Page 2
The qualified service personnel who get KAIXIN written authorization can repair the instrument out of warranty by themselves. But this should be agreed by Xuzhou Kaixin Electronic Instrument Co., Ltd. We will provide circuit diagrams, component part lists or other information to assist service personnel to repair those parts of our equipment that are designated by our company as repairable by service personnel.
Page 3
This user’s manual contains warnings for predictable dangers. Users shall also exercise care at any time to be aware of the dangers unforeseen in this manual. Kaixin shall not be liable for the damages and losses arising out of neglecting to follow the operation instructions herein described.
Page 4
User’s Manual V1.11 Ultrasonic Diagnostic Instrument (Vet) Safety Cautions 1. Warning Symbols and Definitions The following warning symbols are used in this manual to indicate safety level and other important items. Please remember these symbols and understand the meaning as you read this user’s manual. These symbols convey specific meanings as detailed in the table below: Symbols &...
Ultrasonic Diagnostic Instrument (Vet) Chapter Two System Outline 2.1 Structure composition of the instrument V1 ultrasonic diagnostic instrument (Vet) is composed of main unit and probe, etc. 2.2 Components name Figure V1 main unit sketch map Warning : Heat sinks on the both sides of main unit to allow heat release from ultrasound.
User’s Manual V1.11 Ultrasonic Diagnostic Instrument (Vet) 2.4 Function keys description SN. Function keys Real-time status function Freeze status function Mode Selection; Text input, Transfer images/data to the Long press this key to ultrasound workstation, exchange measurement select the diagnostic mode start-end points, etc.
Warning: 1. When instrument works abnormally, do stop working, turn off the power and check the reason, then contacts the KAIXIN Company about it. 2. Turn off power and pull out of the plug from socket after each ultrasonic diagnostic operation.
Ultrasonic Diagnostic Instrument (Vet) Warning: The power adapter, probe, shutter release and power supply cord as described in this section are replaced by operator. But these parts must be provided by KAIXIN or his authorized supplier. 5.1 System installation Please carefully read through and fully understand the use-method before installing the system, and check the goods for its completeness according to the packing list furnished.
User’s Manual V1.11 Ultrasonic Diagnostic Instrument (Vet) Warning: 1. Do not use the probe not provided by our company, otherwise the equipment and the probe will cause damage, and may cause fire in extreme cases. 2. Check the ultrasonic probe and connecting cable after diagnostic operation. Use of defective probe may cause electric shock.
User’s Manual V1.11 Ultrasonic Diagnostic Instrument (Vet) Probe connection schematic 5.2.2 Ultrasonic probe disconnection 1. Turn off the system, pinch the oval position on both sides of the probe cable with one hand and rotate the probe ring counterclockwise with the other hand;...
SUPPLY MAINS. Not to position the EQUIPMENT so that it is difficult to operate the disconnection device. 2. The device should be used only with power adapter provided by Kaixin Company. 3. To avoid damaging power adapter or harming people by unexpected fallen, make sure the power adapter is placed on the leveled desk.
User’s Manual V1.11 Ultrasonic Diagnostic Instrument (Vet) Attention: When the equipment is operated in normal use, the external surface of equipment may be high, but the function operation can be completed in a short time (such as 1s≤t<10s) without affecting the use and harm to the patient and the operator.
User’s Manual V1.11 Ultrasonic Diagnostic Instrument (Vet) Chapter Six Functional Operation 6.1 Startup and Shutdown In shutdown status, press key, machine starts up, power indicator lights. In startup status, hold down key, machine shuts down, power indicator goes out. Please note that when shut down the machine, the time of pressing key is a rather long than normal pressing key.
User’s Manual V1.11 Ultrasonic Diagnostic Instrument (Vet) 6.2.6 Grid setting to select “Preset”; 1. In real-time mode, press key to enter main-menu, press direction keys 2. Press key to enter setting interface; to select “Grid”; 3. Press direction keys to select “00-09”.
User’s Manual V1.11 Ultrasonic Diagnostic Instrument (Vet) 6.2.10 User name setting to select “Preset”; 1. In real-time mode, press key to enter main-menu, press direction keys 2. Press key to enter setting interface; to select “User Name”; 3. Press direction keys key, the cursor is located above “ID”;...
User’s Manual V1.11 Ultrasonic Diagnostic Instrument (Vet) 6.3.5 A Mode In real-time mode, press key to enter or exit A mode. 6.4 Image adjustment and control in B, B/B, B/M and M In real-time mode, you can adjust the total gain, near field gain, far field gain, dynamic range, depth range, frequency, frame correlation, image post-process, edge enhancement, focus quantity, local zoom, left/right reverse, up/down reverse, color, backlight, brightness and contrast, etc.
