PCB Piezotronics IMI SENSORS EX640B00 Installation And Operating Manual page 95

Intrinsically safe industrial vibration sensor, 4 to 20 ma output, 0 to 0.5 in/sec pk, 3 to 1k hz, top exit, 2-pin conn
Table of Contents

Advertisement

Immunity
EN 61000-4-4:2004
Test
Standards
EN 61000-4-5:2005
EN 61000-4-6:2006
EN 61000-4-8:2001
Test Reports
EMC Reports
Safety Reports
EC Type
ATEX Certification
Examination
Voluntary
Supplemental ATEX Certification
Certification
Notified
Body Name
Notified
Body's
Address
I, the undersigned, hereby declare that the equipment specified above conforms to the above Directive(s) Standard(s)
Place: Depew, NY Date: 03/26/2023
PS053 REV. Q 03/26/2023
Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques -
Electrical fast transient/burst immunity test
Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques -
Surge immunity test
Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques -
Immunity to conducted disturbances, induced by radio-frequency fields
Electromagnetic compatibility (EMC) – Part 4-8: Testing and measurement techniques –
Power frequency magnetic field immunity test
GM29045c
GM29046s
LCIE 05 ATEX 6154 X
Ex ia IIC T4, II 1G
LCIE 05 ATEX 6155 X
Ex nL IIC T4
Ex nA IIC T4 (for EX64xB7y, EXTO64xB7y, and EXRV64xB7y)
Laboratoire Central des Industries Electriques (0081)
FONTENAY-AUX-ROSES (Head Office
33, avenue du Général Leclerc
FR- 92260 Fontenay-aux-Roses
Tel. : + 33 1 40 95 60 60
Fax : + 33 1 40 95 86 56
Signature:
Name:
Wendy Willard
Title:
Regulatory Affairs and Product Certification Specialist
)