Tel: +886 4 2369 2388 Prinsessegracht 20 Fax: +886 4 2261 7586 2514 AP The Hague Email: info@bionime.com USER’S MANUAL The Netherlands http://www.bionime.com...
  • Page 3: Intended Use

    Please forward your warranty card to customer support to activate your warranty coverage. The Blood Glucose Monitoring System GM260 is manufactured and supported by Bionime Corporation. If you have any questions or concerns, please contact your local Bionime Customer Service Representative or send an email to info@bionime.com for further assistance.
  • Page 4 Caution Caution - Before using RIGHTEST Blood Glucose Monitoring System GM260 to test your blood glucose, - The minimum blood sample size required for testing using the RIGHTEST System GM260 is please read all of this information and conduct all of the tests including the Quality Control Test 0.75 μL: ( (p36).
  • Page 5 Limitations Limitations - The RIGHTEST Blood Glucose Monitoring System GM260 is not intended for serum or plasma - Not for screening or diagnosis of diabetes mellitus. testing. - These test strips should not be used with meters to test critically ill patients or neonates. - Do not use at altitudes greater than 10,000 feet (3,048 meters).
  • Page 6: Table Of Contents

    Table of Contents Table of Contents About the RIGHTEST GM260 System Quality Control RIGHTEST Blood Glucose Monitoring System GM260 "Lo" and "Hi" Readings RIGHTEST Blood Glucose Meter GM260 About Quality Control Testing RIGHTEST Blood Glucose Test Strip GS260 Other Information...
  • Page 7: Rightest Blood Glucose Monitoring System Gm260

    RIGHTEST Blood Glucose Monitoring System GM260 RIGHTEST Blood Glucose Monitoring System GM260 Your RIGHTEST Blood Glucose Monitoring System GM260 consists of several items. Please identifyeach item and make sure you understand how to use them.The items in RIGHTEST Blood Glucose Monitoring System GM260: 1.
  • Page 8: Rightest Blood Glucose Meter Gm260

    RIGHTEST Blood Glucose Meter GM260 RIGHTEST Blood Glucose Meter GM260 Test Strip Port Insert a test strip here until you hear a click. Battery Cover Slide cover to change batterry. Display Window Meter Battery Shows your test result, Meter Label messages and related information.
  • Page 9 RIGHTEST Blood Glucose Meter GM260 RIGHTEST Blood Glucose Meter GM260 Indicates a test result stored in memory Tell when to apply the blood sample Indicates a test result, not joining into the Appears after you insert test strip into Average function of this meter meter Indicates with the average result Appears when an error occurs...
  • Page 10: Rightest Blood Glucose Test Strip Gs260

    RIGHTEST Blood Glucose Test Strip GS260 RIGHTEST Blood Glucose Test Strip GS260 The RIGHTEST Meter GM260 must only be used with RIGHTEST Test Strip GS260 and RIGHTEST Control Solution GC550. The use of other test strips or control solutions may lead to incorrect results. Electrode Contacts Sensing signal output terminals.
  • Page 11: Meter Activation And Battery Change

    Meter Activation and Battery Change Meter Activation and Battery Change Your meter comes with 1 CR2032 3V battery installed. 1 new battery provide sufficient power for approximately 1000 tests under normal usage. Press the main button or insert a strip to activate your meter.
  • Page 12: Setting Up Your Meter- Setting The Date, Time, Volume And Test Unit

    Setting Up Your Meter- Setting the Date, Time, Volume and Test Unit Setting Up Your Meter- Setting the Date, Time, Volume and Test Unit You can enter the Settings Mode in two ways: 1. Year Setting When the year blinks, press the Left or Right button to select the current 1.
  • Page 13 Setting Up Your Meter- Setting the Date, Time, Volume and Test Unit Setting Up Your Meter- Setting the Date, Time, Volume and Test Unit 4. 12 or 24-hour Format Setting 8. Test Unit Setting When the time format blinks, press the Left or Right When the milligrams per decilitre (mg/dL) or millimoles per buttons to select the preferred time format and press litre (mmol/L) blinks, press the Left or Right button to select...
  • Page 14: Turning On / Off The Meter

    Turning On / Off the Meter Handling the RIGHTEST Test Strip GS260 1. How to turn on the RIGHTEST Blood Glucose Meter GM260 Inserting the RIGHTEST Blood Glucose Test Strip GS260: Press the Main button or insert a test strip. 1.
  • Page 15: Performing A Blood Glucose Test

