PCB Piezotronics IMI SENSORS EX640B00 Installation And Operating Manual page 80

Intrinsically safe industrial vibration sensor, 4 to 20 ma output, 0 to 0.5 in/sec pk, 3 to 1k hz, top exit, 2-pin conn
Table of Contents

Advertisement

CP
CSA
GROUP TM
Models EXT064xB7y Vibration Sensors, input rated 28V dc max, 20mA; suitable for use in Class I, Div. 2 or
Class I, Zone 2 locations, when installed per installation Dwg 28766; Temp Code T4
@
Max Ambient 80 Deg C.
Models EXRV64xB7y Vibration Sensors, input rated 28V dc max, 20mA; suitable for use in Class I, Div. 2 or
Class I, Zone 2 locations, when installed per installation Dwg 28766; Temp Code T4
@
Max Ambient 80 Deg C.
Models CS64xB9y Vibration Sensors, input rated 28V dc max, 20mA; suitable for use in Class I, Div. 2 or Class
I, Zone 2 locations, when installed per installation Dwg 56140; Temp Code T4
@
Max Ambient 80 Deg C.
Notes:
1.
Sensor must be installed in a suitable enclosure, acceptable to the local inspection authority having
jurisdiction.
2.
The "x" in the model code may be a 0 to 9, which denotes variations in frequency response range of the
sensors. The "y" in the model code may be a 0 to 9, which denotes variations in sensor sensitivity.
APPLICABLE REQUIREMENTS
CAN/CSA-C22.2 No. 0-M91
-
General Requirements
Canadian Electrical Code, Part
II
C22.2 No. 142-M1987(R2009)
-
Process Control Equipment
C22.2 No. 213-M1987(R2008)
-
Non-Incendive Electrical Equipment for Use in Class I,
Division 2 Hazardous Locations
UL 916 (4th Ed.)
-
Energy Management Equipment
UL 1604 (31d Ed.)
-
Electrical Equipment for Use in Class I and II, Division
2; Class III Hazardous (Classified) Locations
ANSI/ISA 12.12.01-2000
-
Nonincendive Electrical Equipment for Use in Class I
and II, Division 2 and Class III, Divisions 1 and 2
Hazardous (Classified) Locations
CAN/CSA-E60079-15:02
-
Electrical apparatus for explosive gas atmospheres
-
Part 15: Type of Protection 'n'
ANSI/UL 60079-15:02
-
Electrical apparatus for Explosive Gas Atmospheres
-
Part
15:
Type of Protection "n"
CLASS 2258 04
-
PROCESS CONTROL EQUIPMENT
-
Intrinsically Safe Entity
-
For Hazardous Locations
CLASS 2258 84
-
PROCESS CONTROL EQUIPMENT
-
Intrinsically Safe Entity
-
For Hazardous Locations
-
CERTIFIED TO U.S. STANDARDS
Ex ia IIC; AEx ia IIC; Class I, Div. 1, Groups A, B, C and D; Class II, Div. 1, Groups E, F and G; Class III;
Tamb:
-40C to 121C; Tcode: T3C
Models EXHT(M)64x (with connector or integral cable), Vibration Sensors, input rated 28V dc max, 20mA;
intrinsically safe when installed per installation drawing 71991 (sheet 1);