Page 1
TECP-96-101 Issue 3 January 2017 FDH 3000 288 Termination Cross-Connect Cabinet User Manual 21356-C FDH 3000 00001777660 Rev B www.commscope.com...
Page 2
Contents herein are current as of the date of publication. CommScope reserves the right to change the contents without prior notice. In no event shall CommScope be liable for any damages resulting from loss of data, loss of use, or loss of profits and CommScope further disclaims any and all liability for indirect, incidental, special, consequential or other similar damages.
TECP-96-101 • Issue 3 • January 2017 • Preface ABOUT THIS MANUAL This publication describes the FDH 3000 288 Termination Cross-Connect Cabinet. Also included are procedures for mounting the cabinet, installing additional connector panels, routing patch cords between the terminated feeder and distribution cables, and replacing damaged components.
1 DESCRIPTION FDH 3000 288 Termination Cross-Connect Cabinet The FDH 3000 288 termination cross-connect cabinet is a secure, above-ground, outdoor fiber optic distribution cabinet that provides cross-connect capability within Fiber To The Premises (FTTP) optical networks. The current version of the cabinet is designed for pedestal-mount applications.
Page 8
TECP-96-101 • Issue 3 • January 2017 The interior of the FDH 3000 288 termination cross-connect cabinet consists of the following primary components: Connector Panels: Provide a point for accessing and cross-connecting network cable optical fibers. Each panel provides mounting spaces for 72 bulkhead adapters. The cabinet may be equipped with one, two, three, or four connector panels.
Page 9
TECP-96-101 • Issue 3 • January 2017 Table 1. FDH 3000 288 Termination Cross-Connect Cabinet Specifications, continued PARAMETER SPECIFICATION Optical port adapters/connectors UPC/SC or APC/SC, Feeder/Distribution cable length 100 ft. 18.3 IN. (46.5 CM) 27.08 IN. (68.8 CM) 35.95 IN.
This section provides general installation considerations, unpacking and inspection procedures, and lists the tools and materials required for cabinet installation. Installation Overview Installation of the FDH 3000 288 termination cross-connect cabinet involves the following main tasks: Installing a Support Base (Pedestal-Mount) – The pedestal-mount cabinet must be mounted on a suitable support base.
• Hole saw and drill (use to cut holes for cable conduit if pre-drilled holes are not usable) • Landscaping equipment and site restoration supplies Concrete Pad Installation • Pad Mount Frame kit for FDH 3000 288 termination cross-connect cabinet (FD3-PMFE06) • 9/16-inch wrench • Security key (accessory - required to remove lifting eyes) •...
Page 17
WIRE 21512-C Figure 5. Mounting the FDH 3000 288 Termination Cross-Connect Cabinet on the FMS Use the following procedure to mount the cabinet on the FMS: 1. Use a 3/16-inch security hex-head wrench to remove the four screws that secure...
Page 22
4.0 IN. MIN. (10.2 CM) 21644-A Figure 9. Constructing the Concrete Pad for the FDH 3000 288 Termination Cross- Connect Cabinet A template is provided with the cabinet isolation gasket. The template may be used to determine the cable conduit locations. Place the template over the top of the PMF and...
TECP-96-101 • Issue 3 • January 2017 5 OSP CABLE CONFIGURATION INFORMATION The FDH 3000 288 termination cross-connect cabinet is equipped with pre-installed OSP cables. The cables may be designated as feeder or distribution cables depending on the application requirements. The cable stub ends must be spliced to the network cables at a separate splice enclosure (not provided).
TECP-96-101 • Issue 3 • January 2017 6 CONNECTOR PANEL INSTALLATION The FDH 3000 288 termination cross-connect cabinet can support up to four 72- position connector panels. Cabinets can be ordered with 1, 2, 3, or 4 connector panels pre-installed in the cabinet. If the cabinet is equipped with less than four connector panels, additional panels may be installed as needed.
TECP-96-101 • Issue 3 • January 2017 8 MAINTENANCE AND REPAIR PROCEDURES The FDH 3000 288 termination cross-connect cabinet requires no regular maintenance to insure continuous and satisfactory operation. Maintenance is limited to repairing or replacing any cabinet components that may be damaged or broken in the course of normal operation.
10. Reinstall the two locking nuts (saved in step 2) that secure the grounding strap lug to the door. 11. Repeat process for the left door. 12. Close doors and check for proper operation. 9 CUSTOMER INFORMATION AND ASSISTANCE http://www.commscope.com/SupportCenter/TechnicalSupport.aspx Page 32...