22. The applicable operating temperature range for this unit is 10-35˚C. 23. Do not operate your dehumidifier in a wet room such as a bathroom or laundry room. 24. Spaces where refrigerant pipes shall be compliance with national gas regulations. www.danvex.com...
TRANSPORTATION, MARKING AND STORAGE 1. Transport of equipment containing flammable refrigerants Compliance with the transport regulations 2. Marking of equipment using signs 1. Compliance with local regulations 2. Disposal of equipment using flammable refrigerants Compliance with national regulations 3. Storage of equipment/appliances 4.
Press the key to set the relative humidity you need. (From RH30%, 35%, 40%, 45%, …90%, comfort mode [AU], to continuous dehumidification [CO]. When ambient humidity is lower than setting humidity by 3%, compressor will stop automatically, and return working until the ambient humidity is higher than setting humidity www.danvex.com...
Page 6
by 3%. Comfort Mode [AU] a. When ambient temperature is lower than 5˚C, compressor will stop working. b. When ambient temperature is higher than 5˚C and lower than 20˚C, the product will set the humidity to 60% automatically. c. When ambient temperature is higher than 20˚C and lower than 27˚C, the product will set the humidity to 55% automatically.
FILTER REMOVAL 1. To remove the filter please press the filter's buckles down, and then remove the filter directly. 2. Wash the filter with cool water (cooler than 40℃) every two weeks, and put filter back after it air-dried naturally. www.danvex.com...
MAINTENANCE INSTRUCTION 1. The unit is not allowed to be placed on surface which is soft or not flat to avoid the unit cause noise, vibration, and water or electricity leakage when operating. 2. Never insert any slim rod or hard stuff into the unit to avoid the damage of the unit. 3.
Page 9
• That capacitors are discharged: this shall be done in a safe manner to avoid possibility of sparking; • That there no live electrical components and wiring are exposed while charging, recovering or purging the system; • That there is continuity of earth bonding. www.danvex.com...
Page 10
REPAIRS TO SEALED COMPONENTS 1. During repairs to sealed components, all electrical supplies shall be disconnected from the equipment being worked upon prior to any removal of sealed covers, etc. If it absolutely necessary to have an electrical supply to equipment during servicing, then a permanently operating form of leak detection shall be located at the most critical point to warn of a potentially hazardous situation.
Page 11
Do not overfill cylinders. (No more than 80 % volume liquid charge). i) Do not exceed the maximum working pressure of the cylinder, even temporarily. j) When the cylinders have been filled correctly and the process completed, make sure that the www.danvex.com...
cylinders and the equipment are removed from site promptly and all isolation valves on the equipment are closed off. k) Recovered refrigerant shall not be charged into another refrigeration system unless it has been cleaned and checked. LABELLING Equipment shall be labelled stating that it has been de-commissioned and emptied of refrigerant. The label shall be dated and signed.