User’s Manual V1.11 Ultrasonic Diagnostic Instrument (Vet) 6.4.7 Frequency Adjustment (Frequency conversion) In real-time mode, press key to enter main-menu, press direction keys to move cursor to “Freq.” in the display area. Press direction keys to achieve frequency conversion. 6.4.8 Frame Correlation Adjustment...
User’s Manual V1.11 Ultrasonic Diagnostic Instrument (Vet) 6.5 Gain adjustment in A mode In real-time A mode, press key to enter main-menu, press direction keys to move cursor to “Gain” in the display area. Press direction key to increase image gain, press direction key to reduce it.
User’s Manual V1.11 Ultrasonic Diagnostic Instrument (Vet) 2. For the stored image, its file name is automatically named by the image code. 3. When storing images with one-key, you should always pay attention to the remaining frames within the inter memory of main unit to prevent invalid storage. After 420 images have been saved, delete it manually.
User’s Manual V1.11 Ultrasonic Diagnostic Instrument (Vet) 3. Press key to quit saving or reading image status; 4. Press key to return to real-time mode. Note: The specific functions of ultrasound workstation, see “Chapter Ten Ultrasound workstation software instructions”. 6.10.6 Batch images transfer to workstation 1.
User’s Manual V1.11 Ultrasonic Diagnostic Instrument (Vet) 3. Press direction keys to choose “numbers” or “characters” and press key to confirm; key, the screen below shows “Pregnancy, Unpregnancy, Suspected, 4. After inputting ID, press Disease” four kinds of results; at the same time the date and time of inspection automatically shown behind the result;...
User’s Manual V1.11 Ultrasonic Diagnostic Instrument (Vet) 4. Press direction keys to view stored obstetric lists; 5. Press key to exit obstetric list interface and press key to return to real-time status. Explanation: 1. In the obstetric list, the contents of each column respectively: SN, Time, ID, Animal, Formula, G.A and EDC.
User’s Manual V1.11 Ultrasonic Diagnostic Instrument (Vet) Chapter Seven General Measurement 7.1 Distance Measurement 1. In B, B/B mode, freeze desired image, the cursor is located on the “Measure” position of display area; 2. Press key, the measurement methods are showed in the lower left of the screen, press direction to choose “1.Distance”, press...
User’s Manual V1.11 Ultrasonic Diagnostic Instrument (Vet) 2. Press key, the measurement methods are showed in the lower left of the screen, press direction to choose “3.Trace”, press key again, the cursor will show “+”; keys 3. Press direction keys to move the “+” mark to desired position, press key to set the “+”...
User’s Manual V1.11 Ultrasonic Diagnostic Instrument (Vet) Chapter Eight Obstetric Measurement 8.1 Measurement and Calculation items Obstetric tables of the system including: 1.Bovine, 2.Equine, 3.Ovine, 4.Canine, 5.Feline, 6.Goat, 7.Llama, 8. Swine, which is reference for doctor. 8.2 Measurement of Gestational Age (GA) and Estimated Date of Confinement (EDC) Follow the steps below: to move cursor to “OB”...
Page 31
User’s Manual V1.11 Ultrasonic Diagnostic Instrument (Vet) to select “2. Lean”, press 3. Press direction keys key again to confirm, the cursor will show “+”; to select “Weight” (range1~300kg), press 4. Press direction keys key again to confirm; 5. Measure the backfat thickness with distance measurement method, the backfat thickness is displayed in real time in the right area of the screen;...
User’s Manual V1.11 Ultrasonic Diagnostic Instrument (Vet) Chapter Nine Backfat thickness and Lean percentage measurement In A mode, you can measure the swine’s backfat thickness and lean percentage. Figure: A mode interface 9.1 Measurement items Name Abbreviation Unit Backfat thickness...
User’s Manual V1.11 Ultrasonic Diagnostic Instrument (Vet) 3. After the image is automatically frozen, the machine automatically displays four groups’ measurement data and the corresponding waveform. Note: You can get accurate values of the three layers of backfat at the P2 site (the last rib). Many hogs have the thin third layer of backfat.
The images and data stored on the V1 machine are wirelessly transmitted to the ultimate consumers via Wifi, and the user only needs to install the ultrasonic workstation software provided by KAIXIN at the terminal. The machine provides two kinds of ultrasonic workstation software, Android mobile and PC-side ultrasonic workstation software.
