10. Services settings
10.1 Heating circuit
Support
Kind of the system
Control method
Weather control
Preset temperature
Decrease of work mode
Decrease of thermostat
OFF by thermostat
Start pump temp.
Min. temperature
Max. temperature
Valve full opening time
Valve input dead zone
Valve dynamic
Valve delay
EWT100 FULL MANUAL
ON or OFF supporting the heating circuit (radiators or underfloor) by the controller.
Selecting the type of heating installation: Radiators system or Underfloor heating.
• Weather control – preset temperature of water circulating in the heating circuit reference is with regard to
indications external temperature sensor. The parameter is invisible when not connected external temperature
sensor. When the external temperature sensor is defective or not connected will automatically change the
Control method on Continous control. • Continous control – maintain is a constant preset temperature of
Heating circuit control depending on external temperature (weather).
The parameters available when choosing a the Control method = Weather control. • Heating curve – choice in
the form of a graph of the heating curve, in range of 10..42ºC, appropriate for the type of building. The higher
heating curve the higher the temperature of the water in the heating circuit. • Curve parallel move – parameter
When Control method = Continous control then the heat source is turned off when you reach the Preset
temperature. When the temperature falls to the heat source is turned on again. This parameter is not available
When the Control method = Continous control, decrease the preset temperature water in circulation during the
Economic mode and Auto mode and during operation time schedule. In other modes temperature water circuit
This parameter can be used only when Room thermostat = ON. Exceeding a preset room temperature causes
decreasing preset temperature of water in the heating circuit by Decrease of thermostat value. Decreasing
the preset temperature takes place upon contact trips the thermostat. Preset temperature of water inside the
heating circuit is not changed if Decrease of thermostat = 0. Parameter disappears when Room thermostat =
Stopping the flow of water in heating circuit by turning off the CH pump when the starting thermostat contact.
Above this parameter followed the inclusion of the circulating pump and the opening of the valve actuator
The minimum preset temperature of water in the heating circuit.
The maximum preset temperature of water in the heating circuit.
Read valve full opening time from a servo housing, e.g. It is usually located on a servo nameplate and within a
Parameter setting defining a temperature dead zone for the heating circuit. The controller controls a servo in
such way that the temperature measured by a circuit sensor is equal to a preset value. Nevertheless in order to
avoid frequent servo movements which can shorten its life, adjustment is carried out only when the measured
water temperature is lower or higher than the mixer dead zone.
The reaction time of the valve actuator to position change. Amplificationof the valve control algorithm.
The mixer valve actuator moved only after this time.
circulating water.
enables to readjust the heating curve.
when Control method = Weather control.
remains constant.
OFF.
circuit regulated.
range of 90 – 180s.
18