Ph - High/Low Alarm; Ph - Pump-Stop Alarm - Astralpool Control Connect-PH/ORP line Instruction Manual

Control panel for swimming pools
Table of Contents

Advertisement

25.3 pH - High/low alarm

4.10
100%
pH
FLOW OK
LOW pH
pH
pH<6.0
7.10
9.10
LOW
100%
HIGH
pH
FLOW OK
HIGH pH
pH>8.5
25.4 pH – PUMP-STOP alarm
9.99
100%
pH
pH
7.10
FLOW OK
pH 6.0–9.0
Reset the PUMP-STOP alarm.
After resetting the PUMP-STOP alarm, the pump will restart if the pH value is above (0.2) of the setpoint and is below 9.0.
pH
7.35
pH
9.99
123
ClmV
720
720
25.2
FLOW
OK
°C
12:15
PUMP-STOP Function Configuration.
ON – OFF.
Value 0...120min.
pH
7.35
pH
7.35
7.30
123
ClmV
720
720
25.2
FLOW
OK
°C
12:15
- Low and high alarms appear if the reading is outside the set values. These values cannot
PS 60m
INTEL
be modified.
HYS 2s
35 h
If the high pH alarm appears, the pH pump will be switched off according to the safety
values set.
FUSE OK
PS 60m
INTEL
Standard mode
HYS 2s
pH > 8.5 = PH HIGH ALARM = Pump off
35 h
pH < 6.5 LOW PH ALARM
FUSE OK
Biopool mode
pH > 9.0 = HIGH PH ALARM = Pump off
pH < 6.0 LOW PH ALARM
The pH of the pool must be manually reduced to 8.45 (standard mode) or 8.95
(biopool mode) for the pump to start dosing again.
- The integrated pH has a safety system (PUMP-STOP) that acts on the dosing pump and
INTEL
prevents the following situations.
HYS 2s
35 h
- Damage caused by dry running of the pump (depleted pH-minus product).
- Overdosage of pH-minus product (damaged or aged sensor).
FUSE OK
- pH regulation problems due to high alkalinity of the water (freshly filled pool, high carbo-
nate levels).
- When the PUMP-STOP FUNCTION is activated (default), the system stops the dosing
pump after a programmed time without having reached the pH setpoint.
The PUMP-STOP FUNCTION is factory set to 60 minutes.
Clppm
Sens
Clppm
Sens
pH
7.35
8.98
100%
pH
HYS 2s
FLOW OK
pH: 6.0–9.0
CAL
Sens
Clppm
Sens
pH
Clppm
7.35
8.98
P.S 60m
100%
pH
HYS 2s
FLOW OK
pH: 6.0–9.0
CAL
Clppm
Sens
pH
RESET P.STOP
7.35
YES
NO
8.98
P.STOP
P.STOP
INTEL
INTEL
100%
pH
HYS 2s
0 h
FLOW OK
0 h
pH: 6.0–9.0
FUSE OK
FUSE OK
CAL
Sens
pH
Clppm
/Config
Mode
AUTO
pH+/pH-
pH-
INTEL
% Pump
100
0 h
Pump Stop
60
FUSE OK
55
Sens
pH
Clppm
/Config
Pump Stop
Mode
AUTO
On
Off
pH+/pH-
pH-
% Pump
100
120
Pump Stop
60
SAVE