4. After the connection is successful, tap the icon “ kx_station_v” to enter ultrasound workstation interface, the wireless signal icon “ ” appears on the lower left corner of the V1 screen, then you can use the mobile ultrasound workstation software.
For example: Local /Internal Storage/kxStation/image/DSC012_20171026135127.bmp 10.3.2.2 Check lists management 1. After the connection between V1 equipment and kx_station_v is successful, the lower left corner of V1 screen shows the wireless signal icon 2. The check lists stored inside of V1 equipment will be transferred to the ultrasound workstation: a.
In this case, you can slide left or right on the list to view. 10.3.2.3 Obstetric lists management 1. After the connection between V1 equipment and kx_station_v is successful, the lower left corner of V1 screen shows the wireless signal icon 2.
User’s Manual V1.11 Ultrasonic Diagnostic Instrument (Vet) A. In the query dialog, the search fields provided are: Check Time, NO, Animal, OB Formula, G.A and EDC. B. Query according to the search field. For example, select the checkbox and enter the exact number: C.
4. After the connection is successful, double-click the icon “ kx_station_v” to enter ultrasound workstation interface, the wireless signal icon “ ” appears on the lower left corner of the V1 screen, then you can use the PC-side ultrasound workstation software.
2. After finish the settings, enter the ultrasound workstation again, the ultrasound workstation interface appears the changed language. Note: KAIXIN ultrasound workstation software supports Chinese and English. Other languages are not support. In the V1 English version, the ultrasound workstation software needs to use the corresponding English language. - 33 -...
User’s Manual V1.11 Ultrasonic Diagnostic Instrument (Vet) Chapter Eleven System Maintenance The system maintenance should be performed by the user and service engineer. Users shall be in full charge of maintenance and operation of the system after purchasing the product.
Page 42
User’s Manual V1.11 Ultrasonic Diagnostic Instrument (Vet) Please follow the instructions about disinfectant concentration and disinfection method, as well as the precautions about disinfectants provided by disinfectant provider. But do not rinse or soak the probe connector or close to connector cable.
User’s Manual V1.11 Ultrasonic Diagnostic Instrument (Vet) Attention: Prohibit using sharp objects to touch the LED screen, and prohibit pressing or squeezing against the LED screen. 6. Clean the control panel, shell Clean the instrument surface with soft, dry cloth or with soft cloth dipped in moderate water cleaning media to remove the blots, and then dry the instrument with soft, dry cloth or with air.
1. The fuse is inside the power adapter. Fuse shall be replaced by qualified service personnel who get KAIXIN approval. Before replacing the fuse, please contact KAIXIN, replace the fuse under the guidance of KAIXIN. 3. Before replacing the fuse, you must disconnect the mains supply.
11.5 Periodic Safety Checks To ensure the system performance and safety, it must be checked after using 1 year. When check the instrument, please consult the International Trade Dept of Kaixin or its dealers, as they need to have professional technology engineers.
User’s Manual V1.11 Ultrasonic Diagnostic Instrument (Vet) Chapter Twelve Storage and Transportation Storage and Transportation 1. If the instrument is stored over 3 months, take out the instrument from the packing case, connect it to power supply for 4 hours, and then disconnect the power and place it in the case again following the direction indicated by arrows on the package.
Page 47
User’s Manual V1.11 Ultrasonic Diagnostic Instrument (Vet) Guidance and Manufacturer’s Declaration Chapter Fourteen This product complies with EMC test standard IEC 60601-1-2. Warning: The use of inappropriate accessory will reduce the performance of the product. Attention: 1. Use of this equipment adjacent to or stacked with other equipment should be avoided because it could result in improper operation.
Page 48
User’s Manual V1.11 Ultrasonic Diagnostic Instrument (Vet) Table 1: Compliance level for electromagnetic emission Emission test Compliance RF emissions Group 1 CISPR 11 RF emissions Class A CISPR 11 Harmonic emissions Class A IEC 61000-3-2 Voltage fluctuations/flicker emissions Complies IEC 61000-3-3 Note: The emissions characteristics of this equipment make it suitable for use in industrial areas and hospitals (CISPR 11 class A).
Page 49
User’s Manual V1.11 Ultrasonic Diagnostic Instrument (Vet) 70%U ) (30%dip in U for 25 (50Hz) cycles 0%U (>95%dip in U for 300 (60Hz) cycles Power frequency (50/60 Hz) magnetic field 30(A/m) IEC 61000-4-8 Note 1: The ISM (industrial, scientific and medical) bands between 0,15 MHz and 80 MHz are 6,765 MHz to 6,795 MHz;...
Need help?
Do you have a question about the V1 and is the answer not in the manual?
Questions and answers