Summary of Contents for PCB Piezotronics IMI Sensors EX625B21
Page 1
Model EX625B21 ACCELEROMETER Installation and Operating Manual For assistance with the operation of this product, contact the PCB Piezotronics, Inc. Toll-free: 800-959-4464 24-hour SensorLine: 716-684-0001 Fax: 716-684-3823 E-mail: imi@pcb.com Web: www.imi-sensors.com...
Page 2
Assistance is needed to safely operate equipment PCB Piezotronics is an ISO-9001 certified company whose Damage is visible or suspected calibration services are accredited by A2LA to ISO/IEC Equipment fails or malfunctions 17025, with full traceability to SI through N.I.S.T.
Page 3
CAUTION Refers to hazards that could damage the instrument. NOTE Indicates tips, recommendations and important information. The notes simplify processes and contain additional information on particular operating steps. The following symbols may be found on the equipment described in this manual: This symbol on the unit indicates that high voltage may be present.
Page 5
Component Name Hazardous Substances Lead (Pb) Mercury (Hg) Cadmium (Cd) Chromium VI Polybrominated Polybrominated Compounds Biphenyls (PBB) Diphenyl Ethers (Cr(VI)) (PBDE) Housing PCB Board Electrical Connectors Piezoelectric Crystals Epoxy Teflon Electronics Thick Film Substrate Wires Cables Plastic Solder Copper Alloy/Brass This table is prepared in accordance with the provisions of SJ/T 11364.
Page 6
Piezoelectric ICP® Accelerometers Operating Guide Operating Guide with Enclosed Warranty Information 3424 Walden Avenue, Depew, New York 14043-2495 Phone (716) 684-0003 Fax (716) 684-3823 Toll Free Line 1-800-959-4IMI MANUAL NUMBER: 18405 MANUAL REVISION: A ECN NUMBER: 49766...
Page 7
General OPERATING GUIDE for use with PIEZOELECTRIC ICP® ACCELEROMETERS SPECIFICATION SHEET, INSTALLATION DRAWING AND CALIBRATION INFORMATION ENCLOSED IMI ASSUMES NO RESPONSIBILITY FOR DAMAGE CAUSED TO THIS PRODUCT AS A RESULT OF PROCEDURES THAT ARE INCONSISTENT WITH THIS OPERATING GUIDE 1.0 INTRODUCTION Congratulations on the purchase of a quality ICP®...
The environment of the application is a critical input voltage. Also, the diode can be changed to supply consideration during program implementation. The higher currents for driving long cable lengths. Constant sensor chosen must be capable of surviving the wide current diodes, as shown in Figure 3, should be used in range of conditions to which it is subjected;...
MS – Mine Safety Approved Sensors 4.1 STANDARD STUD MOUNT TO – Temperature Output Sensor This mounting technique requires smooth, flat contact surfaces for proper operation and is Note: Not all sensors are available with the optional recommended permanent and/or secure prefixes.
semi-permanent mounting, substitute epoxy or another METHOD 2 – Direct Adhesive Mount type of adhesive. For restrictions of space or for convenience, most sensors STEP 3: Hand-tighten the sensor/mounting stud to the (with the exception of integral stud models) can be machine, then secure the sensor with a torque wrench to adhesive-mounted directly to the machine surface.
Page 11
ICP® accelerometers are internally amplified, two-wire accelerometers. Connections to the sensor require two leads: one for the power and signal, and the other for the common and signal return. Often, coaxial cables are used since only two conductors are needed. Coaxial cables are less expensive.
Page 12
(Equation 1) exceed its maximum temperature specification. For this 10 9 max= 2 reason, do not supply excessive current over short cable runs [ −1 ] or when testing at elevated temperatures. Where, f = maximum frequency (hertz) 5.1 CABLE CONNECTOR PROCEDURE C = cable capacitance (picofarads) Care and attention to installation is essential, as the...
6.0 POWERING the system still does not operate properly, consult All ICP® sensors require constant current excitation an IMI Application Engineer. for proper operation. For this reason only use approved constant-current sources. A typical system Note: Always operate the accelerometer within the schematic is shown in Figure 11.
