  • Page 1 3A17 3A33 Single Axis Knee Joint 3A17 3A33 3A17/E100 Instructions for Use...
  • Page 2 Gebrauchsanweisung Monozentrisches Kniegelenk ........ 5 Instructions for Use Single Axis Knee Joint ..........8 Instrucciones de uso Rodilla monocéntrica ........... 11 2/16...
  • Page 3 50 % 50 % 5° 10 – 15 mm 3/16...
  • Page 4 4/16...
  • Page 5 Körpergewicht: 150 kg 125 kg Die 3A17 und 3A33 Monozentrischen Kniegelenke (nachfolgend als „das Produkt“ bezeichnet) sind für die Mobilitätsklasse 1 und bis zu einem maximalen Körpergewicht, einschließlich getragener und gestützter Lasten, siehe Tabelle, zugelassen und nicht für sportliche Aktivitäten (z. B. Springen, Laufen u. ä.) geeignet.
  • Page 6: Technische Hinweise

    Bauteilen Fett entzieht und es somit zu Funktionsstörungen kommen kann. Bei Einsatz des Produkts unter Verwendung von Talkum erlöschen alle Ansprüche gegen die Streifeneder ortho.production GmbH. Silikon-Trennspray direkt auf die Reibflächen in der Schaumkosmetik sprühen. Bei der Verwendung einer Schaumkosmetik ist darüber hinaus darauf zu achten, dass diese sich nicht zwischen den beweglichen Teilen des Kniegelenks verklemmt, da dies zum Sturz führen kann.
  • Page 7: Wartung Und Service

    Metallflächen des Kniegelenks empfehlen wir das Gelenkfett Schmiermittel. Bei Funktionsstörungen ist das Produkt zur Wartung einzusenden. Konformitätserklärung „ Die Streifeneder ortho.production GmbH erklärt als Hersteller in alleiniger Verantwortung, dass das Produkt den Anforderungen der Verordnung (EU) 2017/745 für Medizinprodukte (MDR) entspricht. 7/16...
  • Page 8 150 kg 125 kg The 3A17 and 3A33 Single Axis Knee Joints (hereinafter referred to as „the product“) are approved for activity level 1 according to Streifeneder walky-system and for a maximum body weight, including carried and supported loads, see chart, and are not suitable for sporting activities like jumping, running, etc.
  • Page 9 If the product is used with talcum powder, all claims against Streifeneder ortho.production are null and void. Spray the Silicone Parting Agent Spray directly onto the friction surfaces of the cosmetic soft foam cover.
  • Page 10: Declaration Of Conformity

    In the event of malfunctions, the product must be sent in for maintenance. Declaration of Conformity „ Streifeneder ortho.production GmbH declares as manufacturer in sole responsibility, that the product complies with the Regulation (EU) 2017/745 for medical devices (MDR). 10/16...
  • Page 11 150 kg 125 kg Las rodillas monocéntricas 3A17 y 3A33 (denominadas en lo sucesivo «el producto») están homologadas para pacientes con grado de movilidad 1 y hasta un peso corporal máximo, incluyendo cargas adicionales y sujetadas, ver cuadro, y no son adecuadas para actividades deportivas (por ejemplo, saltar, correr, etc.).
  • Page 12: Especificaciones Técnicas

    ¡Este producto no debe exponerse a medios químicos y medios que promuevan corrosión como: agua dulce y salada, ácidos, polvo o arena! En caso de incumplimiento de las disposiciones legales, se extinguirán todos los derechos de indemnización contra Streifeneder ortho.production GmbH. ¡Por favor, informen a sus pacientes! 12/16...
  • Page 13: Montaje

    Con el uso de talco aumenta el riesgo de caída, ya que este absorbe la grasa de los componentes mecánicos y pueden producir trastornos funcionales. Si se utiliza el producto aplicando talco, Streifeneder ortho.production GmbH no se responsabiliza de los daños producidos. Aplique el spray de silicona directamente sobre la superficie de fricción de la espuma cosmética.
  • Page 14 14/16...
  • Page 15 15/16...
  • Page 16 *) Body mass limit not be exceeded (maximum body weight including carried or supported loads)! For further details see manufacturer‘s written instructions on intended use! © copyright Streifeneder ortho.production 3A17/G V002 2024-02 Streifeneder ortho.production GmbH Moosfeldstraße 10 · 82275 Emmering/Germany T +49 8141 6106-0 ·...