8.5   Initial Settings

8.5.1 Feed-in Limitation

The function of the feed-in limitation is to control the amount of power injected in the grid
by the plant. In some situations,this function is also called as Export limitation or Zero
export. The feed-in limitation function requires the using of Smart Energy Meter. Without the
Smart Energy Meter, the feed-in limitation function will be unavailable.

8.5.2 Backup Mode

The backup mode is off by default, the user can set an amount of Reserved Battery SOC
for Off-Grid. It is the minimum battery level in the on-grid state and will be supplied to the
Backup loads in case of grid blackout.

8.5.3 Reactive Power Regulation Mode

The inverter provides a reactive power regulation function. Use the Reactive Power
Regulation Mode parameter to activate this function and select proper regulation mode.