Periodic recalibration may be required by plants with piezoelectric accelerometers. This method relies on strict certification and traceability requirements. It is a simple comparison to a previously calibrated always recommended that the user has the sensor accelerometer, typically referred to as a reference recalibrated periodically, particularly if the sensor standard, as shown in Figure 12.
ICP® sensors are two-wire sensors. They are powered with a constant current DC source. The power supply is typically 18 to 30 volts DC current limited via a constant current between 2 and 20 mA. Typical battery operated supplies offer 2mA of constant current to extend battery life while Figure 14.
11.0 CUSTOMER SERVICE/WARRANTY IMI, a division of PCB Piezotronics, guarantees Total Customer Satisfaction. If, at any time, for any Figure 18. DC Bias Voltage Measurement reason, you are not completely satisfied with any IMI product, IMI will repair, replace or exchange it at no charge.
Page 18
Model Number Revision: F PRECISION INDUSTRIAL ICP® ACCELEROMETER ECN #: 46537 625B21 Performance ENGLISH OPTIONAL VERSIONS Sensitivity(± 5 %) 100 mV/g 10.2 mV/(m/s²) Optional versions have identical specifications and accessories as listed for the standard model Measurement Range ± 50 g ±...
Page 20
PCB PIEZOTRONICS INC. 3425 WALDEN AVE. DEPEW, NEW YORK 14043 INSTRUCTIONS FOR USE - EX(XX)622yzzz/aaa, EX(XX)623yzzz/aaa, EX(XX)625yzzz/aaa, and EX(XX)628yzzz/aaa Series Model(s) EX(XX)622yzzz/aaa, EX(XX)623yzzz/aaa, EX(XX)625yzzz/aaa, and EX(XX)628yzzz/aaa Series where: (XX) - Represents one or more optional designations including: M – Metric mounting hardware and cable TO –...
Page 21
Repair In the event that equipment becomes damaged or ceases to operate, arrangements should be made to return the equipment to PCB Piezotronics for repair. User servicing or repair is not recommended and, if attempted, may void the factory warranty.
Page 22
3425 Walden Avenue, Depew, New York. Same address, same manufacturing facility. Some of the documentation contained in the Technical File associated with this application is labeled IMI Sensors, A PCB Piezotronics Div. and some is labeled simply PCB Piezotronics. PCB Piezotronics labeled drawing are higher level drawings which are used across multiple divisions, while IMI labeled drawing are specific to IMI models.
Page 23
PCB Piezotronics Inc. claims proprietary rights in REVISIONS the information disclosed hereon. Neither it nor any reproduction thereof will be disclosed to others DESCRIPTION without the written consent of PCB Piezotronics Inc. ADDING HT OPTION 48377 SCHEDULE DRAWING NO MODIFICATIONS PERMITTED...
Page 24
PCB Piezotronics Inc. claims proprietary rights in REVISIONS the information disclosed hereon. Neither it nor any reproduction thereof will be disclosed to others DESCRIPTION without the written consent of PCB Piezotronics Inc. -SEE SHEET 1- SCHEDULE DRAWING NO MODIFICATIONS PERMITTED WITHOUT REFERENCE TO THE...
Page 25
PCB Piezotronics Inc. claims proprietary rights in REVISIONS the information disclosed hereon. Neither it nor any reproduction thereof will be disclosed to others DESCRIPTION without the written consent of PCB Piezotronics Inc. ADDED READOUT DEVICE 46289 SCHEDULE DRAWING NO MODIFICATIONS PERMITTED...
Page 26
PCB Piezotronics Inc. claims proprietary rights in REVISIONS the information disclosed hereon. Neither it nor any reproduction thereof will be disclosed to others DESCRIPTION without the written consent of PCB Piezotronics Inc. -SEE SHEET 1- SCHEDULE DRAWING NO MODIFICATIONS PERMITTED WITHOUT REFERENCE TO THE...
Page 27
PCB Piezotronics Inc. claims proprietary rights in REVISIONS the information disclosed hereon. Neither it nor any reproduction thereof will be disclosed to others DESCRIPTION without the written consent of PCB Piezotronics Inc. -SEE SHEET 1- SCHEDULE DRAWING NO MODIFICATIONS PERMITTED WITHOUT REFERENCE TO THE...
