Kaixin KX5600 User Manual

Kaixin KX5600 User Manual

Full digital ultrasonic diagnostic instruments
Table of Contents

Advertisement

KAIXIN
KX5600
User's Manual
Full Digital Ultrasonic Diagnostic
Instruments (Vet)
XUZHOU KAIXIN Electronic Instrument Co., Ltd.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KX5600 and is the answer not in the manual?

Questions and answers

Lawi Rimamsikwe
June 12, 2025

1) How do I connect (and use) a USB gadget to my Kaixin K5600 ultrasound machine 2) Are there some settings I need to do on the machine, and how?

User image 684b2591d2c97

Summary of Contents for Kaixin KX5600

  • Page 1 KAIXIN Full Digital Ultrasonic Diagnostic KX5600 Instruments (Vet) User’s Manual XUZHOU KAIXIN Electronic Instrument Co., Ltd.
  • Page 2 Statement Kaixin has the final explanation right of this user’s manual. Kaixin was considered responsible for the safety, reliability and performance in case of meeting all the following requirements: 1. Assembly, expansion, readjustment, improve and repair are all performed by professionals recognized by Kaixin;...
  • Page 3 This user’s manual contains warnings for predictable dangers. Users shall also exercise care at any time to be aware of the dangers unforeseen in this manual. Kaixin shall not be liable for the damages and losses arising out of neglecting to follow the operation instructions herein described.
  • Page 4 Full Digital Ultrasonic Diagnostic Instruments User’s Manual V1.00 Safety Cautions 1. Warning Symbols and Definitions The following warning symbols are used in this manual to indicate safety level and other important items. Please remember these symbols and understand the meaning as you read this user’s manual. These symbols convey specific meanings as detailed in the table below: Symbols &...
  • Page 5 Full Digital Ultrasonic Diagnostic Instruments User’s Manual V1.00 Attention: Do not place object on the machine. Do not apply external force on the machine. Close the keyboard before moving the machine. Attention: It is prohibited to scratch or squeeze the LCD. Warning: The device should be used only with external AC/DC adapter...
  • Page 6: Table Of Contents

    Full Digital Ultrasonic Diagnostic Instruments User’s Manual V1.00 Contents Chapter One Technical Specifications………………………………………………………1 Chapter Two System Outline …………………………………………………………… 2 2.1 System structure components………………………………………………………… 2 2.2 Components name………………………………………………………………………2 2.3 Parts of the probe……………………………………………………………………… 2 2.4 Rear panel instruction………………………………………………………………… 3 2.5 Function keys instruction……………………………………………………………… 3 Chapter Three System Configuration………………………………………………………6 Chapter Four...
  • Page 7 Full Digital Ultrasonic Diagnostic Instruments User’s Manual V1.00 7.6.12 Image up/down reverse…………………………………………………………… 16 7.6.13 Image left/right reverse…………………………………………………………… 16 7.6.14 Angle/Width change……………………………………………………………… 16 7.6.15 Color selection…………………………………………………………………… 16 7.6.16 Image freeze/unfreeze…………………………………………………………… 16 7.7 Puncture guide……………………………………………………………………… 16 7.8 Lithotripsy positioning line………………………………………………………… 17 7.9 Body mark …………………………………………………………………………… 17 7.10 One-key storage………………………………………………………………………17 7.11 Play back and Measurement…………………...
  • Page 8: Chapter One Technical Specifications

    Full Digital Ultrasonic Diagnostic Instruments User’s Manual V1.00 Chapter One Technical Specifications 1.1 Technical Parameter 1. Gray scale: 256 2. Monitor: 10.4” LCD 3. Adapter rating: 100-240V~, 1.2-0.6A, 50-60Hz 4. Output of Adapter: DC12.8V 3.0A 5. Main device rating: DC12V 3.0A 6.
  • Page 9: Chapter Two System Outline

    Full Digital Ultrasonic Diagnostic Instruments User’s Manual V1.00 Chapter Two System Outline 2.1 System structure components KX5600 full digital ultrasonic diagnostic instruments (Vet) are composed of main unit, probe etc. 2.2 Components name Probe Display Main unit Keyboard Fig. KX5600 Main unit sketch map 2.3 Parts of the probe (Take 6.5MHz animal transrectal linear array probe for example)
  • Page 10: Rear Panel Instruction

