E32 Led Is Lighting After The Cycle Finished; E33 Led Is Lighting - Midea MDK100-CH01B/B05E-EU-C5 Service Manual

Tumble heat pump dryer

Advertisement

5.7 E32 LED is lighting after the cycle finished.

The humidity sensor is blocked

5.8 E33 LED is lighting

The terminals of P3 are loosened
The terminals of front and rear NTC
The terminals of front or rear NTC is
damaged检测技术参数
The wire components are loosened or
Replace the control panel
Y
by fluff
N
Y
N
are loosened
N
N
damaged
N
Y
Clean or replace the humidity sensor
Replace the control panel
Y
Plug in terminals
Y
Plug in terminals
Y
Replace NTC
Y
Plug in or replace the wire assembly