KaVo 1.011.6771 Instructions For Use Manual
Hide thumbs Also See for 1.011.6771:

Advertisement

Quick Links

Instructions for use
SMARTmatic S80 K – 1.011.6771

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 1.011.6771 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for KaVo 1.011.6771

  • Page 1 Instructions for use SMARTmatic S80 K – 1.011.6771...
  • Page 2 Distributed by: Manufacturer: KaVo Dental GmbH KaVo Dental GmbH Bismarckring 39 Bismarckring 39 88400 Biberach 88400 Biberach Germany Germany Phone +49 7351 56-0 www.kavo.com Fax +49 7351 56-1488...
  • Page 3: Table Of Contents

    Instructions for use SMARTmatic S80 K – 1.011.6771 Table of contents Table of contents 1 User instructions....................... 2 Safety ..........................2.1 Infection hazard......................7 2.2 Improper use ....................... 7 2.3 Technical condition......................8 2.4 Accessories and combination with other equipment ............8 2.5 Qualification of personnel....................
  • Page 4: User Instructions

    SMARTmatic is a registered trademark of KaVo Dental GmbH. All other trademarks are property of their respective owners. KaVo Original Factory Repair In the event of a repair, please ship your product to the KaVo Original Factory Repair using www.kavobox.com. KaVo Technical service...
  • Page 5 Instructions for use SMARTmatic S80 K – 1.011.6771 1 User instructions Serial number UDI symbol Manufacturer Note: Please note accompanying documents Follow the electronic instructions for use HIBC Code CE mark for medical devices EAC conformity mark (Eurasian Conformity) UA Mark of conformity UA.TR.099...
  • Page 6 Instructions for use SMARTmatic S80 K – 1.011.6771 1 User instructions WARNING In cases which – if not prevented – can lead to death or severe injury. CAUTION In cases which – if not prevented – can lead to minor or moderate injury.
  • Page 7: Safety

    Instructions for use SMARTmatic S80 K – 1.011.6771 2 Safety | 2.1 Infection hazard 2 Safety NOTE All serious events occurring in relation to the product must be reported to the manufacturer and the competent authority of the member state, in which the user and/or patient resides.
  • Page 8: Technical Condition

    2 Safety | 2.3 Technical condition 2.3 Technical condition A damaged product or damaged or NOT KaVo original components could injure patients, users or third parties. 4 Only operate devices or components if they show no signs of damage on the outside.
  • Page 9: Service And Repair

    Define the service interval depending on the frequency of use. As a result of the use of NON-KaVo original spare parts during the repair, parts such as covers may become undone and injure the patient, user or other people.
  • Page 10: Product Description

    Instructions for use SMARTmatic S80 K – 1.011.6771 3 Product description | 3.1 Intended use 3 Product description SMARTmatic S80 K (Mat. no. 1.011.6771) 3.1 Intended use Indications for use: This medical device is: ▪ Intended for dental treatment only. All other types of use of or modifications to the product are not permitted and can be hazardous.
  • Page 11: Transportation And Storage Conditions

    Instructions for use SMARTmatic S80 K – 1.011.6771 3 Product description | 3.3 Transportation and storage conditions 3.3 Transportation and storage conditions CAUTION Startup after refrigerated storage. Malfunction. 4 Prior to startup, strongly refrigerated products must be allowed to warm up to a temperature of 20 °C to 25 °C (68 °F to 77 °F).
  • Page 12: Startup And Shut Down

    Dispose of and recycle the packaging appropriately in accordance with current packaging law, employing waste management / recycling companies. Comply with the comprehensive return system. KaVo has had its packaging licensed for this purpose. Please comply with the regional public waste-disposal system.
  • Page 13: Operation

    Instructions for use SMARTmatic S80 K – 1.011.6771 5 Operation | 5.1 Attaching the medical device 5 Operation WARNING Rotating dental tool. Cuts, infection and burn injury. 4 Never push the press-button while the dental tool is rotating. 4 Do not touch the dental tool while it is rotating.
  • Page 14: Inserting The Dental Bur