    Full Digital Ultrasonic Diagnostic Instruments User’s Manual V1.00 2.4 Rear panel instruction USB port USB port Network interface Color SVGA output Color SVGA Out Video output interface Foot switch Fig. Real panel A sketch map Power input interface Fig. Real panel B sketch map 2.5 Function keys instruction SN Key symbol Key name Key function...
  • Page 11 Full Digital Ultrasonic Diagnostic Instruments User’s Manual V1.00 ·Access to new patient module; New patient ·Input the information and data for new patient; ·In annotation status, press the key to enter the function of arrow mark; Arrow ·Now, through rotate 【Gain】 or 【 Function】 knob to adjust the direction of arrow mark.
  • Page 12 Full Digital Ultrasonic Diagnostic Instruments User’s Manual V1.00 Obstetric Press the key to enter/exit obstetric measurement menu; ·Press key to perform the confirm function; ·Press the key to increase the values of parameters; Back Press the key to decrease the values of parameters; Freeze Press the key to freeze or unfreeze the image;...
  • Page 13: Chapter Three System Configuration

    Full Digital Ultrasonic Diagnostic Instruments User’s Manual V1.00 Chapter Three System Configuration 3.1 Typical configuration 1. Main unit 1 unit 2. 6.5MHz animal transrectal linear array probe 1 PC 3. Power adapter 1 PC 3.2 Optional parts 1. 3.5 MHz convex array probe 2.
  • Page 14: Chapter Five System Installation And Check

    Warning: 1. When instrument works abnormally, do stop working, turn off the power and check the reason, then contacts the KAIXIN Company about it. 2. Turn off power and pull out of the plug from socket after each ultrasonic diagnostic operation.
  • Page 15: System Placement

    The probe bracket should be mounted behind the main unit. 5.3 Ultrasonic probe installation Warning: 1. The Kaixin ultrasonic probe shall be connected to the dedicated Kaixin ultrasonic system only. Select proper probe according to the relevant instructions of ultrasonic diagnostic system.
  • Page 16: Install/Remove The Battery

    1. Adapter has no switch. The isolation of the system with the MAINS used to unplug the adapter as the intended isolation means. 2. The equipment should be used only with adapter provided by Kaixin Company. 3. To avoid damaging power adapter or harming people by unexpected fallen, make sure the power adapter is placed on the leveled desk.
  • Page 17: Ultrasonic Probe Check Before And After Operation

    Full Digital Ultrasonic Diagnostic Instruments User’s Manual V1.00 5.8 Ultrasonic probe check before and after operation Before and after ultrasonic diagnosis to check if there are any exceptionally on the surface of the probe or cable jacket, such as peeling, cracks, bulge, or if the acoustic lens is reliable, cleaned or disinfected.
  • Page 18: Chapter Six Preset

    Full Digital Ultrasonic Diagnostic Instruments User’s Manual V1.00 Chapter Six Preset 6.1 System preset Press key on the keyboard, “System Preset” menu will be displayed on the screen. Fig. System preset menu 6.1.1 Normal Move the cursor to the “Normal”, press『Set』key, the cursor is in the input box of hospital name. ...
  • Page 19: Formula Preset

     Use the following IP address Set the IP address of full digital ultrasonic diagnostic instrument: IP address: IP address of KX5600 instrument;  LAN Server Set Set LAN server’s network properties: IP address: IP address of LAN server (that is IP address of PC installing print program);...
  • Page 20: Password Preset

    5. Move the cursor to the「OK」, press『Set』key to exit the password preset interface. Warning: Business personnel or service personnel setting the password, be sure to remember the set password, make notes! If you forget password, consult Kaixin Company. - 13 -...
  • Page 21: Chapter Seven Functional Operation

    Full Digital Ultrasonic Diagnostic Instruments User’s Manual V1.00 Chapter Seven Functional Operation 7.1 Startup and Shutdown Press the button on the bottom of screen, turn on the machine. If you want to turn off the machine, please press the button again, then pull out mains plug from the supply mains.
  • Page 22: Image Quality Adjustment And Image Control

    Full Digital Ultrasonic Diagnostic Instruments User’s Manual V1.00 2. Press freeze key to freeze or unfreeze the current image; 3. In real-time M mode, press key to exit M mode. 7.6 Image quality adjustment and image control 7.6.1 Image brightness adjustment Proper brightness of the LCD is essential for a quality image.
  • Page 23: Image Post-Process Adjustment

    Full Digital Ultrasonic Diagnostic Instruments User’s Manual V1.00 Menu】; 2. Press 『 Set』 or 『 Back』 key to realize compression curve processing. The compression curve falls into eight levels, which are 0-7 and displayed in the〖Comp Curve〗of the left menu. Note: If use 3.5 MHz probe, it is recommended to choose 5 or 6;...
  • Page 24: Lithotripsy Positioning Line

