5.4 Heat exchanger ............................9 5.5 Fan motor ..............................9 5.6 Compressor refrigeration system .......................9 6 DIAGNOSTICS AND TROUBLESHOOTING ....................9 7 DATA SHEET .................................11 8 PERFORMANCE DIAGRAMS ...........................11 9 DIMENSIONS ................................12 10 CIRCUIT DIAGRAM ............................13 SAVE THIS MANUAL FOR FUTURE USES www.danvex.com...
Mobile industrial dehumidifiers DEH-500i / DEH-900i / DEH-1200i DEH-900i/1200i FOREWORD Purpose This user manual has been compiled to provide information about the equipment you have purchased and how to use it safely. Content The manual contains general information about safety and applications, operating principle, control of the drying process, maintenance standards, diagnostics and troubleshooting.
• empty the condensate container on time (when used); • do not use the equipment if there is a suspected malfunction; • do not allow warning signs on the device to be removed; • keep this manual near the dehumidifier. www.danvex.com...
The display can show current and adjustable parameters, operating modes, as well as service information in cases of a malfunction. During operation, continuous repeated air circulation occurs through the dehumidifier and its humidity in the room gradually decreases. www.danvex.com...
Behind the removable panel of the front lower part of the case there is a tank for collecting condensate. On the front upper part of the case there is an incoming air filter, which is fixed with a removable grille. The dehumidifier is equipped with tubeless wheels and a transport handle for easy movement. www.danvex.com...
The panel contains waterproof control buttons and an LCD display. The buttons are used to turn the dehumidifier on/off, set the desired humidity level, and also control the timer. The display shows operating modes, the level of required humidity and current air parameters at the location where the dehumidifier is installed. www.danvex.com...
"-" to adjust the set value. Each key press will be accompanied by a beep sound and the set time will increase or decrease by "1" H. After holding continuously for 2 seconds, the set time can be continuously increased or decreased (setting range: 0-24 hours, default 0 hours). www.danvex.com...
The frequency of maintenance depends on the operating conditions of the dehumidifier. In this way, the maintenance cycle can be determined based on actual operation. Incomplete and incorrect maintenance may reduce the effectiveness of the dehumidifier or cause it to break down. www.danvex.com...
(the display is • check the message on the display • heat exchanger freezing illuminated) and wait for defrosting • humidity sensor is faulty • check the display for errors • fan motor is faulty • check fan rotation www.danvex.com...
Page 11
• Е5 - high refrigerant temperature in the system • E7 - the working current of the compressor is too high Operating a dehumidifier with a clogged filter or heat exchanger will lead to overheating of the compressor and failure, which is not a warranty case! www.danvex.com...
7. DATA SHEET Model DEH-500i DEH-900i DEH-1200i Capacity (at 30°С/80%RH), l/day Operating temperature range, °С +5 .. +32 Humidity range, RH% 40 .. 95 Process air flow, m3/h 1400 Condensate tank capacity, liter Direct drainage Drain water pump Current, A...