Page 1
OPERATION & SERVICE MANUAL Models: 02-0520C0111 02B0520C0111 02A0520C0111 02C0520C0111 5 Ton (4.5 Metric Ton) Single Stage Jack 04/2014 - Rev. 07 Tronair, Inc. Phone: (419) 866-6301 | 800-426-6301 1 Air Cargo Pkwy East Web: www.tronair.com Swanton, OH 43558 Email: sales@tronair.com...
Page 2
REVISION DATE TEXT AFFECTED 11/2004 6.4.2 added warning and illustrations 04/2007 Modified Parts Lists 09/2012 Major revision 09/2013 Modified Parts List 04/2014 Modified Parts List...
Page 3
Models: 02-0520C0111, 02A0520C0111, 02B0520C0111, 02C0520C0111 5 Ton (4.5 Metric Ton) Single Stage Jack TABLE OF CONTENTS PAGE PRODUCT INFORMATION .............................. 1 NAME OF EQUIPMENT ............................. 1 MODEL NUMBERS ............................1 MANUFACTURED .............................. 1 USAGE ................................1 LIST OF DRAWINGS ............................1 SAFETY INFORMATION ..............................
Page 4
5 Ton (4.5 Metric Ton) Single Stage Jack This product can not be modified without the written approval of Tronair, Inc. Any modifications done without written approval voids all warranties and releases Tronair, Inc., it suppliers, distributors, employees, or financial institutions from any liability from consequences that may occur.
Page 5
Models: 02-0520C0111, 02A0520C0111, 02B0520C0111, 02C0520C0111 5 Ton (4.5 Metric Ton) Single Stage Jack SAFETY INFORMATION (continued) 2.10 NECESSARY PERSONAL PROTECTIVE EQUIPMENT CAUTION! Always wear safety glasses. 2.11 SAFETY GUIDELINES CAUTION! Do not place hands on top of jack near ram locknuts while lowering jack. Pinch points exist between top of jack and threads on ram.
Models: 02-0520C0111, 02A0520C0111, 02B0520C0111, 02C0520C0111 5 Ton (4.5 Metric Ton) Single Stage Jack PACKAGING AND STORAGE (continued) STORAGE SPACE AND HANDLING FACILITIES Minimum Closed Height: 20 in (50.80 cm) Mechanical Extension: 6 in (15.24 cm) Hydraulic Extension: 12 in (30.48cm)
Models: 02-0520C0111, 02A0520C0111, 02B0520C0111, 02C0520C0111 5 Ton (4.5 Metric Ton) Single Stage Jack OPERATION OPERATING PARAMETERS The user shall work in accordance with the Operator Manual At no time shall personnel work under the raised load until it is secured by suitable means, i.e. ram locknut...
Page 8
Models: 02-0520C0111, 02A0520C0111, 02B0520C0111, 02C0520C0111 5 Ton (4.5 Metric Ton) Single Stage Jack OPERATING INSTRUCTIONS (continued) 7.4.1 Rules For Operating: The user shall work in accordance with the Operator Manual At no time shall personnel work under the raised load until it is secured by suitable means, i.e. ram locknut...
Page 9
Models: 02-0520C0111, 02A0520C0111, 02B0520C0111, 02C0520C0111 5 Ton (4.5 Metric Ton) Single Stage Jack 7.4.2 Jack Instructions (continued) Incorrect Pin Placements Washer In Ball Lock In Washer On Top Of Locking Pin Not In Ram Protection Ring Ram Protection Ring Ram Protection Ring...
Models: 02-0520C0111, 02A0520C0111, 02B0520C0111, 02C0520C0111 5 Ton (4.5 Metric Ton) Single Stage Jack 7.4.2 Jack Instructions (continued) If air pump is to be used, be sure shop air needle valve is closed and attach shop air (125 psi/8.6 bars Maximum) to needle valve.
Models: 02-0520C0111, 02A0520C0111, 02B0520C0111, 02C0520C0111 5 Ton (4.5 Metric Ton) Single Stage Jack MAINTENANCE (continued) SERVICING JACK To Disassemble Jack: Remove mounting plate (Item 37) by unscrewing three socket head cap screws (Item 36) Raise ram assembly (Item 39) to the point where it can be lifted from the jack cylinder To Re-assemble Jack: Re-assemble in reverse order of above.
