8 iSolarCloud App
step 6 After finishing the settings, tap TUNR ON DEVICE at the upper right corner and the device
will be initialized. The App will send start instructions and the device will start and operate.
step 7 After initialization settings, the App will return automatically to the home page.
- - End
8.5

Initial Settings

8.5.1 Feed-in Limitation

The function of the feed-in limitation is to control the amount of power injected in the grid by
the plant. In some situations,this function is also called as Export limitation or Zero ex-
port. The feed-in limitation function requires the using of Smart Energy Meter. Without the
Smart Energy Meter, the feed-in limitation function will be unavailable.

8.5.2 Backup Mode

The backup mode is off by default, the user can set an amount of Reserved Battery SOC
for Off-Grid. It is the minimum battery level in the on-grid state and will be supplied to the
Backup loads in case of grid blackout.

8.5.3 Reactive Power Regulation Mode

The inverter provides a reactive power regulation function. Use the Reactive Power Regu-
lation Mode parameter to activate this function and select proper regulation mode.
96
figure 8-3 WLAN Local Access
User Manual