    Handling the RIGHTEST Test Strip GS260 Performing a Blood Glucose Test Removing the RIGHTEST Blood Glucose Test Strip GS260: Depth Adjustable Cap Release Button 1. Hold the test strip as shown. Plunger Lancet Carrier Safety Switch Prepare the Lancing Device: 2.
  • Page 16 Performing a Blood Glucose Test Performing a Blood Glucose Test 7. Rotate the clear top part of the cap to adjust the depth. 11. A blood drop symbol will appear on the screen. Apply a Check the number of lines visible in the View Window. blood sample within 2 minutes.
  • Page 17 Performing a Blood Glucose Test Performing a Blood Glucose Test Lancet and Test Strip Disposal: PRECAUTION - Do not apply the blood sample to the strip's sample port until you see " " appear. If 15. Separate the cap from the hub. Press the lancet needle into you apply blood too soon, the meter will perform an internal test and display "...
  • Page 18: Alternative Site Testing (Ast)

    Alternative Site Testing (AST) Alternative Site Testing (AST) Alternative site testing-palm or forearm blood sampling CAUTION - Before performing alternative site testing, please replace - Consult your healthcare professional before sampling from your palm or forearm. Palm the depth adjustable cap of your Lancing Device with the - Alternate site testing should should be done only during steady-state times (when clear cap.
  • Page 19: View Window Appearance

    View Window Appearance "Lo" and "Hi" Readings Make sure your blood sample covers the whole area of the The meter displays results between 10 - 600 mg/dL (0.6 and 33.3 mmol/L). View Window to get an accurate test result. An insufficient If your test result is below 10 mg/dL (0.6 mmol/L), "...
  • Page 20: About Quality Control Testing

    - RIGHTEST Blood Glucose Meter GM260 - RIGHTEST Blood Glucose Test Strip GS260 - RIGHTEST Control Solution GC550 NOTE - RIGHTEST Control Solution GC550 is for the RIGHTEST Blood Glucose Monitoring System GM260. If you want to purchase additional supplies please contact Bionime Customer Service.
  • Page 21: Performing A Quality Control Test

    About Quality Control Testing Performing a Quality Control Test 1. Take a test strip from the vial and close the cap immediately. CAUTION - Each time you open a new bottle of control solution, write the opening date on the label. 2.
  • Page 22: Understanding Control Test Results

    RIGHTEST Blood Glucose Meter to test your by beeps (if volume is turned on). blood glucose. Please contact Bionime customer service. - Do not directly drip the control solution into the test strip's sample port. It is Possible that doing so will contaminate the meter or the control solution.
  • Page 23: Maintaining The Products

    Maintaining the Products Maintaining the Products Indirect transmission of Human Immunodeficiency Virus (HIV), Hepatitis B Virus (HBV) and Cleaning and Disinfecting frequency: at least once a week. Hepatitis C Virus (HCV) during the delivery of healthcare services has been increasingly reported. To clean the meter: Persons using blood glucose monitoring systems have been identified as one risk group due to 1.
  • Page 24: Recalling Test Result And Averages

    If you have any questions or concerns, please contact your RIGHTEST Blood Glucose 3. View Reading Immediately After Test: If you just finished a test, press the main button to enter Monitoring System GM260 authorized distributor or contact Bionime Customer Service. the memory and review the latest test result.
  • Page 25 Recalling Test Results and Average Recalling Test Results and Average PRECAUTION - You have to set the time and date to activate the average function. - The Average function requires that the correct time and date be entered. Test results must be available during the specific time interval.
  • Page 26: Error Messages And Troubleshooting

    Error Messages and Troubleshooting Error Messages and Troubleshooting Sampling Error Temperature Error Please do not apply a blood sample to the sample entry port of the test strip 1. Please test between 10°C (50°F) and 40°C (104°F) in order to obtain accurate before the meter displays "...
  • Page 27 After completing the instructions above, the meter should function normally. Please contact strip. Bionime Customer Service, if the meter is still not working. Er4 - The blood sample volume is insufficient. Please repeat the test with a new test strip.
  • Page 28: Specification

    Specification Specification Measurement Technology Oxidase Electrochemical Sensor Meter Weight 55.0 ± 5g with battery Measuring Range 10 - 600 mg/dL (0.6 - 33.3 mmol/L) Monitor LCD display Test Time 5 seconds Display Area 33.5 mm x 46 mm Memory Capacity 500 blood glucose test results with date and time Meter Storage Conditions -10 - 60°C (14 - 140°F)
  • Page 29: Customer Service

    We aim to provide great service to our customers. Please review these instructions to make sure Bionime Corporation warrants that this product will be free from defects in materials and you know how to use your product correctly. If you have any questions or encounter any issues workmanship for five years from the date of purchase.
  • Page 30: Expected Glucose Values

    Expected Glucose Values Expected glucose values without diabetes Fasting Blood Glucose GLUCOSE LEVEL INDICATION From 70 to 99 mg/dL (3.9 to 5.5 mmol/L) Normal fasting glucose From 100 to 125 mg/dL (5.6 to 6.9 mmol/L) Pre-diabetes (Impaired fasting glucose) 126 mg/dL (7.0 mmol/L) and above on more Diabetes than one testing occasion References...