Endress+Hauser Proline Promass F 200 FOUNDATION Fieldbus Operating Instructions Manual page 146

Coriolis flowmeter
Table of Contents

Advertisement

Appendix
Relative
Index
13
TRDASUP_CollectionDirectory
14
TRDASUP_BlockErrDesc_1
15
TRDASUP_STD_UserLevel_1
16
TRDASUP_STD_LockingState_1
17
TRDASUP_FLOW_InstallationDirection_1
18
TRDASUP_CFM_ZeroPointAdjustControl_1
19
TRDASUP_CFM_ZeroPointAdjustProgress_1
20
TRDASUP_CFM_ZeroPointAdjustState_1
21
TRDASUP_PFS_OperatingMode_1
22
TRDASUP_PFS_PulseInputSelector_1
23
TRDASUP_PFS_PulseValue_1
24
TRDASUP_PFS_PulseWidth_1
25
TRDASUP_PFS_PulseMeasuringMode_1
26
TRDASUP_PFS_PulseFailsafeMode_1
27
TRDASUP_PFS_PulseOutValue_1
28
TRDASUP_PFS_FrequencyInputSelector_1
29
TRDASUP_PFS_FrequencyMinFrequency_1
30
TRDASUP_PFS_FrequencyMaxFrequency_1
31
TRDASUP_PFS_FrequencyMinValue_1
32
TRDASUP_PFS_FrequencyMaxValue_1
33
TRDASUP_PFS_FrequencyMeasuringMode_1
34
TRDASUP_PFS_FrequencyDamping_1
35
TRDASUP_PFS_OverallSignalDamping_1
36
TRDASUP_PFS_FrequencyFailsafeMode_1
37
TRDASUP_PFS_FrequencyFailsafeValue_1
38
TRDASUP_PFS_FrequencyOutValue_1
39
TRDASUP_PFS_StateMode_1
40
TRDASUP_PFS_MessageSelector_1
41
TRDASUP_PFS_LimitCheckSelector_1
42
TRDASUP_PFS_StateSwitchOnValue_1
43
TRDASUP_PFS_StateSwitchOffValue_1
44
TRDASUP_PFS_DirectionCheckSelector_1
45
TRDASUP_PFS_StateValueSelector_1
146
Name
Collection Directory
Locking status
adjustment control
Adjustment in
Zeropoint adjust
Operating mode
Assign pulse output
Value per pulse
Measuring mode
Assign frequency
Minimum frequency
frequency value
Measuring value at
minimum frequency
Measuring value at
Measuring mode
Damping output
Response time
Failure frequency
Output frequency
Assign diagnostic
Switch-on value
Switch-off value
direction check
Proline Promass F 200 FOUNDATION Fieldbus
Label
Data type
UINT32
Block error
BIT_ENUM32
description
Access status
ENUM16
tooling
BIT_ENUM16
Installation
ENUM16
direction
Zero point
ENUM16
UINT8
progress
ENUM16
state
ENUM16
ENUM16
FLOAT
Pulse width
FLOAT
ENUM16
Failure mode
ENUM16
Pulse output
FLOAT
ENUM16
output
FLOAT
value
Maximum
FLOAT
FLOAT
FLOAT
maximum
frequency
ENUM16
FLOAT
FLOAT
Failure mode
ENUM16
FLOAT
FLOAT
Switch output
ENUM16
function
ENUM16
behavior
Assign limit
ENUM16
FLOAT
FLOAT
Assign flow
ENUM16
Assign status
ENUM16
Storage
Size
MODE_BLK Writability
Class
(Bytes)
Static
4
Dynamic
4
Static
2
Dynamic
2
Static
2
AUTO
Static
2
AUTO
Static
1
Static
2
Static
2
AUTO
Static
2
AUTO
Static
4
AUTO
Static
4
AUTO
Static
2
AUTO
Static
2
AUTO
Dynamic
4
Static
2
AUTO
Static
4
AUTO
Static
4
AUTO
Static
4
AUTO
Static
4
AUTO
Static
2
AUTO
Static
4
AUTO
Static
4
Static
2
AUTO
Static
4
AUTO
Dynamic
4
Static
2
AUTO
Static
2
AUTO
Static
2
AUTO
Static
4
AUTO
Static
4
AUTO
Static
2
AUTO
Static
2
AUTO
Endress+Hauser
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Proline Promass F 200 FOUNDATION Fieldbus and is the answer not in the manual?

Table of Contents