Blood Glucose Monitoring System
GM700S
BIONIME CORPORATION
No. 100, Sec. 2, Daqing St., South Dist.,
Taichung City 40242, Taiwan
Tel: +886 4 2369 2388
Fax: +886 4 2261 7586
http: //www.bionime.com
E-mail: info@bionime.com
BIONIME GmbH
Tramstrasse 16, 9442 Berneck
USER'S MANUAL
Switzerland
E-mail: info@bionime.ch
GM700S
0197

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the rightest GM700S and is the answer not in the manual?

Questions and answers

shovon biswas
February 11, 2025

auto 000,111,222,333 like that are showing when i insert batteries in my glucometer bionime gm700s . Whats the solution???

User image 67ab991115744
1 comments:
Mr. Anderson
May 14, 2025

On the BIONIME GM700S glucometer, the error codes 000, 111, 222, or 333 displayed when inserting batteries indicate a meter malfunction. To resolve this, remove the batteries, wait 5 minutes, and then reinsert them properly. If the problem persists, contact Customer Service.

This answer is automatically generated

Summary of Contents for BIONIME rightest GM700S

  • Page 1 Blood Glucose Monitoring System GM700S BIONIME CORPORATION No. 100, Sec. 2, Daqing St., South Dist., Taichung City 40242, Taiwan Tel: +886 4 2369 2388 Fax: +886 4 2261 7586 http: //www.bionime.com E-mail: info@bionime.com BIONIME GmbH Tramstrasse 16, 9442 Berneck USER’S MANUAL Switzerland E-mail: info@bionime.ch...
  • Page 3 Venous, arterial, and neonatal blood testing is limited to healthcare professional use only. Rightest Blood Glucose Monitoring System GM700S is manufactured and supported by Bionime Corporation. If you have any questions or concerns, please contact your local Bionime Customer Customer Service or call us at +886-0800-371-688 GMT+08:00, 08:30~17:30.
  • Page 4 Caution Caution - Before using the Rightest Blood Glucose Monitoring System GM700S to test your blood - Avoid contact with dripping or splashing liquids. - The minimum blood sample size to test using the Rightest Blood Glucose Monitoring System glucose, please read all of the instructions and conduct all of the tests including the quality control GM700S is 0.75µL: ( test...
  • Page 5 Table of Contents Table of Contents About the Rightest Blood Glucose Monitoring System GM700S Quality Control Rightest Blood Glucose Monitoring System GM700S ............About Quality Control Testing......................Rightest Blood Glucose Meter GM700S ................Performing a Quality Control Test....................... Rightest Blood Glucose Test Strip GS700 ................
  • Page 6 Rightest Blood Glucose Monitoring System GM700S Rightest Blood Glucose Monitoring System GM700S 3 * Contents GM700S Your Rightest Blood Glucose Monitoring System GM700S consists of several items. Please identify each item, learn its name and how it is used. 4 * Below are the items included in your Rightest Blood Glucose Monitoring System GM700S:...
  • Page 7 Rightest Blood Glucose Meter GM700S Rightest Blood Glucose Meter GM700S Test Strip Port GM700S Display Window Main Button ( Meter Battery Battery Cover Left Button ( Right Button ( 2D barcode with serial number...
  • Page 8 Rightest Blood Glucose Meter GM700S Rightest Blood Glucose Meter GM700S Indicates a test result stored in memory Indicates when to apply the blood sample Indicates a test result not included into the Appears after you insert test strip into meter average results of the meter Appears when an error occurs Indicates the average result...
  • Page 9 Rightest Blood Glucose Test Strip GS700 Rightest Blood Glucose Test Strip GS700 Rightest Blood Glucose Meter G 700S can only be used with Rightest Blood Glucose Test Strips GS700 and Rightest Control Solution GC700. The use of other test strips or control solutions can lead to incorrect results.
  • Page 10 Meter Activation and Battery Change Meter Activation and Battery Change Your Rightest Blood Glucose Meter GM700S comes with one CR2032, 3volt, batteries installed. new batteries will provide power to perform approximately 1000 tests under normal use. Press the main button or insert a strip to activate your meter. 1.
  • Page 11 Setting Up Your Meter - Setting the Date, Time and Volume Setting Up Your Meter - Setting the Date, Time and Volume You can enter the Setting Mode two ways. 1. Year setting With the year format blinking , press the Left or Right button until you see the 1.
  • Page 12 Setting Up Your Meter - Setting the Date, Time and Volume Setting Up Your Meter - Setting the Date, Time and Volume 4. Time format 12/24H selection 7. Volume Setting With the time format blinking, press the Left or Right With the volume blinking, press the Left or Right button to turn the volume on or off.
  • Page 13 Turning On / Off the Meter Handling the Rightest Blood Glucose Test Strip GS700 1. How to turn on the Rightest Blood Glucose Meter GM700S How to handle the Rightest Bl ood Glucose Test Strip GS700 Press the Main button or Insert a test strip. Inserting the Rightest Blood Glucose Test Strip...
  • Page 14 Handling the Rightest Blood Glucose Test Strip GS700 Getting Ready for Testing Removing the Rightest Blood Glucose Test Strip GS700 Before performing a blood glucose test, prepare the items below : 1. Hold the Rightest Blood Glucose Test Strip GS700 as shown.