    Full Digital Ultrasonic Diagnostic Instruments User’s Manual V1.00 Press key to switch puncture guide line, press direction keys to change the angle of the second puncture guide line, press direction keys to change the start position of the second puncture guide line. Press key to exit the puncture guide status.
  • Page 25: Annotation

    Full Digital Ultrasonic Diagnostic Instruments User’s Manual V1.00 automatic playback status. Press key to exit playback status. Press key unfreeze and exit playback status.  Playback measurement In manual playback status and choose measured image, press key to exit playback status and perform measurement.
  • Page 26: Chapter Eight Image Management

    Full Digital Ultrasonic Diagnostic Instruments User’s Manual V1.00 Chapter Eight Image management The system stores and manages the frozen images or reports in BMP format. The image management interface is divided into file management region, file display region and function button region. The work interface is as follows: 8.1 Enter/exit image management 1.
  • Page 27: Chapter Nine Print And Transfer Files

    1. This instrument and the PC connected to the same local area network; 2. Set the network properties of this instrument: IP address: IP address of KX5600 instrument; 3. Set the IP address of printer connected to this instrument (LAN Server Set): IP address: IP address of PC installing printer;...
  • Page 28: Usb Print

    Full Digital Ultrasonic Diagnostic Instruments User’s Manual V1.00 9.1.2 USB Print 1. Insert U disk into the USB port at the back of main unit; 2. When U disk connected to this instrument, the status bar at the bottom right of the screen will pop up USB icon;...
  • Page 29: Chapter Ten B General Measurement

    Full Digital Ultrasonic Diagnostic Instruments User’s Manual V1.00 Chapter Ten B General Measurement Attention: The accuracy of software measurement: distance measurement ≤0.1mm; area measurement ≤ 0.1mm ; volume measurement ≤ 0.1mm ; heart rate measurement ≤ 1bpm; time measurement ≤ 1ms. Due to differences in images obtained by each user in different times, the actual object for the accuracy of the measurement may be greater than the above-mentioned values.
  • Page 30: Volume Measurement

    Full Digital Ultrasonic Diagnostic Instruments User’s Manual V1.00 『Set』key, make the “+”position as the starting point to be measured; 4. Operate the trackball or the direction keys to move the “+” mark to the end point of the measurement, at the same time it appears a trace between two measurement marks along the direction of operation.
  • Page 31: Angle Measurement

    Full Digital Ultrasonic Diagnostic Instruments User’s Manual V1.00 Where, A is the major axis of the ellipse; B is the minor axis of the ellipse. 1. Choose a valuable image in B, B/B or 4B mode; 2. Press『Measure』key, the cursor will show “+”, move the cursor to the〖2-Axis〗of〖Volume〗 submenu of【B Meas】, press『Set』key;...
  • Page 32: Profile Measurement

    Full Digital Ultrasonic Diagnostic Instruments User’s Manual V1.00 of【B Meas】, press『Set』key; 3. Operate the trackball or the direction keys to move the “+” mark to the desired position, press 『Set』key, make the “+”position as the starting point to be measured; 4.
  • Page 33 Full Digital Ultrasonic Diagnostic Instruments User’s Manual V1.00 of〖% Stenosis〗of【B Meas】, press『Set』key; 3. Measure the distance D1 at the non-stenosis position, the method is the same as “Distance” measurement; 4. Measure the distance D2 at the stenosis position, the method is the same as “Distance” measurement.
  • Page 34: Chapter Eleven B Obstetric Measurement

    Full Digital Ultrasonic Diagnostic Instruments User’s Manual V1.00 Chapter Eleven B Obstetric Measurement Obstetric calculation is usually done in B image mode. In B, B/B, 4B or B/M mode, press『OB』key to open “B-OB Meas” menu. B obstetric measurement menu is shown as below: Fig.
  • Page 35: Chapter Twelve M General Measurement

    Full Digital Ultrasonic Diagnostic Instruments User’s Manual V1.00 Chapter Twelve M General Measurement 】 In B/M, M mode, press『Measure』key to enter【M Meas menu. M general measurement menu is shown as follows: M Meas Depth Slope Heart Rate Time Fig. M general measurement menu 12.1 Depth measurement Function: Measure the distance between the vertical two points in M image.
  • Page 36: Time Measurement

    Full Digital Ultrasonic Diagnostic Instruments User’s Manual V1.00 4. Press『Set』key to finish the measurement; 5. Repeat steps 2~4 to measure next time; 6. Press『Measure』key to exit the measurement. 12.4 Time measurement Function: Measure the time interval between two points in M image. Measurement method: 1.
  • Page 37: Chapter Thirteen System Maintenance