Page 12
GUARANTEES/LIMITATION OF LIABILITY Tronair products are warranted to be free of manufacturing or material defects for a period of one year after shipment to the original customer. This is solely limited to the repair or replacement of defective components. This warranty does not cover the...
Page 13
Models: 02-0520C0111, 02A0520C0111, 02B0520C0111, 02C0520C0111 5 Ton (4.5 Metric Ton) Single Stage Jack Parts List When ordering replacement parts/kits, please specify model, serial number and color of your unit. Item Part Number Description H-1009-01 Assembly, Pump Handle G-1203-1095 Jamnut, ½-20, Elastic...
Page 14
Models: 02-0520C0111, 02A0520C0111, 02B0520C0111, 02C0520C0111 5 Ton (4.5 Metric Ton) Single Stage Jack Parts List When ordering replacement parts/kits, please specify model, serial number and color of your unit. Item Part Number Description TF-1043-03*15.0 Assembly, Hose, 15" long N-2001-08-S-B Elbow, Straight Thread...
Page 15
Models: 02-0520C0111, 02A0520C0111, 02B0520C0111, 02C0520C0111 5 Ton (4.5 Metric Ton) Single Stage Jack Parts List When ordering replacement parts/kits, please specify model, serial number and color of your unit. Item Part Number Description K-1061-04 Kit, Reservoir Replacement; consists of: N-2653-01-S-B Elbow, 90...
Page 16
Models: 02-0520C0111, 02A0520C0111, 02B0520C0111, 02C0520C0111 5 Ton (4.5 Metric Ton) Single Stage Jack Parts List When ordering replacement parts/kits, please specify model, serial number and color of your unit. Item Part Number Description HJ-532-01 Pad, Jack G-1307-0418 Pin, ¼" diameter x 1.8" long...
Page 17
Models: 02-0520C0111, 02A0520C0111, 02B0520C0111, 02C0520C0111 5 Ton (4.5 Metric Ton) Single Stage Jack Parts List - Air Pump Option When ordering replacement parts/kits, please specify model, serial number and color of your unit. Item Part Number Description N-2789-01-S-B Connector, Straight Male, ¼ Hose x SAE #4...
Page 18
Models: 02-0520C0111, 02A0520C0111, 02B0520C0111, 02C0520C0111 5 Ton (4.5 Metric Ton) Single Stage Jack Parts List - Spring Loaded Caster Option Item Part Number Description Jamnut, -18 Elastic G-1203-1105 Flatwasher, Narrow G-1250-1100N Z-3057-02-01 Weldment, Tube H-1128-02 Spring, Compression G-1250-1100W Flatwasher, Wide...
Page 23
APPENDIX II Haskel Air Pump Technical Specifications & Performance Data Drawing 28550...
Page 51
APPENDIX III HC-1948 Hand pump Parts List...
Page 53
1950 psi Hand Pump Parts List With Illustrations 10/2002 – Rev. OR When ordering replacement parts/kits, please specify model, serial number and color of your unit. Tronair, Inc. Phone: (419) 866-6301 | 800-426-6301 1 Air Cargo Pkwy East Web: www.tronair.com Swanton, OH 43558...
Page 55
1950 Hand Pump This product can not be modified without the written approval of Tronair, Inc. Any modifications done without written approval voids all warranties and releases Tronair, Inc., its suppliers, distributors, employees, or financial institutions from any liability from consequences that may occur. Only Tronair OEM replacement parts shall be used.
Page 56
HC-1948 1950 Hand Pump Parts List Illustrations WARNING! Item 10 (H-2683) is a preset relief valve. Do not disassemble this valve. Replacement parts are available as a preset relief valve assembly. 10/2002 | Rev. OR Page | 2...
Page 57
APPENDIX IV Safety Data Sheet MIL-PRF-5606 Hydraulic Fluid...
DECLARATION of CONFORMITY The design, development and manufacture is in accordance with European Community guidelines Tripod Jack 02-0520C0111 02A0520C0111 02-0520C0111 02A0520C0111 Relevant provisions complied with by the machinery: 2006/42/EC Relevant standards complied with by the machinery: EN ISO 12100-1 Identification of person empowered to sign on behalf of the Manufacturer: Quality Assurance Representative Tronair, Inc.
Need help?
Do you have a question about the 02-0520C0111 and is the answer not in the manual?
Questions and answers