Panel operations

Scene ("1. Scene")

Here's how to recall or store scenes for a specified amplifier.
■ Recalling a scene ("1. Scene" ➝ "Recall")
Recalls a scene for the specified amplifier.
Parameter
Amp ID
Attributes of the
scene
Scene No.
• If you select "ALL" as the Amp ID, the scene name will not be displayed.
NOTE
• If you select "ALL" as the Amp ID, amplifiers for which there is no correspondingly-numbered scene data will not recall a
scene; they will retain their previous state.
• Scene number 00 is for returning the amplifiers to their default settings.
• If characters not supported by the ACD1 were used for the scene name in Amp Editor, the corresponding locations will
be shown as "~." For details on the characters supported by the ACD1, refer to
the end of this manual.
• Scene names that can be displayed by the ACD1 are a maximum of 12 characters. If a scene name of 13 characters or
longer is specified in Amp Editor, the ACD1 will not display the thirteenth and subsequent character.
• If you edit a parameter after recalling a scene, the E symbol (edit symbol) will be shown in screens that show the scene
number.
■ Storing a scene ("1. Scene" ➝ "Store")
Stores a scene for the specified amplifier.
Parameter
Amp ID
Attributes of the
scene
Scene No.
Scene name
• If the screen indicates "(scene number):(scene name) Overwrite?", scene data has already been stored in the selected
NOTE
scene. If you want to overwrite the existing data, press the [▲INC/YES] button. If you want to store the settings to a dif-
ferent scene number without overwriting, press the [▼DEC/NO] button, then press the [BACK] button several times,
and re-select the scene number for storing.
• Scene data is saved in the ACD1, not in each amplifier.
• Stored scene data is valid only for the identical model of amplifier. Scene data will be ignored if a different model of ampli-
fier is connected with the same Amp ID.
• When you store a scene, the E symbol shown in screens that indicate the scene number will disappear.
10
ACD1 Reference Manual
Range
00–39, ALL
Selects the ID of the amplifier for which to recall a scene. If you select "ALL," the cor-
respondingly-numbered scene will be recalled for all amplifiers.
Preset scene
A user scene that is protected
A user scene that is not protected
00–49
Selects the scene number to be recalled.
Range
00–39, ALL
Selects the ID of the amplifier for which to store a scene. If you select "ALL," the cur-
rent scene will be stored to the selected scene number of all amplifiers.
Preset scene
A user scene that is protected
A user scene that is not protected
01–49
Selects the scene number to be stored.
See character list at
Enter the name of the scene to store. A maximum of 12 characters can be entered.
the end of this manual