Page 28
PCB Piezotronics Inc. claims proprietary rights in REVISIONS the information disclosed hereon. Neither it nor any reproduction thereof will be disclosed to others DESCRIPTION without the written consent of PCB Piezotronics Inc. -SEE SHEET 1- SCHEDULE DRAWING NO MODIFICATIONS PERMITTED WITHOUT REFERENCE TO THE...
Page 29
Project: 70043520 Date Issued: 2016-12-14 Issued to: Industrial Monitoring Instr. (IMI) A Div. of PCB Piezotronics, Inc. 3425 Walden Ave Depew, New York 14043 Attention: Carrie Termin The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C' and 'US' for Canada and US or with adjacent indicator 'US' for US only or without either indicator for Canada only.
Page 30
Certificate: 1175335 (103164) Master Contract: 184981 Project: 70043520 Date Issued: 2016-12-14 - Model 9100CSA Vibration Sensor, input rated 28V dc max, 20mA; intrinsically safe with entity parameters of: Vmax = 30V, Imax = 200mA, Pmax = 1W, Li = 0, Ci = 1.2 nF; when installed per installation dwg 16157; Temp Code T4 @ Max Ambient 121 - Models AO720CS, AO725CS and AO728CS Vibration Sensors, input rated 28V dc max, 20mA;...
Page 31
Certificate: 1175335 (103164) Master Contract: 184981 Project: 70043520 Date Issued: 2016-12-14 - Models EXHT(XX)622 yzzz/aaa, EXHT(XX)623 yzzz/aaa and EXHT(XX)628 yzzz/aaa Vibration Sensors, input rated 28V dc max, 20mA; intrinsically safe with entity parameters of: Ui (Vmax) = 28V, Ii (Imax) = 93mA, Pi (Pmax) = 1 W, Li = 0, Ci = 6.5 nF (Connector Series);...
Page 32
Certificate: 1175335 (103164) Master Contract: 184981 Project: 70043520 Date Issued: 2016-12-14 CLASS 2258 03 - PROCESS CONTROL EQUIPMENT - Intrinsically Safe and Non-Incendive Systems - For Hazardous Locations CLASS 2258 83 - PROCESS CONTROL EQUIPMENT - Intrinsically Safe and Non-Incendive Systems - For Hazardous Locations - CERTIFIED TO U.S.
Page 33
Certificate: 1175335 (103164) Master Contract: 184981 Project: 70043520 Date Issued: 2016-12-14 Class I, Div. 2, Groups A, B, C and D; Ex nL IIC T3; AEx nA IIC T3 - Models EXHT(XX)622yzzz/aaa, EXHT(XX)623yzzz/aaa and EXHT(XX)628yzzz/aaa, series Vibration Sensors, input rated 28V dc max, 20mA; intrinsically safe with entity parameters of: Ui (Vmax) = 28V, Ii (Imax) = 93mA, Pi (Pmax) = 1 W, Li = 0, Ci = 6.5 nF (Connector Series);...
Page 34
Certificate: 1175335 (103164) Master Contract: 184981 Project: 70043520 Date Issued: 2016-12-14 Models EX(XX)62xyzzz/aaa nomenclature coding: (XX) - Optional designations M – Metric mounting hardware and cable TO – Temperature Output Sensor x – Model number (2, 3, 5 or 8) y –...
Certificate: 1175335 (103164) Master Contract: 184981 Project: 70043520 Date Issued: 2016-12-14 APPLICABLE REQUIREMENTS General Requirements – Canadian Electrical Code, Part CAN/CSA-C22.2 No. 0-M91 C22.2 No. 142-M1987 Process Control Equipment CAN/CSA-C22.2 No. 157-92 Intrinsically Safe and Non-Incendive Equipment for Use in Hazardous Locations UL 913 (7 Ed.) Intrinsically Safe Apparatus and Associated Apparatus...
Page 36
Supplement to Certificate of Compliance Certificate: 1175335 (103164) Master Contract: 184981 The products listed, including the latest revision described below, are eligible to be marked in accordance with the referenced Certificate. Product Certification History Project Date Description 70043520 2016-12-14 Update to report 1175335 to include model EX(M)622B & EXVO(M)622B series which is a revised model of EX622A series.
Need help?
Do you have a question about the IMI Sensors EX625B21 and is the answer not in the manual?