Contents: Technical data and functional survey Installation Filling and flushing the system Draining the systém Non-return valve Safety device Expansion tank connection set Solar pump group with integrated Controller The delivery involves: ® DeltaSol ® or DeltaSol BS Pro Controller •...
Installation wall mounting ball valve with integrated non-return valve insulation - rear side (wrench-operated) Controller security-head piece with filling valve insulation - front side 10 - solar manometer 0-6 bar pipe screw joints (not included) 11 - solar manual air discharge valve flush valve (emptying valve) with 12 - solar safety valve...
Filling and flushing the system • Connect the inlet hose to the filling valve under the safety valve and open the valve completely. • Connect the outlet hose to the emptying valve at the flowmeter and open the valve completely. •...
Draining the system • Open the non-return valve in the ball valve above the pump (see the following advice). • Open the air vent at the highest point of the system (above the collectors). • Open the emptying valve at the lowest point of the system, if possible close by the store connection, or at the flush valve and pump.