CLEANING

Avoid using any abrasive materials. Wiping the outer casing
with a damp cloth should be sufficient. Some stainless steel
cleaning products may not be suitable for plastic and must
not come in contact with the plastic facia parts. Always
disconnect the electrical supply before cleaning.
NEVER USE A SPRAY JET OR ANY OTHER METHOD WHICH COULD
CAUSE WATER TO ENTER THE ELECTRICAL CHAMBER.

ACCESS INSTRUCTIONS

Access to the service area must only be undertaken
by authorised competent persons with knowledge and
practical experience of the appliance, in particular as far as
safety and hygiene are concerned. Power to the boiler must
be disconnected before removing the front panel. Take care
for hot surfaces when working inside the boiler.
Access to the internals of the machine is gained by the removal of the
front panel. Remove the screw underneath the front panel and pull the
bottom of the panel out and over the tap moulding to remove.