3.6. Repeat Test
14
3.6
Repeat Test
① The repeat test is possible for up to 3 absolute position values.
② Delay time and repeat count can be set every repeat.
* Delay Time : Stand-by time until each motion is ended and then next motion is started. The unit
is [msec].
* Repeat : To define the motion loop count. If this is set to '0', the test is endlessly repeated.
③ Operation status and repeat count are displayed.
* Cycle Time : displays the time until repeat test is completely finished.
* Repeat Count : increases whenever one motion loop is finished.
④ When the user clicks 'Repeat' button while the machine is operating, the cycle in service ends
and the machine stops operating.
regardless of the cycle.
①
②
Click 'Stop' or 'E-Stop' button, and the machine will stop
www.fastech.co.kr
③
④