    CAUTION Dental tool with damaged, worn or deformed shafts. A damaged product or damaged or NOT KaVo original components can injure patients, users or third parties. Injury hazard, dental tool may fall out during treatment. 4 Never use dental tools with damaged, worn or deformed shafts.
  • Page 15: Removing The Dental Bur

    Instructions for use SMARTmatic S80 K – 1.011.6771 5 Operation | 5.4 Removing the dental bur CAUTION Dental tool with damaged, worn or deformed shafts. Material damage to the chuck system, dental tool is difficult or impossible to re- move from the chuck system.
  • Page 16: Checking For Malfunctions And Troubleshooting

    Malfunction or complete failure. 4 Do not use Vaseline or other grease or oil. 4 Spray a lint-free cloth with KaVo Spray and apply it to the O-rings on the coupling. 4 Press the O-ring between your fingers to form a loop.
  • Page 17 Instructions for use SMARTmatic S80 K – 1.011.6771 6 Checking for malfunctions and troubleshooting | 6.2 Troubleshooting 4 Spray a lint-free cloth with KaVo Spray, apply it to the new O-rings and in- sert them in the recesses. 17 / 28...
  • Page 18: Reprocessing Steps In Accordance With Iso 17664-1 / Iso 17664-2

    Malfunction and material damage. 4 Reprocess in a washer disinfector or by hand only. KaVo recommends the following products based on the compatibility of the ma- terials. The microbiological efficacy must be ensured by the disinfectant manu- facturer and proven by an expert opinion.
  • Page 19: Manual Reprocessing

    Instructions for use SMARTmatic S80 K – 1.011.6771 7 Reprocessing steps in accordance with ISO 17664-1 / ISO 17664-2 | 7.2 Manual reprocessing 7.2 Manual reprocessing WARNING Incomplete disinfection. Patients, users or third parties could be infected by contaminated medical devices.
  • Page 20: Manual Drying

    7.2.3 Manual drying Use KaVo DRYspray for subsequent drying of the air, water and gear unit ducts. 4 Cover the medical device with the KaVo Cleanpac bag, and place it on the corresponding care adapter. 4 Hold the can vertically.
  • Page 21: Pre-Cleaning

    NOTE Please comply with the instructions for use of the washer disinfector. 4 In order not to affect the KaVo medical device, make sure that the product is dry on the inside and outside after completion of the cycle. 4 Remove any residual liquids with KaVoDRYspray.
  • Page 22: Servicing With Kavo Spray

    30 minutes of operation. 4 Remove the dental tool from the medical device. 4 Cover the medical device with the KaVo Cleanpac bag, and place it on the corresponding care adapter. 4 Press the spray key for 1 to 2 seconds.
  • Page 23: Packaging

    Instructions for use SMARTmatic S80 K – 1.011.6771 7 Reprocessing steps in accordance with ISO 17664-1 / ISO 17664-2 | 7.5 Packaging NOTE End the chuck service mode. Option 1: Place the dental handpieces in the QUATTROcare PLUS 2124 A, close the front flap and start the service procedure.
  • Page 24 Instructions for use SMARTmatic S80 K – 1.011.6771 7 Reprocessing steps in accordance with ISO 17664-1 / ISO 17664-2 | 7.7 Storage NOTE Comply with the expiry date of the sterilised items. 24 / 28...
  • Page 25: Optional Aids And Consumables

    Instructions for use SMARTmatic S80 K – 1.011.6771 8 Optional aids and consumables 8 Optional aids and consumables Available from specialised dental dealers. Material summary Mat.No. INTRA Instrument stand 3.005.5204 Cleanpac 10 units 0.411.9691 Cellulose pad 100 units 0.411.9862 KaVo CLEANspray 2110 P 1.007.0579...
  • Page 26: Terms And Conditions Of Warranty

    12 months from the date of the invoice, subject to the following conditions: In case of justified complaints KaVo shall honour its warranty with a free re- placement or repair. Other claims of any kind whatsoever, in particular with re- spect to compensation, are excluded.

This manual is also suitable for:

Smartmatic s80 k

Table of Contents