FlowCon B Installation Operation Commissioning...
Page 2
Technical data and operation Installation Mounting the pump station Integration of DeltaSol® B Cotroller Filling and flushing the system Draining the system Emptying the system by a filling pump Commissioning / Working mode Non-return valves Expansion tank connection set Solar pump group enabling to integrate a Controller •...
Page 3
Installation 1 - Mounting holes 2 - Manometer 3 - Ball valve with non-return valve and dial thermometer 4 - Ball valve and flowmeter 5 - Full empty valve 6 - Full empty valve 7 - Air separator with manual discharge (only FlowCon BL) Mounting the pump group •...
Page 4
® Integration of the Controller DeltaSol front insulation jacket rear insulation jacket front view rear view • Take off the front insulation jacket, starting from the top (hold the thermometers). • Pull the part with controller recess downwards. • Insert the Controller into the provided recess of the insulation and fix it by the fastening screws (3 x 30) and large washers.
Page 5
Draining the system 1. Open both non-return valves in the ball valves (3) by using a wrench 14 for opening halfway the ball valve (see non-return valves). 2. Fit a drain cock at the lowest point of the system. 3. Open all air vents at the collector in order to let air into the system and the collectors to drain.
Page 6
Expansion tank connection set The expansion tank connection set consists of a stainless-steel corrugated pipe 0.5m long with cap nuts on both ends, flat gaskets and connection screw joints for solar expansion tank, and a mount strut for connecting an expansion tank.
Page 7
Quantity: Tel: Rubber stamp print and signature of the seller: Date: Rubber stamp print and signature of the installer: Regulus spol. s r.o. Tel.: +420 241 765 191 Do Koutů 1897/3 Fax: +420 241 763 976 143 00 Praha 4 e-mail: sales@regulus.cz...