    2. Clean the probe with sterile water to remove the residual chemicals after disinfection, because the residual chemicals may be harmful for humans. 3. Kaixin Company will not make any guarantee for the efficacy of disinfector. Please contact the appropriate manufacturer for details.
  • Page 38 Full Digital Ultrasonic Diagnostic Instruments User’s Manual V1.00 Glutaraldehyde-based disinfectant: Chemical Name Reagent Name Step Please refer to the Cidex Glutaraldehyde Glutaraldehyde (2.4%) instructions of the solution disinfectant for details. Non-glutaraldehyde-based disinfectant: Chemical Name Reagent Name Step Please refer to the Phthalaldehyde solution Cidex OPA instructions of the solution...
  • Page 39 Full Digital Ultrasonic Diagnostic Instruments User’s Manual V1.00 window, such as scuffing, cracks, peeling, and bulge. 4. Clean the probe cable and its connector (1) Clean the probe cable and its connector with soft, dry cloth. (2) In case of die-hard blots, clean with soft cloth dipped in moderate detergent and then air-dry 5.
  • Page 40: Replace The Fuse

    13.3 Use and maintenance for the rechargeable battery  The battery use for main unit 1. Only use charger and battery pack (model HYLB-1614) provided by KaiXin Company. 2. The output port of adapter plugs into the input port of “charger” to charge (see the charge sketch map for main unit battery).
  • Page 41 Full Digital Ultrasonic Diagnostic Instruments User’s Manual V1.00 Attention: 1. Do not throw the battery into water or be wet, which will lead to the battery leakage, explosion or fire; Attention: Battery charger shall meet the requirements of IEC60601-1 standard. 2.
  • Page 42: Troubleshooting

    13.5 Periodic Safety Checks To ensure the system performance and safety, it must be checked after using 1 year. When check the instrument, please consult the International Trade Dept of Kaixin or its dealers, as they need to have professional technology engineers.
  • Page 43: System Block Diagram

    Full Digital Ultrasonic Diagnostic Instruments User’s Manual V1.00 Test the patient leakage current according to IEC 60601-1: Limit: for a.c.: 100μA (B), for d.c.:  10μA (B). Test the patient leakage current under single fault condition with mains voltage on the applied ...
  • Page 44: Chapter Fourteen

    Full Digital Ultrasonic Diagnostic Instruments User’s Manual V1.00 Chapter Fourteen Storage and Transportation Storage and Transportation 1. If the instrument is stored over 3 months, take out the instrument from the packing case, connect it to power supply for 4 hours, and then disconnect the power and place it in the case again following the direction indicated by arrows on the package.
  • Page 45 Full Digital Ultrasonic Diagnostic Instruments User’s Manual V1.00 Chapter Guidance and Manufacturer’s Declaration Sixteen This product complies with EMC test standard EN60601-1-2 Warning: The use of inappropriate accessory will reduce the performance of the product. Attention: 1. The use of the accessory, transducer or cable other than those specified may result in increased emissions or decreased immunity of the system.
  • Page 46 Full Digital Ultrasonic Diagnostic Instruments User’s Manual V1.00 Table 2 - Guidance and manufacturer’s declaration—electromagnetic immunity This equipment is intended for use in the electromagnetic environment specified below. Customer or user shall assure that it is used in such an environment. Immunity test IEC60601 test Compliance level...
  • Page 47 Full Digital Ultrasonic Diagnostic Instruments User’s Manual V1.00 Table 3 - Guidance and manufacturer’s declaration—electromagnetic immunity This equipment is intended for use in the electromagnetic environment specified below. Customer or user shall assure that it is used in such an environment. Immunity test IEC60601 test Compliance...
  • Page 48 Full Digital Ultrasonic Diagnostic Instruments User’s Manual V1.00 Table 4 - Recommended separation distance between portable and mobile RF communications equipment and this equipment This equipment is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the equipment can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and this equipment as recommended below, according to the maximum output power of the communications equipment.
  • Page 49 KAIXIN ELECTRONIC XUZHOU KAIXIN ELECTRONIC INSTRUMENT CO., LTD. Kaixin Mansion, C-01. Economic Development Zone, Xuzhou, Jiangsu, China Post Code: 221004 Tel: +86-516-87732932/87733758 Fax: +86-516-87732932/87792848 Website: http://www.kxele.com E-mail: gm01@kxele.com Information contained in this manual is subject to change without further notice.

Table of Contents