Page 3
Attention!!! These units cannot be used for air cooling!!! Use of DanVex dehumidifier · Despite of windows and doors insulation quality, damp and moisture can penetrate even through thick concrete walls.
Page 4
The ambient air is a gas mixture that always contains a certain amount of water in the form of water vapor. The maximum water vapor content in the air (moisture content of the saturated air) depends on its temperature and pressure. www.danvex.fi...
Page 5
A misted window glass in winter or a misted bottle with a cold drink are common examples of condensing. The higher the relative air humidity the higher is the dew-point temperature, and thus it is easier to fall below the dew-point temperature. www.danvex.fi...
Page 6
Vice versa, the energy is released when gas turns into liquid, such energy is called heat of condensation. The heat generated at condensation and evaporation and is identical. www.danvex.fi...
Page 7
It is prohibited to use the unit for purposes other than intended or not specified in this operations instructions. In case the requirements are not observed our company disclaims any liability and out warranty becomes null and void. Only authorized personnel is permitted to perform works on cooling and electrical system! www.danvex.fi...
Page 8
The water vapor contained in the air deposits as condensate or frost on the evaporator fins in the form of water (frost). Hot heat exchanger Cold heat exchanger (condenser) (evaporator) Dried air Moist air Condensate collection tray Compressor Tank www.danvex.fi...
Page 9
Windows and doors must be closed to prevent free air exchange between the room and ambient atmosphere. · If the unit is used in dust-laden environments it is necessary to take appropriate maintenance measures specially adapted to the particular operation conditions. www.danvex.fi...
Page 10
Part 704 for electric current supply sources equipped with automatic circuit-breakers. If the unit is installed in humid premises such as laundries or cellars it should be equipped with proper automatic circuit-breakers at the buyer's expense. Dehumidifier design (models DanVex DEH-900i and DEH-1200i) Transportation handle Electric cable...
Page 11
Control panel Air filter Grill Connector www.danvex.fi...
Press this button directly to decrease the set humidity. Buzzer buzzes once for each pressing and the set humidity decreases by 1%RH. Successively operation can be achieved by pressing this button successively. Press “Time” button before pressing this button, the time (minute) can be decreases. www.danvex.fi...
Page 13
“preset stop time”. We do not ensure the efficient operation of the unit if the room temperature is below 10 °C and if the relative humidity is below 40 %. www.danvex.fi...
Page 14
When the system detects that humidity sensor exceeds the limited range, the system enters mode of humidity sensor failure. Under this mode, LCD displays humidity failure code“E2”and the system enters continuous dehumidification. c. After temperature /humidity sensor failure is limited, the system works normally. www.danvex.fi...
Page 15
Please connect the power cord firmly with the switch. If the power cord is loose, there may be risk of electric shock. Do not stop operation of dehumidifier by pulling out the power cord. Otherwise fire or electric shock accident may be caused. www.danvex.fi...
Page 16
Water leak 1.The machine is inclined 1.Level the machine 2.Water pipe is blocked 2.Remove blocking object Abnormal noise 1.The machine 1. Place the machine firmly. placed solidly 2. Clear the filter mesh. 2.The filter mesh blocked www.danvex.fi...
Page 17
Specifications DEH-900i DEH-1200i Model 5-32 5-32 Operational temperature range °С 40-95 40-95 Operational humidity range % RH Dehumidification (at 30 °С / 80% RH) l/day 1000 1150 Air capacity m3/hour Internal condensate tank capacity liters R407c/R22 Cooling agent R407c/R22 ~230...
Page 19
The warranty does not cover wearable parts such as filters. The warranty covers the defects in workmanship and materials. During the warranty period DanVex repairs and replaces the part having a defect of material or an manufacturing error. DanVex completely fulfills its warranty obligations when it supplies the Customer a repaired or a spare part.