  • Page 15 Performing a Blood Glucose Test Performing a Blood Glucose Test 1. Hold the depth adjustable cap in one hand and hold the 7. Hold the base in one hand and pull on the plunger with base with the other hand. Bend the cap down. When a the other hand.
  • Page 16 Performing a Blood Glucose Test Performing a Blood Glucose Test 12. A blood drop icon will appear on the display window 16. Pull off the depth adjustable cap. Without touching the and will be accompanied by a beep (if volume is turned used disposable lancet, insert the lancet tip into the on).
  • Page 17 Performing a Blood Glucose Test Setting Markers According to actual life status, you can set meal markers with test result. CAUTION You have to perform meal marker setting immediately after the meter displays the reading of your - Do not apply your blood drop to the sample port on the strip until you see the " "...
  • Page 18 Alternative Site Testing Alternative Site Testing Alternative site testing: palm or forearm blood sampling Palm CAUTION - Test results may vary if blood samples are taken from different sites or under certain Forearm - To perform alternative site testing, install the clear cap for conditions where glucose levels are changing rapidly such as: following a drink, a meal, your Rightest Lancing Device GD500.
  • Page 19 View Window Appearance Understanding Test Results and Messages Make sure your blood sample covers the If your blood glucose result is unusually high or low, or if you question your test results, repeat the whole area of the view window to get an test with a new Rightest Blood Glucose Test Strip GS700.
  • Page 20 Understanding Test Results and Messages About Quality Control Testing Rightest Blood Glucose Meter GM700S displays results between 10 What is a Quality Control Test ? and 600 mg/dL. To ensure proper monitoring function, it is necessary to regularly perform a quality control test. Use one of the Rightest Control Solutions GC700 when testing your...
  • Page 21 About Quality Control Testing About Quality Control Testing When should a Quality Control Test Be Performed ? CAUTION - To ensure that your Rightest Blood Glucose Meter GM700S Rightest Blood Glucose Test - Each time you open a new bottle of control solution, write the expiration date on the label. Strip GS700 are working properly.
  • Page 22 Performing a Quality Control Test Performing a Quality Control Test 1. Take one Rightest Blood Glucose Test Strip GS700 from the vial 9. Tightly replace the cap on the Rightest Control Solution GC700 bottle. CLOSE 10. The control solution result will appear. Compare your Quality Control Test result and close the vial cap immediately.
  • Page 23 Understanding Control Test Results Recalling Test Results Your control solution test results should fall within the control solution range printed on the test strip Rightest Blood Glucose Meter GM700S is able to automatically store a maximum of 500 test vial label. If the results are within the range, the Rightest Blood Glucose Monitoring System results with time and date.
  • Page 24 Recalling Average Test Results Recalling Average Test Results Rightest Blood Glucose Meter GM700S provides several average test results. View the 1- 5. Quick Searching: day, 7-days, 14-days, 30-days, 60-days and 90-days average test results for better blood glucose To view test results in sequential order automatically, enter the Memory Mode. Press the Right or monitoring.
  • Page 25 Error Messages and Troubleshooting Caring for Your Meter Maintenance Temperature Error Keep your meter and test strip free of dust, water or any other liquid. Store the meter in the carrying case when not in use. If your meter is dropped or damaged, perform a quality control test with the 1.
  • Page 26 If one of the above error messages still appears, please contact Bionime strip correctly on p.23 or call Customer Service for support. This error message Customer Service.
  • Page 27 Error Messages and Troubleshooting Limitations Rightest Blood Glucose Monitoring System GM700S is not intended for serum or plasma CAUTION testing. A blood sample should ONLY be applied to the test strip after the test strip has been - Inaccurate test results may be obtained at altitudes greater than 10,000 feet (3048 meters) above inserted correctly and the Meter's screen is showing the image of the test strip and a blood sea level.
  • Page 28 Specification Specification Measurement Technology Hematocrit 10-70% Dehydrogenase Electrochemical Sensor Sample Capillary, Venous, Arterial and Neonatal whole blood One CR2032 Batteries (3 Voltage) Power Supply Approximately 1000 standard tests Minimum Sample Volume 0.75 microliters Battery Life 82 mm x 45 mm x 15.5 mm Measuring Range 10 - 600 mg/dL Meter Dimension...
  • Page 29 Warranty Customer Service Bionime Corporation warrants that this product will be free from defects in materials and We sincerely like to provide complete, considerate services to our customers. Please review all the workmanship for five years from the date of purchase.
  • Page 30 Product complies with In Vitro Diagnostic Medical Device Directive 98/79/EC. (CE0197) Two Hours after meals <140 EC-Rep: Bionime GmbH, Tramstrasse 16, 9442 Berneck / Switzerland References Lancing Device 1) American Diabetes Association: Standard of Medical Care in Diabetes 2011, Diabetes Care, Manufacturer: Bionime Corporation Vol.34, supplement 1, S11-S61, January 2011.