User Manual
Parameter
Reconnect
ing Time
8.10.3 Fault Recovery
Tap Settings > Operation Parameters > Fault Recovery to enter the corresponding
screen, on which you can see the fault recovery records.
8.10.4 Regular Parameters
Tap Settings > Operation Parameters > Regular Parameters to enter the screen, as
shown in the following figure.
After connecting the load to the DO terminals, a relay control signal will be transmitted.
Users can flexibly set the control mode of DO configuration according to individual demand.
NS protection is enabled, and the inverter stops in an emergency.
table 8-7 The control mode of DO configuration
Mode
Off
Load Control Mode
Grounding Detection
8.10.5 Off-grid Parameters
Tap Settings > Operation Parameters > Off-grid Parameters to enter the screen, as
shown in the following figure.
Explanation
The time that the inverter takes to recover
from the fault state to normal state (the
inverter is not running)
figure 8-16 Fault Recovery
figure 8-17 Regular Parameters
Setting description
-
See
8.10.10 Load Control
See
8.10.13 Grounding Detection
8 iSolarCloud App
Default
Range
60s
0s ~ 3600s
115
Need help?