Installation, Operation and Maintenance APP 11 - 13 / APP S 11 - 13

5.1 Important dimensions

Physical dimensions and connections of the
pump unit are described in appendix 1, Data
sheet.

5.2 Cleanliness

It is very important that the tubes and pipes are
completely clean: no dirt, chips or burrs are
allowed. Flush all piping before connecting the
high-pressure pump to ensure the system is
clean. Internal surfaces of the piping must not be
corroded. If dirt or rust is not removed, the pump
and the valves can be damaged. In worst case
the pump can be damaged beyond repair!

5.3 Fluid temperature

Before start-up, the uid and pump housing
temperature must be within the speci ed
temperature range listed see appendix 1, Data
sheet.
Schematic 1: Recommended system design
Media filter
PI
PI
Feed
Fresh water
permeat flush

5.4 Electrical data

Check voltage, current frequency and rated
power on the electric motor and VFD settings on
the name plate placed on both the motor and
the VFD.

5.5 Local regulations

Commissioning must always be done in
accordance with valid regulations and local
standards.
PI
PI
PT
PI
Permeate
PI
Brine