Example: Ssi Use In Notification E-Mails; Ssi Use In An Ipl's Web Page - Extron electronics IP Link IPL 250 Reference Manual

Ethernet controller
Table of Contents

Advertisement

Special Applications, cont'd

Example: SSI use in notification e-mails

One simple way to use host SSI commands is to customize e-mail messages that the
IPL 250 sends in response to a monitored condition or event. In the example shown
below, the disconnection e-mail uses SSIs to insert the unit name, IP address, and
time into an e-mail that is sent when the IPL 250 detects that a device attached to it
has been disconnected or when a switch connected to a contact input port closes or
opens. For more information on commands, see the
SIS commands
How these commands are typed into the Global Configurator Email Manager:
1
2
3
Resulting e-mail that is sent out upon equipment disconnection:
1
<!--#echo var="W CN|"-->
results: unit name.
3
<!--#echo var="W CT|"-->
results: date and time.

SSI use in an IPL's Web page

Reference notes:
An __.shtml file can be uploaded to the IPL 250 by using one of the following:
• the File Management tab of the factory embedded Web page
(http://<unit's IP address>/nortxe_index.html)
• an SIS command (see "File streaming commands" in the SIS tables in chapter 4)
5-4
IPL 250 • Special Applications
in chapter 4.
|
WCN
is the
SIS command
to read the IPL's
unit name.
|
WCI
is the SIS
command to
read the IPL's IP
address.
|
WCT
is the
SIS command
to read the date
and time.
Command/response table for
2
<!--#echo var="W CI|"-->
results: unit's IP address.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IP Link IPL 250 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Table of Contents